HP Enterprise ProLiant DL380 Manual

HPE ProLiant DL380 Gen10 Server
Maintenance and Service Guide
Part Number: 868989-001
Published: July 2017
Edition: 1
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage
systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer
equipment and trained in recognizing hazards in products with hazardous energy levels.

Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard
Enterprise products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett
Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use,
or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise
website.
Acknowledgments
Intel® and Xeon® are trademarks of Intel Corporation in the United States and other countries.
Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.

Contents
Illustrated parts catalog.............................................................................. 7
Mechanical components......................................................................................................................7
Air baffle spare part.................................................................................................................. 8
Access panel spare parts......................................................................................................... 8
Tertiary PCI riser cage spare part............................................................................................. 8
Primary and secondary PCI riser cage spare part....................................................................8
Chassis ears spare parts..........................................................................................................8
Fan cage spare part..................................................................................................................9
2U bezel spare part.................................................................................................................. 9
Rail kit spare parts....................................................................................................................9
Miscellaneous blanks kits spare parts...................................................................................... 9
System components..........................................................................................................................10
DIMM spare parts................................................................................................................... 12
Processor spare parts.............................................................................................................12
Heatsink spare parts...............................................................................................................14
Power supply spare parts....................................................................................................... 14
Controller spare parts............................................................................................................. 14
PCI riser board spare parts.....................................................................................................15
FlexibleLOM adapter spare parts........................................................................................... 16
System board spare part........................................................................................................ 16
System battery spare part.......................................................................................................16
Server options................................................................................................................................... 16
Drive spare parts.................................................................................................................... 18
Fan spare parts.......................................................................................................................21
Backplane board spare parts..................................................................................................22
Chassis Intrusion Detection Switch spare part....................................................................... 22
GPU options spare parts........................................................................................................ 22
Rear serial port interface spare part....................................................................................... 22
HPE 12Gb DL380 Gen10 SAS Expander Card spare part.....................................................23
HPE Smart Storage Battery spare parts.................................................................................23
Power module spare parts......................................................................................................23
LFF I/O UID spare parts......................................................................................................... 23
HPE Trusted Platform Module 2.0 spare part.........................................................................23
Cable spare parts................................................................................................................... 23
Thermal grease spare parts....................................................................................................24
Customer self repair..................................................................................25
Removal and replacement procedures....................................................35
Required tools................................................................................................................................... 35
Safety considerations........................................................................................................................ 35
Preventing electrostatic discharge..........................................................................................35
Symbols on equipment........................................................................................................... 35
Server warnings and cautions................................................................................................ 36
Preparation procedures.....................................................................................................................36
Power down the server ..........................................................................................................36
Extend the server from the rack..............................................................................................37
Remove the server from the rack........................................................................................... 37
Contents 3

Access the product rear panel................................................................................................38
Accessing the Systems Insight Display.................................................................................. 38
Remove the access panel...................................................................................................... 39
Release the full-length expansion board retainer................................................................... 39
Removing and replacing a drive blank.............................................................................................. 40
Removing and replacing drives......................................................................................................... 40
Removing and replacing a hot-plug drive............................................................................... 40
Removing and replacing an NVMe drive................................................................................ 41
Removing and replacing an M.2 SSD.....................................................................................41
Removing and replacing the hot-plug fan..........................................................................................42
Removing and replacing a power supply blank.................................................................................43
Removing and replacing the AC power supply..................................................................................43
Removing the air baffle......................................................................................................................44
Removing and replacing the primary or secondary PCIe riser cages............................................... 45
Removing and replacing the tertiary PCIe riser cage........................................................................ 46
Removing and replacing the PCIe riser blank................................................................................... 47
Removing and replacing the PCIe riser board...................................................................................48
Removing and replacing an expansion slot blank............................................................................. 50
Removing and replacing an expansion board................................................................................... 51
Removing and replacing the fan cage...............................................................................................52
Removing and replacing the FlexibleLOM.........................................................................................53
Removing and replacing the small form factor universal media bay................................................. 53
Removing and replacing the LFF power switch module....................................................................54
Removing and replacing the SFF optical drive..................................................................................55
Removing and replacing the LFF optical drive.................................................................................. 57
Removing and replacing the 8-SFF drive cage................................................................................. 58
Removing and replacing the 8-SFF drive backplane.........................................................................59
Removing and replacing the 2-SFF front drive cage......................................................................... 59
Removing and replacing the 2-SFF rear drive bay and riser cage.................................................... 60
Removing and replacing the 2-SFF drive cage................................................................................. 61
Removing and replacing the 2-SFF rear drive backplane................................................................. 62
Removing and replacing a 4 LFF midplane cage..............................................................................63
Removing and replacing a three-bay LFF rear drive cage................................................................ 64
Removing and replacing the LFF backplane assembly.....................................................................65
Removing and replacing a front LFF drive backplane....................................................................... 65
Removing and replacing the 3-LFF rear drive backplane..................................................................66
Removing and replacing a rear serial port interface (primary/secondary).........................................67
Removing and replacing a rear serial port interface (tertiary riser)................................................... 68
Removing and replacing an SFF power switch module.................................................................... 69
Removing and replacing an LFF chassis ear with power/UID...........................................................70
Removing and replacing an SFF standard chassis ear.....................................................................71
Removing and replacing a GPU enablement board..........................................................................72
Removing and replacing a DIMM...................................................................................................... 73
Removing and replacing the HPE Smart Storage Battery.................................................................74
Removing and replacing the HPE Flexible Smart Array Controller................................................... 75
Removing and replacing the system battery..................................................................................... 76
Removing and replacing the system board....................................................................................... 77
Re-entering the server serial number and product ID.............................................................80
HPE Trusted Platform Module 2.0 Gen10 Option............................................................................. 80
Troubleshooting.........................................................................................81
Troubleshooting resources................................................................................................................ 81
Diagnostic tools.........................................................................................82
4Contents

Product QuickSpecs..........................................................................................................................82
UEFI System Utilities.........................................................................................................................82
Selecting the boot mode ........................................................................................................82
Secure Boot............................................................................................................................83
Launching the Embedded UEFI Shell ....................................................................................83
Intelligent Provisioning.......................................................................................................................84
Intelligent Provisioning operation............................................................................................84
HPE Insight Remote Support............................................................................................................ 84
USB support...................................................................................................................................... 85
External USB functionality...................................................................................................... 85
HPE Smart Storage Administrator.....................................................................................................85
Component identification......................................................................... 87
Front panel components....................................................................................................................87
Front panel LEDs and buttons...........................................................................................................89
UID button functionality...........................................................................................................93
Power fault LEDs....................................................................................................................93
Systems Insight Display LEDs................................................................................................93
Systems Insight Display combined LED descriptions.............................................................94
Rear panel components.................................................................................................................... 96
Rear panel LEDs............................................................................................................................... 97
System board components................................................................................................................98
System maintenance switch descriptions............................................................................... 99
Processor, heatsink, and socket components................................................................................. 100
Drives.............................................................................................................................................. 100
SAS/SATA drive components and LEDs...............................................................................101
NVMe drive components and LEDs......................................................................................102
uFF drive components and LEDs......................................................................................... 102
Fan bay numbering..........................................................................................................................103
Drive box identification.................................................................................................................... 104
Drive bay numbering....................................................................................................................... 105
Drive bay numbering: Smart Array controller........................................................................105
Drive bay numbering: SAS expander................................................................................... 107
Drive bay numbering: NVMe drives...................................................................................... 109
uFF drive bay numbering...................................................................................................... 110
Cabling......................................................................................................111
HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines........................................................111
Cabling diagrams............................................................................................................................. 111
Cable routing: Front 2SFF drive option for SFF....................................................................113
Cable routing: Front 2SFF drive option for LFF.................................................................... 114
Cable routing: Front 2SFF drive options (3 position cable)...................................................115
Cable routing: Front 8SFF drive options............................................................................... 116
Cable routing: Front 8SFF NVMe/SAS premium drive option...............................................118
Cable routing: Front 8SFF NVMe drive options.................................................................... 118
Cable routing: Front 2SFF NVMe drive option for SFF.........................................................120
Cable routing: Front 2SFF NVMe drive option for LFF......................................................... 121
Cable routing: Midplane 4LFF drive option...........................................................................121
Cable routing: Rear 3LFF drive option..................................................................................122
Cable routing: Rear 2SFF drive options............................................................................... 122
Cable routing: HPE 12G SAS Expander to a controller........................................................123
Cable routing: Systems Insight Display................................................................................ 124
Contents 5

Specifications.......................................................................................... 125
Environmental specifications...........................................................................................................125
Mechanical specifications................................................................................................................125
Power supply specifications............................................................................................................ 126
HPE 500W Flex Slot Platinum Hot-plug Power Supply........................................................ 126
HPE 800W Flex Slot Platinum Hot-plug Power Supply........................................................ 127
HPE 800W Flex Slot Titanium Plus Hot-plug Power Supply................................................ 128
HPE 800W Flex Slot Universal Hot-plug Power Supply....................................................... 129
HPE 800W Flex Slot -48VDC Hot-plug Power Supply......................................................... 130
HPE 1600W Flex Slot Platinum Hot Plug Power Supply...................................................... 131
Acronyms and abbreviations................................................................. 132
Documentation feedback........................................................................ 134
6Contents

Illustrated parts catalog
Mechanical components
Hewlett Packard Enterprise continually improves and changes product parts. For complete and current
supported parts information, see the Hewlett Packard Enterprise PartSurfer website.
Item Description
1Air baffle spare part on page 8
2Access panel spare parts on page 8
3Tertiary PCI riser cage spare part on page 8
4Primary and secondary PCI riser cage spare part
on page 8
5Chassis ears spare parts on page 8
6Fan cage spare part on page 9
72U bezel spare part on page 9*
8Rail kit spare parts on page 9*
9Miscellaneous blanks kits spare parts on page
9*
•Front miscellaneous blanks kit spare parts on
page 9
•Rear miscellaneous blanks kit spare parts on
page 9
Table Continued
Illustrated parts catalog 7

Item Description
•Rear 2 SFF/miscellaneous blanks and bracket
kit spare parts on page 10
•Fan blank, Smart Storage Battery latch, and
PCIe retainer kit spare parts on page 10
•Optical drive blank spare part on page 10
* Not shown
For more information, see Removal and replacement procedures on page 35.
Air baffle spare part
Customer self repair on page 25: mandatory
Description Spare part number
Air baffle 875054-001
Access panel spare parts
Customer self repair on page 25: mandatory
Description Spare part number
Access panel (SFF model) 875052-001
Access panel (LFF model) 875053-001
Tertiary PCI riser cage spare part
Customer self repair on page 25: optional
Description Spare part number
Tertiary PCI riser cage 875057-001
Primary and secondary PCI riser cage spare part
Customer self repair on page 25: mandatory
Description Spare part number
Primary and secondary PCI riser cage 875056-001
Chassis ears spare parts
Customer self repair on page 25: mandatory
8 Air baffle spare part

Description Spare part number
SFF standard left and right chassis ears kit 875083-001
LFF power/UID left and right chassis ears kit 875084-001
Fan cage spare part
Customer self repair on page 25: mandatory
Description Spare part number
Fan cage 875055-001
2U bezel spare part
Customer self repair on page 25: mandatory
Description Spare part number
2U bezel 875065-001
Rail kit spare parts
Customer self repair on page 25: mandatory
Description Spare part number
SFF 2U easy install rail kit 744114-001
LFF 2U easy install rail kit 744115-001
2U cable management arm 744116-001
Miscellaneous blanks kits spare parts
Front miscellaneous blanks kit spare parts
Customer self repair on page 25: mandatory
Description Spare part number
Front miscellaneous blanks kit 875069-001
2 SFF Flex Bay hard drive blank —
Hard drive box, standard blank —
Hard drive box blank, NVMe —
LFF hard drive box blank —
Rear miscellaneous blanks kit spare parts
Customer self repair on page 25: mandatory
Fan cage spare part 9

Description Spare part number
Rear miscellaneous blanks kit 875067-001
4 LFF backplane bracket (3) —
Rear 2 SFF serial blank —
Secondary PCI blank —
PCI riser cage blank for optional board —
PCI riser cage blank for optional board, with screw —
Optional PCI serial blank —
Rear 2 SFF/miscellaneous blanks and bracket kit spare parts
Customer self repair on page 25: mandatory
Description Spare part number
Rear 2 SFF/miscellaneous blanks and bracket kit 875068-001
Rear 2 SFF 2U bracket —
Rear 2 SFF module blank assembly —
Tertiary riser blank assembly —
Fan blank, Smart Storage Battery latch, and PCIe retainer kit spare parts
Customer self repair on page 25: mandatory
Description Spare part number
Fan blank, Smart Storage Battery latch, and PCIe
retainer kit
875066-001
Smart Storage Battery latch —
PCIe GPU retainer assembly —
Tertiary PCI riser cage retainer assembly —
Fan blank (2) —
Optical drive blank spare part
Customer self repair on page 25: mandatory
Description Spare part number
Optical drive blank 707300-001
System components
Hewlett Packard Enterprise continually improves and changes product parts. For complete and current
supported parts information, see the Hewlett Packard Enterprise PartSurfer website.
10 Rear 2 SFF/miscellaneous blanks and bracket kit spare parts

Item Description
1DIMM spare parts on page 12
2Processor spare parts on page 12
•31XX processor spare parts on page 12
•41XX processor spare parts on page 12
•51XX processor spare parts on page 12
•61xx processor spare parts on page 13
•81xx processor spare parts on page 13
3Heatsink spare parts on page 14
4Power supply spare parts on page 14
5Controller spare parts on page 14
•Smart Array controller spare parts on page
14
•Host bus adapter spare parts on page 15
•Converged network adapter spare parts on
page 15
6PCI riser board spare parts on page 15
7FlexibleLOM adapter spare parts on page 16
8System board spare part on page 16
9System battery spare part on page 16*
Illustrated parts catalog 11

* Not shown
For more information, see Removal and replacement procedures on page 35.
DIMM spare parts
Customer self repair on page 25: mandatory
Description Spare part number
DIMM, 8GB PC4-2666V-R,1Gx8 850879-001
DIMM, 16GB PC4-2666V-R,2Rx4 850880-001
DIMM, 16GB PC4-2666V-R,1Rx8 868846-001
DIMM, 32GB PC4-2666V-R,2Gx4 850881-001
DIMM, 64GB PC4-2666V-L,2Gx4 850882-001
Processor spare parts
31XX processor spare parts
Customer self repair on page 25: no
Description Spare part number
1.75-GHz Intel Xeon-B 3104 processor 875709-001
1.75-GHz Intel Xeon-B 3106 processor 875710-001
41XX processor spare parts
Customer self repair on page 25: no
Description Spare part number
1.8-GHz Intel Xeon-S 4108 processor 875712-001
2.1-GHz Intel Xeon-S 4110 processor 875711-001
2.6-GHz Intel Xeon-S 4112 processor 875714-001
2.2-GHz Intel Xeon-S 4114 processor 875713-001
2.1-GHz Intel Xeon-S 4116 processor 875716-001
51XX processor spare parts
Customer self repair on page 25: no
Description Spare part number
2.4-GHz Intel Xeon-G 5115 processor 878082-001
2.3-GHz Intel Xeon-G 5118 processor 875717-001
2.2-GHz Intel Xeon-G 5120 processor 875718-001
3.6-GHz Intel Xeon-G 5122 processor 875719-001
12 DIMM spare parts

61xx processor spare parts
Customer self repair on page 25: no
Description Spare part number
2.6-GHz Intel Xeon-G 6126 processor 875720-001
3.4-GHz Intel Xeon-G 6128 processor 875721-001
2.1-GHz Intel Xeon-G 6130 processor 874736-001
2.6-GHz Intel Xeon-G 6132 processor 875722-001
3.2-GHz Intel Xeon-G 6134 processor 875723-001
3.2-GHz Intel Xeon-G 6134M processor 878083-001
3.0-GHz Intel Xeon-G 6136 processor 875724-001
2.0-GHz Intel Xeon-G 6138 processor 874735-001
2.3-GHz Intel Xeon-G 6140 processor 874734-001
2.3-GHz Intel Xeon-G 6140M processor 878084-001
2.6-GHz Intel Xeon-G 6142 processor 874733-001
2.6-GHz Intel Xeon-G 6142M processor 878085-001
2.4-GHz Intel Xeon-G 6148 processor 874732-001
2.7-GHz Intel Xeon-G 6150 processor 874731-001
2.1-GHz Intel Xeon-G 6152 processor 874730-001
3.0-GHz Intel Xeon-G 6154 processor 875727-001
81xx processor spare parts
Customer self repair on page 25: no
Description Spare part number
2.0-GHz Intel Xeon-G 8153 processor 875728-001
3.6-GHz Intel Xeon-G 8156 processor 875732-001
3.0-GHz Intel Xeon-G 8158 processor 875733-001
2.1-GHz Intel Xeon-G 8160 processor 874729-001
2.1-GHz Intel Xeon-G 8160M processor 878086-001
2.0-GHz Intel Xeon-G 8164 processor 875729-001
2.7-GHz Intel Xeon-G 8168 processor 875730-001
2.7-GHz Intel Xeon-G 8168 processor 875730-001
2.1-GHz Intel Xeon-G 8170 processor 874728-001
2.1-GHz Intel Xeon-G 8170M processor 878087-001
2.1-GHz Intel Xeon-G 8176 processor 874727-001
Table Continued
61xx processor spare parts 13

Description Spare part number
2.1-GHz Intel Xeon-G 8176 processor 874727-001
2.1-GHz Intel Xeon-G 8176M processor 878088-001
2.5-GHz Intel Xeon-G 8180 processor 875731-001
2.5-GHz Intel Xeon-G 8180 processor 878089-001
Heatsink spare parts
Customer self repair on page 25: no
Description Spare part number
Standard heatsink 875070-001
High-performance heatsink 875071-001
1U 4 LFF midplane cage heatsink 872452-001
Power supply spare parts
Customer self repair on page 25: mandatory
Description Spare part number
800 W, Flex Slot DC 277V 866727-001
800 W, Flex Slot 480VDC 866728-001
500 W, Flex Slot Platinum 866729-001
800 W, Flex Slot Platinum 866730-001
800 W, Flex Slot HE-T 866793-001
1600 W, Flex Slot Platinum 863373-001
Controller spare parts
Smart Array controller spare parts
Customer self repair on page 25: mandatory
Description Spare part number
HPE Smart Array E208i-a Controller 836259-001
HPE Smart Array P408i-a Controller 836260-001
HPE Smart Array P816i-a Controller 836261-001
HPE Smart Array E208i-p Controller 836266-001
HPE Smart Array E208e-p Controller 836267-001
HPE Smart Array P408i-p Controller 836269-001
HPE Smart Array P408e-p Controller 836270-001
14 Heatsink spare parts

Host bus adapter spare parts
Customer self repair on page 25: mandatory
Description Spare part
number
HPE SN1600Q 32Gb 1p FC HBA 868140-001
HPE SN1600Q 32Gb 2p FC HBA 868141-001
HPE SN1600E 32Gb 2p FC HBA 869999-001
HPE 81Q PCI-e FC HBA 489190-001
HPE SN1200E 16Gb 1p FC HBA 870001-001
HPE SN1200E 16Gb 2p FC HBA 870002-001
HPE 82Q 8Gb Dual Port PCI-e FC HBA 489191-001
HPE StoreFabric SN1100E 4p 16Gb FC HBA 853008-001
HPE StoreFabric 84E 4-port 8Gb FC HBA 780686-001
HPE 81E 8Gb SP PCI-e FC HBA 697889-001
HPE 82E 8Gb Dual-port PCI-e FC HBA 697890-001
HPE StoreFabric 84Q 4p 8Gb FC HBA 853009-001
HPE SN1100Q 16Gb 1p FC HBA 863010-001
HPE SN1100Q 16Gb 2p FC HBA 853011-001
Converged network adapter spare parts
Customer self repair on page 25: mandatory
Description Spare part number
HPE CN1100R 2P Converged Network Adapter 706801-001
HPE StoreFabric CN1100R-T 10Gb Converged
Network Adapter
872605-001
HPE StoreFabric CN1200E 10Gb Converged
Network Adapter
767078-001
HPE StoreFabric CN1200E-T 10Gb Converged
Network Adapter
827607-001
PCI riser board spare parts
Customer self repair on page 25: optional
Description Spare part number
2x8 x16 PCIe M.2 riser 877946-001
2x8 x16 PCIe riser 875058-001
x16 x16 PCIe S1/2 riser 875059-001
Table Continued
Host bus adapter spare parts 15

Description Spare part number
x16 x16 PCIe S2/3 riser 875060-001
x16 PCIe tertiary riser 875061-001
2 Slim SAS tertiary riser 875062-001
1-S x16 1U riser 875085-001
3 x8/x1 Slim SAS riser 875086-001
Quad Slim SAS riser 875087-001
FlexibleLOM adapter spare parts
Customer self repair on page 25: mandatory
Description Spare part number
HPE InfiniBand FDR/EN 40Gb 2-port, 544+ FLR-
QSFP Adapter
764737-001
HPE InfiniBand FDR/EN 40Gb 2-port, 544+ QSFP
Adapter
764736-001
System board spare part
Customer self repair on page 25: optional
Description Spare part number
System board (DL380) 875073-001
System board (DL388) 875074-001
System battery spare part
Customer self repair on page 25: mandatory
Description Spare part number
System battery 319603-001
Server options
Hewlett Packard Enterprise continually improves and changes product parts. For complete and current
supported parts information, see the Hewlett Packard Enterprise PartSurfer website.
16 FlexibleLOM adapter spare parts

Item Description
1Drive spare parts on page 18
•Hot-plug drive spare parts on page 18
•Solid state NVMe spare parts on page 19
•Solid state drive uFF M.2 spare parts on page
20
•Solid state drive SAS spare parts on page 20
•Solid state drive SATA spare parts on page
20
2Fan spare parts on page 21
3Backplane board spare parts on page 22
4Chassis Intrusion Detection Switch spare part on
page 22
5Rear serial port interface spare part on page 22
6GPU options spare parts on page 22
7HPE 12Gb DL380 Gen10 SAS Expander Card
spare part on page 23
8HPE Smart Storage Battery spare parts on page
23
9Power module spare parts on page 23
10 LFF I/O UID spare parts on page 23*
Table Continued
Illustrated parts catalog 17

Item Description
11 HPE Trusted Platform Module 2.0 spare part on
page 23*
12 Cable spare parts on page 23*
13 Thermal grease spare parts on page 24*
* Not shown
For more information, see Removal and replacement procedures on page 35.
Drive spare parts
Hot-plug drive spare parts
Customer self repair on page 25: mandatory
Description Spare part
number
1TB SAS 7.2K SFF SC DS HDD 832984-001
1TB SAS 7.2K SFF SC 512e DS HDD 765872-001
1TB SATA 7.2K LFF SC DS HDD 862128-001
1TB SAS 7.2K LFF SC DS HDD 846612-001
1TB SATA 7.2K SFF SC 512e DS HDD 765868-001
1TB SATA 7.2K SFF SC DS HDD 656108-001
2TB SAS 7.2K SFF SC 512e DS HDD 765873-001
2TB SAS 12G 7.2K LFF SC DS HDD 872744-001
2TB SAS 7.2K LFF SC HDD 819078-001
2TB SATA 7.2K 6G LFF SC DS HDD 872771-001
2TB SATA 7.2K LFF SC HDD 862126-001
2TB SATA 7.2K SFF SC 512e DS HDD 765869-001
3TB SATA 7.2K LFF SC DS HDD 862129-001
3TB SAS 7.2K LFF SC DS HDD 846614-001
4TB SAS 7.2K LFF SC 512e DS HDD 862141-001
4TB SAS 12G 7.2K LFF SC DS HDD 872745-001
4TB SAS 7.2K LFF SC HDD 819079-001
4TB SATA 7.2K 6G LFF SC DS HDD 872772-001
4TB SATA 7.2K LFF SC HDD 862127-001
4TB SATA 7.2K LFF SC 512e DS HDD 862139-001
6TB SATA 7.2K LFF SC DS HDD 846608-001
6TB SATA 7.2K LFF SC 512e DS HDD 862138-001
Table Continued
18 Drive spare parts

Description Spare part
number
6TB SAS 7.2K LFF SC 512e DS HDD 862140-001
8TB SATA 7.2K LFF SC He 512e DS HDD 861609-001
8TB SATA 7.2K LFF SC 512e DS HDD 820033-001
10TB SATA 7.2K LFF SC He 512e DS HDD 857967-001
6TB SAS 7.2K LFF SC DS HDD 846610-001
8TB SAS 7.2K LFF SC He 512e DS HDD 861607-001
8TB SAS 7.2K LFF SC 512e DS HDD 820032-001
10TB SAS 7.2K LFF SC He 512e DS HDD 857965-001
300GB SAS 10k SFF SC HDD 785410-001
300GB SAS 10K SFF SC DS HDD 872735-001
600GB SAS 10K SFF SC DS HDD 872736-001
600GB SAS 10K SFF SC HDD 781577-001
900GB SAS 10K SFF SC HDD 785411-001
1.2TB SAS 10K SFF SC HDD 781578-001
1.2TB SAS 10K SFF SC DS HDD 872737-001
1.8TB SAS 10K SFF SC 512e DS HDD 872738-001
1.8TB SAS 10K SFF SC 512e HDD 791055-001
300GB SAS 15K SFF SC HDD 759546-001
300GB SAS 15K SFF SC DS HDD 870792-001
450GB SAS 15K SFF SC HDD 759547-001
600GB SAS 15K SFF SC DS HDD 870794-001
600GB SAS 15K SFF SC 512e DS HDD 870797-001
600GB SAS 15K SFF SC HDD 759548-001
600GB SAS 15K SFF SC 512e HDD 748435-001
900GB SAS 15K SFF SC DS HDD 870795-001
900GB SAS 15K SFF SC 512e DS HDD 870798-001
Solid state NVMe spare parts
Customer self repair on page 25: mandatory
Description Spare part
number
400GB NVMe x4 WI SFF SC SSD 765059-001
400GB NVMe x4 RI SFF SCN SSD 765067-001
400GB NVMe x4 MU SFF SCN SSD 765063-001
Table Continued
Solid state NVMe spare parts 19

Description Spare part
number
800GB NVMe x4 WI SFF SCN SSD 765060-001
800GB NVMe x4 MU SFF SCN SSD 765064-001
1.2TB NVMe x4 RI SFF SCN SSD 765068-001
1.6TB NVMe x4 WI SFF SCN SSD 765061-001
1.6TB NVMe x4 MU SFF SCN SSD 765065-001
2TB NVMe x4 MU SFF SCN SSD 765066-001
2TB NVMe x4 RI SFF SCN SSD 765069-001
2TB NVMe x4 WI SFF SCN SSD 765062-001
Solid state drive uFF M.2 spare parts
Customer self repair on page 25: mandatory
Description Spare part
number
120GB SATA RI uFF Dual M.2 Kit 831995-001
120GB SATA RI uFF M.2 Kit 781565-001
340GB SATA RI uFF Dual M.2 Kit 781566-001
340GB SATA RI uFF M.2 Kit 781566-001
Solid state drive SAS spare parts
Customer self repair on page 25: mandatory
Description Spare part
number
400GB SAS MU SFF SC SSD 822784-001
480GB SAS RI SFF SC SSD 817047-001
800GB SAS MU SFF SC SSD 822786-001
960GB SAS RI SFF SC SSD 817049-001
1.6TB SAS MU SFF SC SSD 822788-001
1.92TB SAS RI SFF SC SSD 817051-001
3.2TB SAS MU SFF SC SSD 822790-001
3.84TB SAS RI SFF SC SSD 817053-001
Solid state drive SATA spare parts
Customer self repair on page 25: mandatory
20 Solid state drive uFF M.2 spare parts
Table of contents
Other HP Enterprise Server manuals
Popular Server manuals by other brands

Meyer Sound
Meyer Sound Galileo GALAXY 408 user guide

Mitsubishi Electric
Mitsubishi Electric DX-VS1UE Setup guide

Dell
Dell PowerEdge T710 Hardware installation instructions

Dell
Dell 5WC10 Installation and service manual

Vivotek
Vivotek VS2101 Quick installation guide

Supermicro
Supermicro SUPERSERVER 6028TP-HC1R user manual

Dell
Dell E01B002 owner's manual

Sun Oracle
Sun Oracle Sun Server X4-2 Service manual

SONNETEER
SONNETEER Morpheus quick start guide

Lucent Technologies
Lucent Technologies Stinger MRT 19 Getting started guide

Gigabyte
Gigabyte G292-Z45 manual

Atlantis Land
Atlantis Land NetServer Pro A02-PSU-W54 quick start guide