HTL HTL-Advansys-15.2U Installation and maintenance instructions

2020
The passport meets the requirements of GOST 2.601
HTL-ADVANSYS LLC
OKPD2 (Russian Product Classification Code) 28.25.14.110
EAC
Bactericidal Air Recirculator-Irradiator. Closed/opened type.
«HTL-Advansys-15.2U»
Technical Passport
(Operators Manual)
28.25.14−001−89695785−2020 PS

28.25.14−001−89695785−2020 PS
2 из 12
1General
1.1 The “HTL-Advansys-15.2U” bactericidal air recirculator-irradiator of closed/opened type
(hereinafter referred to as the Recirculator) is manufactured by "HTL-Advansys" LLC
according to Spec. 28.25.14-001-89695785-2020.
1.2 Application.
1.2.1 The Recirculator is designed for air disinfection in the presence of humans.
It is used in residential, office, warehouse, shopping and entertainment areas, educational,
exhibition and medical institutions.
1.2.2 Any other usage of the Recirculator must be approved by the manufacturer. Any misuse of
the Recirculator may lead to its failure or may cause damage to a person (user) health. The warranty
becomes invalid in this case!
1.3 Some design and configuration changes may not be included in the Passport as the
improvements of operational and technical parameters of the Recirculator are carried out constantly.
2Operational and technical specifications
2.1 The main specifications of the Recirculator are shown in the Table 1.
Table 1 - Basic technical data
Parameter
Value
HTL-Advansys-15.2U
HTL-Advansys-15.2U
with a stand
Capacity , m3per hour
70
Total power, W
45
Power supply Voltage, V
230±10%
Power supply Frequency, Hz
50
Disinfection efficiency, %, not less than
99
IP protection according to GOST 14254-2015
IP20
Wavelength, nm
253,7
UV radiation source
2x15W Ozone free Germicidal lamp
PHILIPS/OSRAM/Ledvance
Lamp bactericidal flow, F. Bq. W, not less than
9.2
Air Filter
6*G1
Installation
wall-mounted / floor based
Warm-up time, sec, not longer than
1
Dimensions (H×L×B), mm
600×260×110
700×260×200
Weight, kg
4.5
6.4
Noise level, dBA, not higher than
30
2.2 Reliability Indicators
2.2.1 The UV lamp life time while operated and maintained properly is not less than 9000
operation hours.
2.2.2 The warranty does not cover the UV lamp.
2.3 The Recirculator Operation Conditions are shown in the Table 2

28.25.14−001−89695785−2020 PS
3 из 12
Table 2 - Recirculator Operation Conditions
Parameter
Value
Type of climatic design as per GOST 15150-69
UHL4.2 (moderate
or cold climate)
Allowable ambient temperature , ºС
+5…+35
Relative air humidity at t = 25 ° C,%, no more
80
Atmospheric pressure, kPa
84…107
Type of atmosphere according to the content of corrosive agents as per GOST
15150-69
II
3The Recirculator Set
3.1 The Delivery set is shown in The Table 3
Table 3 - Delivery set
№
Description
Quantity, pcs
1
«Advansys-15.2U» Bactericidal Air Recirculator-Irradiator.
Closed/opened type
1
2
Operation Manual (Technical Passport)
1
3
Power cord
1
4
Hangers (Brackets)
2
5
Safety glasses
1
3.2 The delivery set may include an extra components and documents if so stipulated in the
Contract.
4The principle of operation
The recirculator structurally consists of: germicidal lamps placed on the front wall of the mounting
panel. With the help of a fan, air flows through light-shielding louvers and filtering elements of class
G1 into the reactor chamber, where it is disinfected by receiving the necessary dose of UV radiation
when moving along the bactericidal lamp.
6Pre-start procedure
1. Remove the Recirculator from the shipping container. Let it stay at room temperature for 2-3
hours before switching it ON if the Recirculator has been transported at sub-zero
temperatures.
2. Install the Recirculator on an open surface or fix it vertically on the wall (after removing the
stand) by fixing hangers (brackets) so that the lowest part of the device is at least 0.7 m
above the floor. The hangers are to be pre-screwed to the body with two screws.
3. The recirculator must be placed in the room so that air intake and discharge are unimpeded.
4. Plug the power cord into a 230V socket. Turn on the "Network" switch. Check the operation
of the lamps by the indicator (the HTL-ADVANSYS inscription will light up in blue).
5. The room surfaces should be treated in accordance with SanPiN 2.1.3.2630-10 before
starting the treatment of room air using the recirculator.
6. The germicidal lamps operating time is recorded in “The Germicidal lamps operation time
Log”. If the device has an operating hour meter, the operating time is monitored visually.

28.25.14−001−89695785−2020 PS
4 из 12
7Safety instructions
1. The UV lamps have a special glass with high transmittance of the bactericidal UV rays
and simultaneous absorption of radiation below 200 nm which is forming ozone in the air. As a result,
the ozone formation is insignificant (within the MPC). It disappears completely in 30-50 hours of the
UV lamp operation.
2. In case of integrity violation of the germicidal lamps bulb, the thorough demercurization
of the room where it occurs must be carried out following the "Methodological recommendations for
monitoring of the current and final demercurizations and evaluating their effectiveness" (no. 4545-87
of 31.12.1987).
3. The expired and faulty germicidal lamps are to be packed and stocked in a separate
room. The disposal of the germicidal lamps must be carried out in accordance with the provisions of
«The operation instructions for outdoor lighting units in cities, towns and rural localities» (No. 120 of
12.05.88).
8Safety Regulations
1. Except the instructions stipulated in this passport, you must follow the General safety
and accident prevention rules.
WARNING
It is forbidden to ignore the safety measures provided in this section.
2. The Manufacturer guarantees the Recirculator safety in accordance with the
requirements of Spec. 28.25.14-001-89695785-2020 and TR CU 020/2011 The Customs Union
Technical regulations for "Electromagnetic compatibility of technical facilities" "Low-voltage
equipment safety".
3. The Recirculator is not intended for use by persons with disabilities, reduced physical,
sensory or mental capabilities, or persons with insufficient experience and knowledge except under
supervision and guidance of persons responsible for their safety.
WARNING
It is forbidden to use the Recirculator without having studied this passport.
WARNING
It is forbidden to make any design changes without the manufacturer's permission. It is
forbidden to install the devices on the Recirculator not provided by the manufacturer.
It is Forbidden:
-to use the Recirculator for other purposes which it is not intended for.
WARNING
The recirculator design is electrically safe. However, the recirculator is an
electrical device and it is subject to all safety requirements for the operation
of electrical equipment powered by AC 230 V, 50 Hz
-If The Recirculator does not comply with this passport and the technical specification the
installation is forbidden.
-Loading and unloading of the Recirculator must be executed in accordance with GOST
12.3.009-76 smoothly without jerking and striking. Dropping from vehicles is not permitted.

28.25.14−001−89695785−2020 PS
5 из 12
9Operating procedure
The Recirculator operating time should be recorded in the Readings and Monitoring Log. Results of
visual observations of the germicidal lamp surface cleanliness should be recorded periodically to
determine the optimal period for the Recirculator preventive maintenance.
Operation of the device in the closed-type air recirculator-irradiator mode:
1) Place the recirculator on a hard surface using a stand in an open space of at least 1 m²;
2) If it is necessary to install on a wall, it is necessary to dismantle the stand by first unscrewing the
bolts of the stand clamps;
3) Screw the hangers (brackets) supplied with the recirculator into the holes to fix them.
4) Connect the cable to the power connector;
5) Turn on the power button of the recirculator.
Operation of the device in the open-type air recirculator-irradiator mode:
1) Turn off the Recirculator with the power button 1;
2) Install the device with its face towards the surfaces to be irradiated;
3) Open the reactor chamber door;
4) Step out of direct exposure to UV radiation (behind the unit) as shown in figure 1;
5) Put the safety glasses on;
6) Turn on the device in the irradiation mode by pressing the power button 1;
7) Leave the room for the entire period of the irradiator operation. The recommended operating
time of the Recirculator in open mode is 15-90 minutes for a 20 m² room.
Figure 1
WARNING
In any case Do not look at the emitters in order to avoid the eye cornea damage!
9. Maintenance
The maintenance of the Recirculator should be carried out by the Manufacturer or by a certified
service facility only.
WARNING
DIY troubleshooting, repair and adjustment are not allowed.

28.25.14−001−89695785−2020 PS
6 из 12
Troubleshooting
Table 5 - Troubleshooting
Problem
Possible Cause
Corrective Action
The Power indicator is not lit
The fuse is faulty
Replace the fuse
The UV indicators are blue (the
UV lamps are on), the fan is not
working
The fan failed
Replace the fan
The fan is working, the UV lamp
indicator(s) is(are) not lit
There is no contact between the
UV lamp and the lamp holder
Reinstall the UV lamp in the
holder
The UV lamp inoperative
Replace the UV lamp
The ECG (electronic ballast) is
faulty
Replace the ECG (electronic
ballast)
10 Shipping and storage
1. The Recirculator is shipped by all types of transport in accordance with the rules applicable to this
transport.
2. The Recirculator keeps workability under the vibration loads with a frequency of up to 20 Hz at 0.5
g acceleration.
3. The Recirculator is shipped in individual or multipack containers. The shipping container must have
an inscription: "Watch the glass."
4. The minimum and maximum permissible ambient temperature and humidity for transportation and
storage would be specified additionally in the shipping documents if necessary.
5. Climatic terms for the Recirculator transportation must correspond to the storage conditions 3 (G3)
as per GOST 15150-69 at temperatures from -40 ° C to + 60 ° C, relative humidity of 80% at + 25
°C.
6. The height of the storage pile should not exceed 2.7 m during transportation.
7. Container with the Recirculator must be stored indoors at temperatures
from -40 ° C to + 60 ° C, relative humidity of 90% at + 25 °C. A storage room must be protected
from precipitations, direct sunlight and aggressive environments.
8. The height of the storage pile should not exceed 1.7 m at the Recirculator boxes stowing. Boxes
with the Recirculator should be placed on pallets, racks or decking at 0.12 m from the floor and
external walls as minimum.
It is forbidden to place other types of cargo on the Recirculator cardboard box.
9. In order to avoid the mechanical damaging, follow the loading/unloading precautions.
Loading and unloading of the equipment must be executed according to the GOST 12.3.009-76
smoothly without jerking and striking. Dropping from vehicles is not permitted.
10. Packaged Recirculators must be stored on pallets at least 1 m away from the heating devices.
11 Manufacture’s warranty
1. The manufacturer warrants The Recirculator quality in accordance with the SPEC. 28.25.14-001-
89695785-2020 while it proper operated, stored and transported.
2. Warranty period is 12 months from the date of manufacture.
It is allowed to set warranty periods in vendor contracts.
3. The Recirculator or the failed parts are repaired by the Manufacturer during the warranty period.
4. The Manufacturer’s (Supplier) warranty becomes not valid in the case of:
-non-observance of operating rules by owners;
-lamp failure;
-careless storage and transportation;
-use of the Recirculator for other purposes which is not intended for;
-in the presence of mechanical damage to the recirculator caused by external factors;
-in case of malfunctions that have arisen as a result of exceeding the parameters specified in the
passport, as well as a result of a mismatch between the parameters of the electrical network and the
rated voltage;

28.25.14−001−89695785−2020 PS
7 из 12
-attempts of DIY repair during the warranty period.
5. This warranty does not infringe any Consumer legal rights granted by the applicable law.
6. Complaints.
The customer submits a complaint letter (if any) regarding the quality of the Recirculator to the
manufacturer. In the complaint the customer has to list the shortcomings: technical failures, visible
defects, etc. The complaint must be accompanied by the documents confirming the shortcomings of
the Recirculator. The claim can be made within the warranty period.
All the complaints, their summary and the measures taken must be recorded in the table as
follows:
Date
Summary of the complaint
Measures taken
12 Disposal Procedure
1The Recirculator structure and materials do not harm the environment and human health during
its storage, transportation and operation in compliance with operational documentation and
safety rules.
2The Recirculator end-of-life disposal is associated with the process of decommissioning,
decontamination (if necessary), removing from active inventory and forwarding to disposal.
3Upon expiration of the assigned parameters (service life) of The Recirculator it is taken from
operation. The end-user decides to:
- repair The Recirculator;
- verify and establish some new assigned parameters (service life);
- recycle it.
Verification and establishment of the new assigned parameters (service life) is carried out
according to the consumer program and methodology or manufacturer’s recommendations.
4It is recommended to utilize The Recirculator as consumer waste to the recyclable materials
and resources. The Recirculator must be disposed in compliance with the requirements listed in
paragraph 13.5 of this Section.
5If consumer decides to utilize The Recirculator and its components, he must follow the
requirements of waste management and environmental protection in accordance with:
- Russian Federal Law "Waste generated by production and consumption";
- Russian Federal Law " Environmental Protection Act ";
- health regulations and standards currently in force in the Russian Federation;
- national and international standards for resource conservation;
- other Federal laws and laws and regulations of the Russian Federation adopted in accordance
with them, Laws and other normative legal acts of the constituent entities of the Russian
Federation in force at the moment of liquidation (utilization).
6The Recirculator may be disposed according to the Rules of waste management and any other
document approved by the consumer. The approved consumer rules for waste disposal may not
violate the requirements listed in the paragraph 13.5 of this Section and may not be in contrary
with the Requirements of waste management and environmental protection established in the
Russian Federation.
7The Recirculator can be passed to a sole trader or authorized organization carrying out the
activities on collection, transportation, processing, utilization, neutralization and disposal of
waste. Utilization of The Recirculator may not violate the requirements listed in paragraph 13.5
of this Section.

28.25.14−001−89695785−2020 PS
8 из 12
8The Recirculator must be in a safe condition before disposal. The following organizational and
technical measures must be done:
- disconnect from the power supply;
- cleaning from pollutions, etc.
9At the sorting stage, identified and certified elements are preliminarily divided according to the
specified criteria into qualitatively different components in the form of recyclable materials (for
example, metals, plastics, etc.).
The body and other metal parts of The Recirculator are recyclable as secondary metal resources.

28.25.14−001−89695785−2020 PS
9 из 12
13 Acceptance Certificate
Bactericidal Air Recirculator. Closed/opened type
«HTL-Advansys-15U»
Serial number №
The Recirculator is manufactured in accordance with the Spec. 28.25.14-001-89695785-
2020, tested and verified for sell and operation.
Date of manufacture
Person
responsible for
the acceptance
(position)
(signature)
(surname)
(date)
Stamp here
Acc.to the
Agreement
Agreement №from « »202__
(if applicable)
(delivered on the base of designated document (name of the document))
If any additional information is required, please contact us:
Contacts
Manufacture
«HTL- Advansys», LLC
Manufacture address
Russia
Telephone
+371 28 300 003
+7 (929) 685-66-41
e-mail
HTL.Advansys.info@gmail.com
Web-site
HTL-Advansys.com

28.25.14−001−89695785−2020 PS
10 из 12
14 Certificate of Sale
1. To be filled in by the Seller
Bactericidal Air Recirculator. Closed/opened type
«HTL-Advansys-15U»
Serial number №
Date of sale (day, month, year)
Trade company (name, phone)
Name and signature of the Seller
Stamp here
15 Germicidal lamps operating time Log
1. Records of Germicidal lamps operating time are entered into the Table 6.
Table 6 - Records of Germicidal lamps operating time
Дата
Operation time (period of
operation)
Operating time
Position, initials, surname and
signature of the responsible
person
16 Records of failure during operation
1. Records of The Recirculator failure during the operation are entered into the Table 7.
Table 7 Records of The Recirculator failure during the operation
Date of
failure
The nature
(external
manifestation)
of the fault
Operation time
(period of
operation)
Adequate
corrective
actions
Position, initials,
surname and
signature of the
responsible person
Notices
17 Records of The Recirculator Operating Time before repair
1. Records of The Recirculator Operating time before the repair are entered into the Table 8
Note –User (consumer, operating company) is responsible for the implementation of safety rules
and operation manuals of The Recirculator. Repair of the failed Recirculator due to the user's fault
is performed at the expense of the user (consumer).
Table 8 Records of The Recirculator Operating time before repair
Date
Period of operation
Operating time
Name, position and
signature of the responsible
person

28.25.14−001−89695785−2020 PS
11 из 12
18 Service Records
1. The Recirculator Service Records are entered in the Table 9.
Table 9 - Service Records
Date
Comments on the technical
state
Designation of the
performed work
Position, initials,
surname and signature of
the responsible person
19 Repair Records
1. Information of the Recirculator repair woks are recorded into the Table 10.
Table 10 - Records of the Recirculator repairs.
Description
Reason
for the
repair
Date
Operating
time
before
repair,
days
Name of the
organization
performed the
repair
Position,
initials,
surname and
signature of
the
responsible
person
Start of the
repair
Completion
of the
repair
20 Special notices
The passport must not contain "writing" in pencil, dilutable ink, or erasures.
The wrong entry should be carefully crossed out and the new one should be written next to it. All
the new entries must be certified by the responsible person.
After the signature, the surname and initials of the responsible person must follow (it is allowed
to put the performer's personal stamp instead of the signature).
If there are not enough pages to fill in, you can add pages to the section. The additional pages are
numbered as follows: Х1-Х2
where Х1is the number (value) of the last page of the section which should be supplemented
with additional sheet to be filled in;
Х2- number (value) of the additional sheet in accordance with the order of the supplement (the
first additional sheet of the section is numbered "1").

28.25.14−001−89695785−2020 PS
12 из 12
Table of contents
Popular Air Cleaner manuals by other brands

Lennox
Lennox HEPA Bypass Air Filtration Systems HEPA-20 Brochure & specs

smartmi
smartmi KQJHQ01ZM user manual

Daikin
Daikin DV1-15-2117-AB Installation & operation manual

Medic Therapeutics
Medic Therapeutics Mini Air Purifier user manual

Plasma Ions
Plasma Ions PS-500T2 quick start guide

Trion
Trion Air Bear Series Installation & operation