P500 Installation (Cont’d)
Inlet Piping
Provide for permanent or temporary installation of a compound
pressure gauge to monitor the inlet pressure. To maintain
maximumow,thepumpinletshouldbeunderoodedsuction
conditionsatalltimes.Do not supply more than one pump
from the same inlet line.
Supply Tank
Useasupplytankthatislargeenoughtoprovidetimeforany
trappedairintheuidtoescape.Thetanksizeshouldbeat
leasttwicethemaximumpumpowrate.
Installaseparateinletlinefromthesupplytanktoeachpump.
Placeacoveroverthesupplytank,topreventforeignobjects
fromfallingintoit.
Hose Sizing and Routing
Tominimizeacceleration head andfrictionallosses,sizethe
suctionlineat least one sizelargerthanthe pump inlet,and
keepthesuctionlineasshortanddirectaspossible.
Recommendations:
• Keepinletlineslessthan3ft.(1m)long
• Useatleast1-1/2”(38mm)I.D.inlethose
• Minimizettings(elbows,valves,tees,etc.)
Inlet Piping (Pressure Feed)
Provide for permanent or temporary installation of a pressure
gaugetomonitortheinletpressure.Pressureatthepumpinlet
shouldnotexceed500psi(35bar).Forhigherpressuresinstall
apressurereducingvalve.Do not supply more than one pump
from the same inlet line.
Note: System back pressure must exceed the pump inlet
pressure by at least 15 psi (1 bar) in order to prevent ow
thru.
Discharge Piping
Hose and Routing
Usetheshortest,most-directrouteforthedischargeline.
Selectpipeorhosewithaworking pressure ratingofatleast
1.5timesthemaximumsystempressure.Example:Selecta
1500psi(103bar)W.P.-ratedhoseforsystemstobeoperated
at1000psi(69bar)gaugepressure.
Supportthepumpandpipingindependently.
Pressure Regulation
Install a pressure relief valve in the discharge line. Bypass
pressuremustnotexceedthepressurelimitofthepump.
Sizethevalvesothat,whenfullyopen,itwillbelargeenough
torelievethefullcapacityofthepumpwithoutover-pressurizing
thesystem.
Locate the valve as close to the pump as possible and ahead
ofanyothervalves.
Adjustthepressurereliefvalvetonomorethan10%overthe
maximumworkingpressureofthesystem.Donotexceedthe
manufacturer’spressureratingforthepumporvalve.
Routethebypasslinetothesupplytank.
CAUTION: Never install shuto valves in the bypass line
or between the pump and pressure regulator or relief valve.
Provide for permanent or temporary installation of a pressure
gaugetomonitorthedischargepressureatthepump.
Minimum Discharge Pressure
To ensure proper capacity control, a minimum discharge
pressureof50psi(3.5bar)isrequired.
Safety Precautions
General remarks
These safety / installation instructions contain fundamental
informationandprecautionarynotesandmustbekeptavailable
toallassociatedwiththeoperationofthepump.Pleaseread
themthoroughlypriortoinstallation,electricalconnectionand
commissioningoftheunit.Itisimperativethatallotheroperating
instructionsrelatingtothecomponentsofindividualunitsare
followed.
These safety / installation instructions do not take local
regulationsintoaccount.Theoperatormustensurethatsuch
regulationsareobservedbyall,includingthepersonnelcarrying
outtheinstallation.
Each pumpmustbe labeled bythe end userto warnofany
hazardsthatthesystemprocessmayproduce;e.g.corrosive
chemicalsorhotprocessetc.
All personnel involved in the operation, maintenance, inspection
andinstallationofthepumpmustbefullyqualiedtocarryout
the work. The personnel’s responsibilities, competence and
supervisionmustbeclearlydenedbytheoperator.Totheextent
thatifthepersonnelinquestionisnotalreadyinpossession
oftherequisiteknowhow,appropriatetrainingandinstruction
mustbeprovided.Inaddition,theoperatorisresponsiblefor
ensuringthatthecontentsoftheoperatinginstructionsarefully
understoodbyalltheresponsiblepersonnel.
WheninstallingaHydra-Cellpumpinconjunctionwithamotor
ormotorandfrequencycontrollertherelevantmanualsmust
bereferredtoforelectromagneticcompatibility.Theinstallation
shouldconformtoEN61800andEN60204asapplicable.
All safety instructions in this manual and all relevant local health
andsafetyregulationsmustbefollowed.
Attention must be paid to the weight of the pump before
attemptingtolifteithermanuallyorselectingappropriatelifting
equipment.