82048 Turino Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
Installation Guide

43042-01 02/21/2008
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the
fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a
soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove
motor plate, find the single tab on the motor plate (located next to the recepta-
cle). Push up rear motor plate tab while pushing out on the side of the housing
or insert a screwdriver into the slot in the housing (next to tab) and twist screw-
driver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN
WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bear-
ings are making excessive or unusual
noises, replace the motor with the exact service motor. You should replace the
impeller at the same time.
1. Use this unit only in a manner intended by the manufacturer. If
you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch power off at ser-
vice panel and lock the service disconnecting means to prevent
power from being switched on accidentally. when the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting
of gasses through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards,such as those published
by the National Fire Prevention Association (NFPA), and the
American Society for Heating, Refrigeration and Air-Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. Install fan at least 5 feet (1.52 m) above the floor.
10. This unit must be grounded.
11. Unit must not be installed in a ceiling thermally insulated to a value
greater than R40.
DISCONNECT ELECTRIC
POWER SUPPLY
AND LOCK OUT
SERVICE PANEL BEFORE
SERVICING UNIT
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy/unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power
unit.
3. DO NOT install this product in a wall. This product is
designed for installation in ceilings up to a 12/12 pitch (45
degrees). Ductwork must point upward.
4. Please read specification label on product for further infor-
mation and requirements.
Do Not Install Above
Or Inside This Area
Cooking
Equipment
Floor
45° 45°
WARNING
!
WARNING
!
COOKING AREA
CAUTION
!
ENGLISH

43042-01 02/21/2008
3
D95044-01-000
N75184-01-133
L97959-01-000
K65219-01-000
J77521-01-000
E95029-01-000
A
x4
F75191-01-000
G03242-07-133
I
H
74508-03-133
98037-01-000
x2
O97960-01-000
M75729-01-000
P77535-01-000
Check all the parts.
If damaged, call
1-888-830-1326
for replacements.
Tools Needed.
Estimated assembly time: 30 to 60 minutes
Included.
B
*C
*
3/8” Cable Connector
Extra Screws
I
x2
*
NOTE: Strain relief cable connector must be installed. Not Included.
ENGLISH

43042-01 02/21/2008
4
Remove the motor/blower from the housing.
Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush
with the side of the housing.
Remove packing material.
Turn off the power source.
Before Installation
Loosen screws.
NOTE: Remove all packing materials before installation.
12
3
5 6
4
H
H
I
E
ENGLISH

43042-01 02/21/2008
5
7
G
Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and
secure with the washer.
Remove the wiring cover screw. Remove the wiring cover.
Choose Installation Option
For New Construction - attaching to joist fo to step A11, page 6
For New Construction - suspended between joists go to step B11, page 8
For Existing Construction - accessible from above go to step C11, page 11
For Existing Construction - accessible only from below go to step D11, page 15
8F
9
E
10
B
C
ENGLISH

43042-01 02/21/2008
6
5/8
1/2
A11
A13
A12
E
Connect wires as shown.
Pull wires through the strain relief.
Position the correct depth mark at the bottom edge of the joist
based on the thickness of your sheetrock.
New Construction – attaching to joist
Screw pre-loaded screws into joist or framing.
A14
F
A
Fan Motor
Light
2 Pin
Black
Ground
Green
Bare Copper
White
Black Main Switch 1 (AC In)
Black Switch 2 (AC In)
Black Light
*Option
White
White
3 Pin
*Option Fan & Main Light Together
ENGLISH

43042-01 02/21/2008
7
0000
0000
0
A15
A18
A20
A19
A17
A16
F
H
I
G
E
Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into
position. Make sure the wires are not pinched
between the motor and the housing.
Secure the motor by tightening the 2 screws. Turn on the power source.
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
ENGLISH

43042-01 02/21/2008
8
5/8
1/2
5/8
1/2
1/8" Bit
Slide the mounting rails into brackets.
Mark position of screws by using holes as a template.
New Construction – suspended between joists
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
Drill a hole in the center of each outline.
Test the motor. If the motor does not run, check the plug
connection.
A22
E1
Go to step
on page 18
to attach grille.
A21
B11
B13 B14
B12
D
E
E
ON
OFF
ENGLISH

43042-01 02/21/2008
9
Connect wires as shown.
Tighten screws. Pull wires through the strain relief.
Insert screws, leaving space between the screw
head and the joist. Screws are not provided.
Attach the rails onto the screws.
B15 B16
B17 B18
B19
F
A
Fan Motor
Light
2 Pin
Black
Ground
Green
Bare Copper
White
Black Main Switch 1 (AC In)
Black Switch 2 (AC In)
Black Light
*Option
White
White
3 Pin
*Option Fan & Main Light Together
ENGLISH

43042-01 02/21/2008
10
Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into
position. Make sure the wires are not pinched
between the motor and the housing.
Turn on the power source.
Secure the motor by tightening the 2 screws.
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
wiring cover plate.
B20
B22
B24
B22
B25
B21
F
G
H
I
H
ENGLISH