manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HPM
  6. •
  7. Accessories
  8. •
  9. HPM XLP912WEWE User manual

HPM XLP912WEWE User manual

1Load Compatibility
XLP912WEWE and XLP913WEWE are Passive Infra-Red (PIR) movement sensors. When movement is
detected, the connected load will switch on for a time period that can be preset by the user.
XLP912WEWE is a 3-wire product and thus requires a neutral. It has a relay output which turns the load on
and off without dimming.
XLP913WEWE is a 2-wire product with a solid state output which turns the load on and off gradually over a few
seconds.
Both models have adjustments for the following:
1 Time delay (1 second to 16 minutes)
The period of time the load stays on after movement is detected.
2 Detection range (3 metres to 10 metres)
See range diagrams overleaf.
3 Brightness threshhold (3 lux to 1000 lux)
Sensor will only operate if ambient light is below this value. For day time operation use a higher lux setting,
and for night operation only use a lower lux setting.
These adjustments are located underneath the front cover.
Note: Minimum load for XLP913WEWE is 40W.
Load Type
Maximum Load
XLP912WEWE XLP913WEWE
Incandescent 1000W 400W
240V Halogen 1000W 400W
Low Voltage Halogen
with electronic
transformer
500VA 400VA
Low Voltage Halogen
with ferromagnetic
transformer
500VA 400VA
Linear Fluorescent 500VA Not Suitable
Compact Fluorescent 500VA Not Suitable
Fan Motor 100VA Not Suitable
Contactor 1 max (< 2A) Not Suitable
10 m
3 m
16 °
1°
3 lux1000 lux
Excel Movement Sensor
Cat XLP912WEWE & XLP913WEWE
Instruction Manual
2Operation
Note: Connecting XLP913WEWE sensors in parallel is only possible with an incandescent load. The minimum
load must be 40W multiplied by the number of sensors (e.g. 120W for 3 sensors).
Wiring several sensors in parallel (no neutral is required for
XLP913WEWE)
Wiring a single sensor (no neutral required for XLP913WEWE)
N
L
L N$
Field of view with detection range set to 10 metres:
Field of view with detection range set to 3 metres:
4 m
5 m
10 m
1,5 m
0,5 m
1,3 m
1,5 m
3 m
1,2 m
1,5 m
3 m
1,2 m
5 m
10 m
4 m
5 m
10 m
1,5 m
0,5 m
1,3 m
1,5 m
3 m
1,2 m
1,5 m
3 m
1,2 m
5 m
10 m
4 m
5 m
10 m
1,5 m
0,5 m
1,3 m
1,5 m
3 m
1,2 m
1,5 m
3 m
1,2 m
5 m
10 m
4 m
5 m
10 m
1,5 m
0,5 m
1,3 m
1,5 m
3 m
1,2 m
1,5 m
3 m
1,2 m
5 m
10 m
2
3
4
Operation continued
Wiring
Mechanism Dimensions
Horizontal
Horizontal
Vertical
Vertical
Customer Service
For all customer service and technical support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpm.com.au
HPM Legrand - New Zealand
0800 476 009
www.hpm.co.nz
Legrand Australia Pty Ltd
ABN: 31 000 102 661
Warranty
HPM Cat XLP912WEWE & XLP913WEWE are warranted
as here and after appears, against faulty material and/
or workmanship for a period of one year from the day of
purchase. The obligation of the manufacturer under this
warranty is limited to servicing and replacing defective
parts when the unit is returned to the authorised place
of purchase. To obtain warranty repair, the purchase
receipt should be returned with the product. This warranty
becomes void on any unit which has been tampered with
or damaged by accident, short circuited, loaded beyond
rating or damaged otherwise by improper operation. The
warranty is also conditional on the unit being installed
by a licensed electrical contractor. All other warranties,
whether expressed or implied, and whether arising by
operation of law or otherwise are hereby excluded.
23956A
The 2-wire XLP913WEWE dims the load up and
down over a few seconds when switching on and
off. It does this in either leading or trailing edge
mode, depending on the type of load connected.
The unit can be set to automatically detect the load
type, or manually set to either leading or trailing
edge.
Automatic load detection (factory default setting)
The unit will detect the load and automatically
select leading or trailing edge. Press and hold
middle and right buttons for 10 seconds.
Trailing edge mode
Use for incandescent or electronic transformer loads.
Press and hold left and middle buttons for 10 seconds.
Cat No XLP912WEWE XLP913WEWE
Supply voltage 230-240V a.c. 230-240V a.c.
2 or 3 wire 3 wire 2 wire
Minimum load 0W 40W
Maximum load See Load Compatibility
Terminal capacity 2 x 1.5mm² or 1 x 2.5mm²
IP rating IP41
Storage
temperature
0°C to +35°C
Operating
temperature
0°C to +35°C
Resistant to the
following agents
Hexane, methylated spirits, soapy
water, diluted ammonia, diluted
pure bleach (10%), glass cleaning
substance, pre-impregnated wipes
Not resistant
to the following
agents
Acetone, tar remover,
trichloroethylene
Leading edge mode
Use for incandescent or ferromagnetic transformer
loads. Press and hold left and right buttons for 10
seconds.
5 Dimming Mode (XLP913WEWE Only)
Warning: These products must only be connected to
the mains supply by a qualied electrician.
Technical Characteristics

This manual suits for next models

1

Other HPM Accessories manuals

HPM D641/B User manual

HPM

HPM D641/B User manual

HPM 630R02WE User manual

HPM

HPM 630R02WE User manual

HPM D641/PILR User manual

HPM

HPM D641/PILR User manual

HPM D641/BFL User manual

HPM

HPM D641/BFL User manual

HPM 630S02WE User manual

HPM

HPM 630S02WE User manual

HPM 630/3 User manual

HPM

HPM 630/3 User manual

Popular Accessories manuals by other brands

AmazonBasics B00LRK8HJ8 instruction manual

AmazonBasics

AmazonBasics B00LRK8HJ8 instruction manual

Leviton T6525 manual

Leviton

Leviton T6525 manual

Baumer 10158758 manual

Baumer

Baumer 10158758 manual

Milesight EM300 Series user guide

Milesight

Milesight EM300 Series user guide

myfox TA 4004 user guide

myfox

myfox TA 4004 user guide

EMX Industries IRB-MON instruction manual

EMX Industries

EMX Industries IRB-MON instruction manual

Salewa 1174 Ultra Train 18 BP 5740 manual

Salewa

Salewa 1174 Ultra Train 18 BP 5740 manual

AEG MD 5613 instruction manual

AEG

AEG MD 5613 instruction manual

HBM PW15PH Series Mounting instructions

HBM

HBM PW15PH Series Mounting instructions

Soehnle BARI user manual

Soehnle

Soehnle BARI user manual

System Sensor 52051E-RF Installation and maintenance instructions

System Sensor

System Sensor 52051E-RF Installation and maintenance instructions

madebyzen Nomad manual

madebyzen

madebyzen Nomad manual

Datalogic S51-PA Series instruction manual

Datalogic

Datalogic S51-PA Series instruction manual

Teledyne Lecroy PP019 user manual

Teledyne Lecroy

Teledyne Lecroy PP019 user manual

Philips SPF1002 Specifications

Philips

Philips SPF1002 Specifications

Oldham c1100 user manual

Oldham

Oldham c1100 user manual

System Sensor 22051E Installation and maintenance instructions

System Sensor

System Sensor 22051E Installation and maintenance instructions

Emerson Rosemount 402 quick start guide

Emerson

Emerson Rosemount 402 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.