General Information
This guide covers the installation of the SP2 POE Weatherproof Handset/Speaker Amplifier Station (see Figure 1). Refer to
Publication 42004-789 for detailed explanations of the available configuration options and adjustments, system design
information, and warranty information. GAI-Tronics’ product documentation is located on the GAI-Tronics website at
https://www.gai-tronics.com.
Options
•speaker amplifier only (no handset)
•PVC or Hytrel®handset cords in 6-, 15-, or 25-foot lengths
•headset with page pressbar
•All-Call push button
•five configurable alternate page
destinations with selector switch
•conformal PCBA coating
Settings and Adjustments
Optional equipment is factory installed and preconfigured to default settings. Complete the following settings and
adjustments after installation:
•speaker volume
•receiver volume
•series/parallel speaker connection
•station ID and zone selector
Figure 1. SP2 POE Weatherproof Handset/Speaker Amplifier Station

Pub. 42004-789BQG
SP2 POE Weatherproof Handset/Speaker Amplifier Station Quick Installation Guide Page 2 of 4
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-xxxxQG Quick Guides\42004-789BQG.docx
01/20
Installation
Important Safety Instructions
•Read, follow, and retain instructions—All safety and operating instructions should be read and followed before
operating the unit. Retain instructions for future reference.
•Heed warnings—Adhere to all warnings on the unit and in the operating instructions.
•Attachments—Attachments not recommended by the product manufacturer should not be used, as they may cause
hazards.
•Servicing—Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
ATTENTION
—Install equipment without modification and according to all applicable local, national, and
international electrical codes. North America—Consult the National Electrical Code (NFPA
70), Canadian Standards Association (CSA 22.1), and local codes for specific requirements
regarding your installation. Class 2 circuit wiring must be performed in accordance with the
NEC.
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with state and
national regulations, as well as safety practices for this type of equipment.
WARNING
—Do not disconnect equipment while energized.
Ensure proper grounding to protective earthing.
Enclosure Mounting
The mounting location must be flat and provide proper clearance, rigidity, and strength to support the enclosure and all
contained devices.
1. Mount the enclosure using the four 0.437-inch (11 mm) diameter holes located on the mounting flanges with 3/8-inch
(M8) hardware (see Figure 2).
•The suggested mounting height for all station enclosures is 48 inches (1219 mm) to the center of the bottom
mounting holes of the enclosure.
•SP2 stations are not supplied with conduit or cable openings.
2. Remove the front panel.
3. Drill or punch entry openings in the rear section of the enclosure (see Figure 2).
•The station is suitable for bottom and/or side entry.
•Bottom entry is recommended to prevent moisture from dripping onto the termination board.
•There must be a minimum of ½ inch (13 mm) of material between entry holes.
Field Wiring
The SP2 station provides terminal blocks on the termination PCBA, located in the rear enclosure, for field wiring the speaker
and RTU connections. The main PCBA, mounted to the back of the front panel, provides a pluggable terminal block for the
600-ohm audio connection. The POE interface PCBA, mounted on top of the main PCBA, provides a pluggable terminal
block for the POE connection (see Figure 3).
NOTE:The LINE OUT terminal block is not used in weatherproof stations. Make no connections to this terminal block.
1. Install spade lugs or ferrules on the wires before connection to the terminal blocks.
2. Torque the terminal block screws to 8–10 in·lb (0.90–1.13 N·m) when connecting spade lugged wires.
3. Connect the station enclosure to earth ground
1. Install a #6 ring lug on the ground conductor
2. Secure it to the ground terminal located in the lower right corner at the back of the rear enclosure (see Figure 1).
4. Terminate the direct speaker connection to terminal block TB1 on the termination PCBA.
5. Configure the speaker jumpers, P2 and P3, for the impedance of the connected speakers (see Figure 3).
6. Terminate the RTU inputs and output to terminal block TB2 on the termination PCBA.

Pub. 42004-789BQG
SP2 POE Weatherproof Handset/Speaker Amplifier Station Quick Installation Guide Page 3 of 4
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-xxxxQG Quick Guides\42004-789BQG.docx
01/20
7. Terminate the RTU power source to terminal block TB2on the termination PCBA.
8. Terminate the 600-ohm audio connections to terminal block TB1 on the main PCBA.
9. Terminate the POE connection to terminal block TB1 on the POE interface PCBA (see Figure 3).
NOTE:Maximum cable runs between SP2 stations and network switches are limited to 100 meters to comply with
Ethernet standards. Minimum cable specification is category 5e.
Figure 2. Suggested Wire Entry Locations

Pub. 42004-789BQG
SP2 POE Weatherproof Handset/Speaker Amplifier Station Quick Installation Guide Page 4 of 4
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-xxxxQG Quick Guides\42004-789BQG.docx
01/20
Figure 3. SP2 POE Weatherproof Connection Diagram
Front Panel Installation
After all terminations and adjustments are complete:
1. Place the front cover on the rear enclosure
Do not to pinch any cables.
2. Secure the front cover using the four screws and washers provided.
3. Torque the screws to 10–12 in∙lb (1.13–1.36 N∙m).
Reference Documentation
SP2 Configuration Guide..............................................................................................................................................42004-784
SP2 POE Weatherproof Handset/Speaker Amplifier....................................................................................................42004-789
Approvals
Electrical Safety..............................................................................................................................................................UL60950
CAN/CSA-22.2 No. 60950

(Rev. 10/06)
Warranty
Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any
GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall
be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability
of any such third-party warranty will be determined by GAI-Tronics.
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,
shall be performed in accordance with the standard of care with which such services are normally
provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided
hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above. Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be
responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return Policy
If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.
Other manuals for GAI-TRONICS SP2
9
This manual suits for next models
1
Table of contents
Other Hubbell Intercom System manuals