hopf 4465AC User manual

_____________________________________________________________
Additional Technical Manual
for DIN Rail Modules
4465AC/4475AC/4800AC/6870AC/6875AC
with
AC Power Supply
Type AC-M05-D / AC-M10-D
ENGLISH
Version: 01.03
-
17.06.2021
_____________________________________________________________
Industriefunkuhren

2 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•

INPORTANT NOTES
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 3 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
Downloading Technical Descriptions
All current descriptions of our products are available free of charge via our homepage on the
Internet.
Homepage: http://www.hopf.com
E-Mail: [email protected]
Symbols and Characters
Operational Reliability
Disregard may cause damages to persons or material.
Functionality
Disregard may impact function of system/device.
Information
Notes and Information.

SERVICE RELIABILITY
4 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
Safety regulations
The safety regulations and observance of the technical data serve to
ensure trouble-free operation of the device and protection of persons and
material. It is therefore of utmost importance to observe and compliance
with these regulations.
If these are not complied with, then no claims may be made under the
terms of the warranty and no liability will be assumed for any ensuing
damage.
Safety of the device
This device has been manufactured in accordance with the latest
technological standards and approved safety regulations
The device should only be put into operation by trained and qualified staff.
Care must be taken that all cable connections are laid and fixed in
position correctly. The device should only be operated with the voltage
supply indicated on the identification label.
The device should only be operated by qualified staff or employees who
have received specific instruction.
If a device must be opened for repair, this should only be carried out by
employees with appropriate qualifications or by
hopf
Elektronik GmbH.
Before a device is opened or a fuse is changed all power supplies must
be disconnected.
If there are reasons to believe that the operational safety can no longer be
guaranteed the device must be taken out of service and labeled
accordingly.
The safety may be impaired when the device does not operate properly or
if it is obviously damaged.
CE-Conformity
This device fulfils the requirements of the EU directive 2014/30/EU
"Electromagnetic Compatibility" and 2014/35/EU "Low Voltage Equipment".
Therefore the device bears the CE identification marking
(CE = Communautés Européennes = European communities)
The CE indicates to the controlling bodies that the product complies with the requirements of
the EU directive - especially with regard to protection of health and safety for the operator
and the user - and may be released for sale within the common markets.

TABLE OF CONTENTS
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 5 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
Contents Page
1Variations to Standard Manuals of the Devices..........................................................7
2Housing Installation......................................................................................................8
2.1 Mounting ...................................................................................................................8
2.2 Demounting...............................................................................................................8
3Power Supply................................................................................................................9
3.1 Power Supply Unit Specifications..............................................................................9
3.2 Safety and Warning Instructions..............................................................................10
3.3 Power Connection and Control Display ...................................................................11
3.3.1 Connection to Several Power Networks ............................................................................ 11
3.3.2 Connection of the Power Cable ......................................................................................... 11
3.3.3 Voltage Input / Fuse Protection.......................................................................................... 12
3.3.4 Power LED......................................................................................................................... 12
4Technical Data ............................................................................................................13
4.1 General ...................................................................................................................13
4.2 Power Supply
hopf
DIN Rail Module......................................................................13
4.3 Power Supply..........................................................................................................13
4.4 Dimensions –Rail Mounting Housing......................................................................14

TABLE OF CONTENTS
6 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•

VARIATIONS TO STANDARD MANUALS OF THE DEVICES
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 7 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
1 Variations to Standard Manuals of the Devices
This additional manual is valid for the
DIN Rail Modules 4465AC, 4475AC, 4800AC, 6870AC and 6875AC
with AC power supply AC-M05-D or AC power supply AC-M10-D.
This manual only contains the specification for the voltage supply for the
different modules and replaces the technical specifications of the according
manuals for those devices.
Changes in comparison to the standard with DC voltage input:
•The voltage input via the connector X1 is not applicable. The upper two screws of
the screw terminal of X1 have no function (n.c. –not connected).
•The dimension of the housing changes from Type 1 to Type 2
(dimensions see chapter 4.4 Dimensions –Rail Mounting Housing).
•The AC voltage input is made via the 3-pole pluggable screw terminal labeled with L,
N and PE. The nominal input voltage is 85-264VAC.
•The earthing of the DIN Rail Module is made via the PE contact of the 3-pole
pluggable screw terminal.
Example: DIN Rail Module 6875AC with AC Power Supply AC-M10-D

HOUSING INSTALLATION
8 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
2 Housing Installation
The DIN Rail Module can be clipped on to all DIN rails per DIN EN 50 022 and is designed
for horizontal mounting.
Installation dimensions
The dimensions of the housing can be found in Chapter 4.4 Dimensions –Rail Mounting
Housing.
•4465AC with integrated AC power supply Housing TYPE 2
•4475AC with integrated AC power supply Housing TYPE 2
•4800AC with integrated AC power supply Housing TYPE 2
•6870AC with integrated AC power supply Housing TYPE 2
•6875AC with integrated AC power supply Housing TYPE 2
In order to guarantee satisfactory convection we recommend the following
minimum distance from other modules:
•5.0 cm in a vertical direction
•1.0 cm in a horizontal direction
2.1 Mounting
Place the rail guide bar of the module against the lower edge of the DIN rail, push the
module upwards and clip into place at the top.
2.2 Demounting
Push the module upwards and then tip forward to remove from the DIN rail.

POWER SUPPLY
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 9 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
3 Power Supply
The DIN Rail Module has an AC power supply unit with a wide input range.
3.1 Power Supply Unit Specifications
Internal
Power Supply
(Only wide input range)
hopf
Type: AC-M05-D
hopf
Type: AC-M10-D
Input Data
Input voltage range
85-264VAC
100-250VDC
85-264VAC
100-250VDC
Frequency
47-440Hz
0 Hz
47-440Hz
0 Hz
Current consumption (at nominal
values)
approx. 0.15A (100VAC)
0.10A (200VAC)
approx. 0.30A (100VAC)
0.20A (200VAC)
Inrush current
typ. 15A (IO= 100%) 100VAC
typ. 30A (IO= 100%) 200VAC
typ. 15A (IO= 100%) 100VAC
typ. 30A (IO= 100%) 200VAC
Hold-up time at nominal laod
> 20msec. (> 100VAC)
> 20msec. (> 100VAC)
Start-up time after connected
mains voltage
< 1 sec.
< 1 sec.
Transient overvoltage protection
Overvoltage protection III
(EN 60664-1)
Overvoltage protection III
(EN 60664-1)
Protection supply, internal
400 mA slow blow (device
protection)
400 mA slow blow (device
protection)
Recommended back-up fuse
(AC)
Circuit breaker 6A, 10A
charakteristics B (EN 60898)
Circuit breaker 6A, 10A
charakteristics B (EN 60898)
Leakage current against PE
< 0.5mA (60Hz, according to
EN 60950)
< 0.5mA (60Hz, according to
EN 60950)
Input isolation voltage / PE
2000VAC, 1 minute,
leakage current = 10mA,
500VDC, 50MOhm min.
(at room temperature)
2000VAC, 1 minute,
leakage current = 10mA,
500VDC, 50MOhm min.
(at room temperature)
Output Data (only internal)
Internal nominal output voltage
5VDC
5VDC
Nominl output current
IN0° C ... +55° C
1A (UOUT = 5VDC)
2A (UOUT = 5VDC)
Efficiency
> 77%
> 74%
Function Display (Power LED)
LED green
LED green

POWER SUPPLY
10 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
3.2 Safety and Warning Instructions
Please read these instructions thoroughly to facilitate safe operation of the equipment and to
use all of its functions.
Warning: Never work on live equipment on open devices! Danger to life!
The
hopf
DIN Rail Module is a built-in device. It is protected for installation in service
access areas. Installation and commissioning may only be carried out by suitable specialist
personnel. In doing so the respective country-specific regulations (e.g. VDE, DIN) are to be
observed.
In particular, before commissioning please ensure that:
•The power connection has been installed correctly and there is guaranteed
protection against electric shock!
•The device can be switched off externally to the power supply, in accordance with
the provisions of EN 60950 (e.g. via the primary-side line protection)!
•The ground wire is connected!
•All power cables are correctly fused and sized!
•All output lines are sized in accordance with the max. output current of the device or
are specially fused!
•Sufficient convection is guaranteed!
The housing can become very hot dependent on the environment temperature and the load
on the device!
The device contains components with life-threatening voltage and a high amount of stored
energy!

POWER SUPPLY
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 11 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
3.3 Power Connection and Control Display
Connection and operation of the
hopf
DIN Rail Module power supply.
3.3.1 Connection to Several Power Networks
3.3.2 Connection of the Power Cable
The power cable is connected via a 3pole pluggable screw terminal. The following cable
cross-sections can be connected to the input plug:
Fixed
[mm2]
Flexible
[mm2]
AWG
Starting
moment [Nm]
L, N,
0.2-2.5
0.2-2.5
24-12
0.5 –0.6
For a reliable and secure contact:
Strip the insulation by 8 mm
The connector must always be mounted using the housing and strain relief
fitting provided.

POWER SUPPLY
12 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
3.3.3 Voltage Input / Fuse Protection
The 85-264VAC connection is made via the plug-in screw connections L, N and .
Primary Side Fuse Protection
The device must be installed in accordance with the provisions of EN 60950. There must be
a suitable separating device external to the power supply capable of switching the device off.
The primary side line protection, for example, is suitable for this purpose.
Further equipment protection is not required because the device is fused internally.
Recommended External Fuse
Automatic cut-out 6A or 10A, Characteristic B (or equivalent in function).
A suitable external fuse is required for DC applications.
If the internal fuse trips (device protection) it is highly likely that the device is
faulty. In this case the equipment should be checked at the factory.
3.3.4 Power LED
The green Power LED enables functions to be evaluated on-site at the control cabinet.
LED lights
Normal power supply operation
LED off
No power supply is available or the device is faulty.

TECHNICAL DATA
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03 13 / 14
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
4 Technical Data
4.1 General
The technical data in this document are only valid in connection with the technical manual of
the according module.
All specified data in this document replaces those of the appropriate technical manual of the
module.
Regarding all other articles the technical manual of the module is the relevant document.
4.2 Power Supply
hopf
DIN Rail Module
General Data
Installation position
On horizontal 35mm DIN rail per
DIN EN 50 022
Protection Type of the housing
IP40
Protection Class
I, with PE connection
MTBF
> 300,000h
Type of housing
Aluminium, closed
Dimensions (W x H x D) + DIN Rail
100 x 105 x 130mm (Type 2)
Weight
approx. 1.05kg
Climatic Data
Environmental temperature
Operation
0° C ... +55° C
Storage
-20° C ... +75° C
Humidity
Up to 90% at +25° C, no condensation
CE compliant to EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC
Safety - Low Voltage Directive
DIN EN 60950-1:2001
+ A11 + Corrigendum
EN 61000-6-4:
EMC (Electro-Magnetic Compatibility)
Stability
EN 610000-4-2 /-3/-4/-5/-6/-11
EN 61000-6-2:
EN 61000 -3 -2 /-3
Interference Voltage EN 55022
EN 55022 Class B
Interference Voltage EN 55022
EN 55022 Class B
4.3 Power Supply
Internal Power Supply
(with wide input range)
hopf
type: AC-M05-D /AC-M10-D
Power consumption AC-M05-D
max. 6 VA
Power consumption AC-M10-D
max. 15 VA

TECHNICAL DATA
14 / 14 4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
•
D-58511 Lüdenscheid
•
Tel.: +49 (0)2351 9386-86
•
Fax: +49 (0)2351 9386-93
•
Internet: http://www.hopf.com
•
4.4 Dimensions –Rail Mounting Housing
Clip fastening for
Klammerbefestigung für
35mm Hutschienenmontage (DIN EN 50 022)
35mm rail mounting (DIN EN 50 022)
Front Panel Parts
Front Panel Parts
W
105,00 (4.13")
2,50 (0.10") 2,50 (0.10")
26,80
(1.06") 50,00 (1.97")
105,00 (4.13")
C
L
All dimensions in mm (inch)
Material: Aluminium
TYPE (L) (W) (C)
1
2
3
5
6
ength idth lip
130 64,5 40,0
130 100,0 80,0
130 135,0 80,0
175 100,0 80,0
175 135,0 80,0
(5.12") (2.54") (1.57")
(5.12") (3.94") (3.15")
(5.12") (5.31") (3.15")
(6.89") (2.54") (1.57")
(6.89") (3.94") (3.15")
(6.89") (5.31") (3.15")
4175 64,5 40,0
.
Clip for 35mm DIN rail mounting - Aluminium
Side View
Front View
This manual suits for next models
4
Table of contents
Other hopf Network Hardware manuals
Popular Network Hardware manuals by other brands

Symantec
Symantec NetBackup 5200 Series Quick installation guide

GLOBAL Export Import
GLOBAL Export Import MN8805G5 Basic operation

DPS Telecom
DPS Telecom T/Mon/IAM manual

Intuicom
Intuicom RTK Bridge-X installation guide

INSIGHT
INSIGHT DLP DIRECTOR 1100 Hardware installation guide

INSIGHT
INSIGHT DLP SENSOR 600 Hardware installation guide