Preface
This manual describes operation of the combination type fluoride ion selective
electrode.
Be sure to read this manual before using the product to ensure proper and safe
operation of the product.
Also safely store the manual so it is readily available whenever necessary.
Please contact HORIBA Advanced Techno if any points regarding safety come
to your attention during use.
Product specifications and appearance, as well as the contents of this manual
are subject to change without notice.
Warranty and responsibility
This product is not covered by warranty because it is a consumable item.
HORIBA Advanced Techno Co., Ltd. SHALL NOT BE LIABLE FOR ANY
DAMAGES RESULTING FROM ANY MALFUNCTIONS OF THE
PRODUCT, ANY ERASURE OF DATA, OR ANY OTHER USES OF THE
PRODUCT.
Trademarks
QR Code is a trademark of DENSO WAVE INCORPORATED.
Company names and brand names are either registered trademarks or
trademarks of the respective companies. (R), (TM) symbols may be
omitted in this manual.
Regulations
EU regulations
Conformable standards
This equipment conforms to the following standards:
RoHS: EN50581
9. Monitoring and control instruments
Authorised representative in EU
HORIBA UK Limited
2 Dalston Gardens, Stanmore,
Middx HA7 1BQ, UK

China regulation
标记的意义
Meaning of Marking
产品中有害物质的名称及含量
Name and amount of hazardous substance used in a product
本标记适用在中华人民共和国销售电器电子产品,标记中央的数字表示环
境保护使用期限的年数。(不是表示产品质量保证期间。) 只要遵守这个产
品有关的安全和使用注意事项,从制造日开始算起在这个年限内,不会给环
境污染、人体和财产带来严重的影响。请不要随意废弃本电器电子产品。
This marking is applied to electric and electronic products sold in the
People's Republic of China. The figure at the center of the marking
indicates the environmental protection use period in years. (It does not
indicate a product guarantee period.) It guarantees that the product will
not cause environment pollution nor serious influence on human body and
property within the period of the indicated years which is counted from the
date of manufacture as far as the safety and usage precautions for the
product are observed. Do not throw away this product without any good
reason.
部件名称
Unit name
有害物质
Hazardous substance
铅
Lead
(Pb)
汞
Mercury
(Hg)
镉
Cadmium
(Cd)
六价铬
Hexavalent
chromium
(Cr (VI))
多溴联苯
Polybromo-
biphenyl
(PBB)
多溴二苯醚
Polybromo-
diphenyl ether
(PBDE)
本体
Main unit ×○×○○ ○
电缆
Cable ×○○ ○ ○ ○
本表格依据 SJ/T 11364 的规定编制。
This form is prepared in accordance with SJ/T 11364
○:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求
以下。
Denotes that the amount of the hazardous substance contained in all of the
homogeneous materials used in the component is below the limit on the acceptable
amount stipulated in the GB/T 26572.
×:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限
量要求。
Denotes that the amount of the hazardous substance contained in any of the
homogeneous materials used in the component is above the limit on the acceptable
amount stipulated in the GB/T 26572.

For your safety
Hazard classification and warning symbols
Warning messages are described in the following manner. Read the
messages and follow the instructions carefully.
Hazard classification
Warning symbols
This indicates an imminently hazardous
situation which, if not avoided, will result in
death or serious injury. This is to be limited to
the most extreme situations.
This indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
This indicates a potentially hazardous
situation which, if not avoided, may result in
minor or moderate injury. It may also be used
to alert against unsafe practices.
Description of what should be done, or what should be
followed
Description of what should never be done, or what is
prohibited

Safety precautions
This section provides precautions for using the product safely and correctly
and to prevent injury and damage. The terms of DANGER, WARNING, and
CAUTION indicate the degree of imminency and hazardous situation. Read
the precautions carefully as it contains important safety messages.
Precautions for chemicals
Solutions used for calibration and measurement must not
come in contact with the skin, or consumed.
These solutions stimulate the eyes and skin. If these
solutions come in contact with your skin or eyes, flush
immediately with running water.
If you drink these solutions by accident, immediately seek
medical advice.
When you handle these solutions, make sure to wear latex
gloves, protective glasses, etc.

Product handling information
Operational precautions
Use of the product in a manner not specified by the manufacturer may
impair the protection provided by the product. And it may also reduce
product performance.
Exercise the following precautions:
Use the supplied internal solution for the reference electrode. Using any
other internal solutions may cause measurement errors.
Do not get the electrode connector wet or touch it with dirty hands. It may
cause a failure.
Do not touch a hard surface with the electrode. It may cause a failure.
Only use the product including accessories for their intended purpose.
HORIBA Advanced Techno assumes no liability when they are used for
any other products.
Disposal of the product
When disposing of the product, follow the related laws and/or regulations of
your country.

Manual information
Description in this manual
The following explains the icons used in this manual.
Original language
This is the English translation of an original Japanese document.
Documents related to this product
The following documents are related to this product.
Combination type Fluoride Ion Selective Electrode
Instruction Manual (this manual)
This manual mainly discusses how to operate the combination type fluoride
ion selective electrode.
Meter Instruction Manual
This manual mainly discusses how to operate the meter to which the
combination type fluoride ion selective electrode is connected.
Electrode Stand Instruction Manual
This manual mainly discusses how to operate the electrode stand which
holds the combination type fluoride ion selective electrode.
Icon Meaning
This interprets the necessary points for correct
operation and notifies the important points for
handling the product.
This indicates reference information.
This indicates the part where to refer for
information.
This indicates that you can access the instruction
video on the web page.
Access the webpage by using the QR Code.
Note
Note
TipTip
View videoView video


Before Use 1
Confirmation of the items included in the package . . . . . . . 2
About this product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Measurement procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrode Preparation 9
Assembling the electrode (only when use for first time) . . 10
Filling with internal solution . . . . . . . . . . . . . . . . . . . . . . . . 12
Rinsing the electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connecting the electrode to the meter . . . . . . . . . . . . . . . 17
Calibration 19
Standard solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
TISAB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Calibration operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Measurement 33
Requirements for sample and standard solutions . . . . . . . 34
Measurement hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Measurement units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Measurement operation . . . . . . . . . . . . . . . . . . . . . . . . . . 36
After Measurement 43
Contents

How to clean the electrode . . . . . . . . . . . . . . . . . . . . . . . . 44
Maintenance 49
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Troubleshooting 53
When accurate measurement is not possible . . . . . . . . . . 54
Reference 59
Ion selective electrodes . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Measurement principle of ion selective electrode . . . . . . . 62
Characteristics of fluoride ion selective electrode . . . . . . . 66
Material 73
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
External dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Figures
Fig. 1 Included items . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Fig. 2 System configuration. . . . . . . . . . . . . . . . . . . . . . 3
Fig. 3 Names of parts . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Fig. 4 Structure of combination type
ion selective electrode. . . . . . . . . . . . . . . . . . . . 60
Fig. 5 State of liquid junction of reference electrode . . 61
Fig. 6 Relationship between monovalent cation
concentration (activity) and electrode potential. 63
Fig. 7 Difference in state of solution depending on ion
concentration. . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fig. 8 Calibration curve of fluoride ion
selective electrode . . . . . . . . . . . . . . . . . . . . . . 66
Fig. 9 Impact of pH on fluoride ion selective electrode 67

Tables
Table 1 F-concentration measurement unit conversion
table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 2 Check list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 3 Electrode types . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 4 (Example) Activity coefficient for monovalent ion
concentration . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 5 Relationship between temperature of ion selective
electrode and theoretical slope . . . . . . . . . . . . 68
Table 6 Relationship between
temperature of chloride ion selective electrode
and theoretical slope . . . . . . . . . . . . . . . . . . . . 69
Table 7 Specifications of combination type fluoride ion
selective electrode . . . . . . . . . . . . . . . . . . . . . . 74
Table 8 Consumables . . . . . . . . . . . . . . . . . . . . . . . . . 76

Before Use
B
efore Use
This chapter describes what you should know before using the product.
Confirmation of the items included in
the package ...................................... 2
About this product ........................... 3
Product features...........................................................3
System configuration ...................................................3
Names of parts.............................................................4
Measurement procedure ................. 5

2
Confirmation of the items included
in the package
Open the package and make sure that the following items are included.
Fig. 1 Included items
This product is a consumable item. For details on purchasing an electrode and
reagent, refer to "Consumables" ( page 76).
1000 mg/L standard solution
(50 mL)
100 mg/L standard solution
(50 mL)
Internal solution
(50 mL)
Protective pipe
Instruction
manual
(this document)
Ion electrode tip
TISAB (50 mL, 2 bottles)
Dropper
Main unit
of electrode

3
Before Use
About this product
Product features
The combination type fluoride ion selective electrode is an electrode that
combines a tip type ion electrode with a reference electrode.
This product has the following features.
Ion concentration can be measured with this one electrode. There is no
need to use a pair of an ion selective electrode and reference electrode.
The reference electrode part has a double junction structure. This
minimizes the contamination of the sample solution by the internal
solution outflow, the interference on the electrode potential, and so on.
Since the structure of the liquid junction, movable sleeve type, is capable
of eliminating clogging by contaminants, it is possible to measure the
concentration accurately.
System configuration
This product is used with the meter of HORIBA Advanced Techno
connected, which is sold separately.
Electrode stand(*) is also available.
Fig. 2 System configuration
Refer to the meter instruction manual for more details.
MeterMeter
ElectrodeElectrode
* This stand is optional for the portable meter.
Electrode stand *
Desktop type Portable type

4
Names of parts
This product consists of the parts shown in the figure below.
Fig. 3 Names of parts
* Use the protective pipe for protecting the ion electrode tip.
Attaching it for measurements outdoors will protect the ion electrode tip
against damage from gravel or other foreign matters.
If there is no risk of damage, it is not required to attach it.
Ion selective
membrane
Liquid junction
When the ion electrode tip is
attached
Electrode connector
(BNC connector)
Protective cap
Protective pipe *
Ion electrode tip
Internal solution
fill port
Internal
solution
chamber
Support pipe
Electrode cap
Cable
Rubber cap
(to be removed
before use)

5
Before Use
Measurement procedure
The following figure shows the procedure for measuring the F-concentration.
1Measurement preparation
1
2
4
3
Meter
Fill with internal solution.
( page 12)
Connect the electrode to the meter.
( page 17)
Attach the ion
electrode tip.
( page 10)
Rinse with pure water.
( page 15)

6
2Calibration
Before the first use
Before use after storage for two
weeks or longer
If the electrode is less responsive
3Measurement
In the following cases, perform
conditioning of the electrode before
calibration.
For details on conditioning, refer to
“Conditioning of the electrode”
( page 26).
1
2
Perform calibration.
( page 25)
Prepare two types of
solutions for calibration.
( page 23)
1
2
Prepare the sample solution.
( page 36)
Perform measurement.
( page 37)

8
Table of contents