manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hunter
  6. •
  7. Measuring Instrument
  8. •
  9. Hunter HC User manual

Hunter HC User manual

Other manuals for HC

2

Other Hunter Measuring Instrument manuals

Hunter HC User manual

Hunter

Hunter HC User manual

Hunter Hydrawise Datasheet

Hunter

Hunter Hydrawise Datasheet

Hunter Hydrawise HC-1200M User manual

Hunter

Hunter Hydrawise HC-1200M User manual

Hunter HC Flow Meter User manual

Hunter

Hunter HC Flow Meter User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Connecting Your
Hydrawise Flow Meter
Thank you for purchasing a Hydrawise flow meter.
There are a few simple rules to follow to ensure that your
flow meter will give faultless service.
On the rear of this page you will find a Hydrawise
connection diagram and further helpful information is
available online at http://hydrawise.com/support.
Contents
The flow meter consists of 2 parts –
!Flow meter body
The flow meter body contains an analog dial for
manual readings as follows –
Dial Marking
Measurement Unit
X0.001
1 Litre
X0.01
10 Litres
X0.1
100 Litres
m3
Kilolitres
Your flow meter will have 3 wires protruding from the
flow meter’s body.
The wires need to be connected to the Sensor
inputs on the controller for remote measurement.
In all models only 2 wires are used.
"Adapter
Each flow meter has an optional adapter to allow
connection to smaller diameter pipes.
Model
Body Thread
Adapter Thread
1”
1” (25mm)
¾“ (20mm)
1¼”
1¼” (32mm)
1” (25mm)
Planning
Planning is an important step in the successful installation
of your Hydrawise flow meter and the reliable operation of
your irrigation system.
!Flow meter location
Flow meters are installed between the water supply
and the master valve. To avoid false alerts, there
should be no water taps or other uncontrolled water
use on the downstream side of the flow meter.
Where all the solenoids connected to the controller
are not grouped together, it may be necessary to
install more than one flow meter.
Where the flow meter is installed, do not have 90
degree bends within approximately 12 inches
(300mm) either side of flow meter.
"Cable
Two wire cable will be required.
The gauge of flow meter cable will be determined by
the total length of cable between the controller and
the flow meter.The general rule here is 0.5mm
(24GA) wire is good for a run of up to 240 feet (80
metres).
Installing
The following instructions assume you have already
installed your Hydrawise controller.
!Flow meter body
The flow meter has a marking on the body indicating
direction of water flow.
Installation of the flow meter must be in the correct
orientation with water flowing in the direction of the
arrow on the flow meter body.
"Connect flow meter wire
#Hydrawise strongly recommends that all flow
meter connections be soldered and sealed
against moisture for reliable, long term
operation.
Connect the wires as follows to your Hydrawise
controller –
Wire Color
Sensor Terminal Block
White
0V
Blue
Sensor 1, 2, 3 or 4
Red
Not used
Configuration
Configuration of your flow meter is completed using your
Hydrawise account.
!Log into your account
"Create a Flow Sensor
$Assign Zones to the Flow Sensor
Help: http://hydrawise.com/support or [email protected] HWCBI002A