Hydrel TPS RGB SERIES User manual

1. Please refer to ABL General Warnings Form no. 503.204 and 503.203.
2. Be sure the power is off at the supply source.
3.
4.
Mount the Fixture Yoke to mounting accessory, using the SS3/8-16 fastener (D) provided.
(Mounting accessories sold separately)
Route fixture cord and data cord through cord seals provided with Hydrel mounting accessory
(except wall plates, those require remote junction boxes by others - see page 2). Tighten the cord
seal outer nut and then thread the cord seals into the mounting accessory. Make all wiring
connections to the fixture within the mounting accessory. Note: Make sure that there is enough
cord left free for aiming of the fixture.
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
INSTALLATION INSTRUCTIONS
TPS RGB SERIES YOKE MOUNT
ATTENTION: DISCONNECT POWER BEFORE SERVICING
WARNING - TO REDUCE RISK OF FIRE, USE APPROPRIATE LAMP
Lamp information is found inside luminaire. Removing the reflector may be necessary to view lamp information.
SUITABLE FOR WET LOCATION
MINIMUM 90°C SUPPLY CONDUCTORS
LES FILS D’ALIMENTATION DOIVENT CONVENIR POUR 90°C
p
!
©2016 Acuity Brands Lighting, Inc.
6/27/2017
INS-TPS_RGB
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice.
Any dimension on this sheet is to be assumed as a reference dimension:
“Used for information purposes only. It does not govern manufacturing or
inspection requirements.” (ANSI Y14.5-1973)
9144 Deering Avenue | Chatsworth, CA 91311
Phone: 866.533.9901 | www.hydrel.com
Fixture comes standard with 10' of STW cable
and 10' of DMX data cable.
DMX
LINE
CAUTION: DMX data cord comes insulated, it is not recommended that this be cut in the field or it will expose the bare metal shield wire which
can then short to ground causing data transmission issues up to complete fixture failure. Cutting the data cable in the field will void warranty.

TPS RGB SERIES YOKE MOUNT
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice.
Any dimension on this sheet is to be assumed as a reference dimension:
“Used for information purposes only. It does not govern manufacturing or
inspection requirements.” (ANSI Y14.5-1973)
9144 Deering Avenue | Chatsworth, CA 91311
Phone: 866.533.9901 | www.hydrel.com
MOUNTING ACCESSORIES
Power
DMX
SMSA/PSSA
Stanchion Mounts - 12" - 48"
Pedestal Stanchion 7"
EWM
Extended Wall Mount
18" - 36" Length
A
B
C
F
D
DMX Data line
Power line
TPS Series Yoke Mount Fixture
Mounting Accessory (ordered separately)
SS 1/4-20 Fasteners
SS 3/8-16 Fastener
1/2” NPT Cord Seal Fastener Assembly SS
1/4-20 Yoke Fasteners - aiming
instructions on page 5
A
B
C
D
E
F
Mounting accessories will come with 2 threaded
opening, one for the DMX data line and one for
the power.
PARx/xx, PASx/xx
Pole Mounting Arms 12" -
24" Length
PATRx/xx &PATSx/xx
double arms also available
ARTL
Archtiectural Junction
Box - 6.8"
©2016 Acuity Brands Lighting, Inc.
6/27/2017
INS-TPS_RGB

TPS RGB SERIES YOKE MOUNT
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice.
Any dimension on this sheet is to be assumed as a reference dimension:
“Used for information purposes only. It does not govern manufacturing or
inspection requirements.” (ANSI Y14.5-1973)
9144 Deering Avenue | Chatsworth, CA 91311
Phone: 866.533.9901 | www.hydrel.com
DMX WIRING DETAIL
DMX WIRING DETAIL
SUPPLY POWER - LINE VOLTAGE
POWER FROM FIXTURE
DMX DATA FROM FIXTURE
(TO NEXT FIXTURE)
DMX LINE FROM NEXT FIXTURE
(DMX+ IN)
(DMX- IN)
DMX+ OUT
to
DMX+ IN
(SHIELD/GROUND BARE)
DMX RGB - DOUBLE CORD TO DOUBLE CORD
DMX- OUT
to
DMX- IN
DMX IN lines are
connected to the
previous fixture or
the controller
©2016 Acuity Brands Lighting, Inc.
6/27/2017
INS-TPS_RGB

Fixture
1
Fixture
2
Fixture
10
Power (120-277V AC)
Up to 32 Fixtures
Per DMX Line
DMX Splitter
(optional depending on installation
(by others)
128 Fixtures total
per DMX Universe
DMX Console
(ordered separately)
Easyl Pro controller
by Acuity is the
recommended
console
DMX System - Flood
Notes:
1. DMX512 must be terminated by a 120 ohm resistor.
Up to 32 Fixtures Per DMX Line - if there are more than 32
fixtures use a splitter to create a new bus.
DMX512 Bus network may
be no more than 1,000 feet
(300 meters) with no more
than 32 devices per bus.
2. Signal cable by others, cable must be two-pair with a
maximum capacitance of12.8 pF/ft. and a impedance
of 120 ohm.
9144 Deering Avenue, Second Floor • Chatsworth, CA 91311 • www.hydrel.com
Phone: 866.533.9901 • Fax: 866.533.5291
Parallel bus for
more than 32
luminaires
Mounting
Mounting
etc.
See page 3 for wiring
detail inside
mounting accessory/
J-box
DMX IN
OUT
OUT
OUT
IN
120 OHM
Power Wire
M ounting
©2016 Acuity Brands Lighting, Inc.
6/27/2017
INS-TPS_RGB

*Yoke Locks may become fully engaged in fixture head during shipment or after installation and not allow for fixture
re-aiming. This is a normal operation and may require the Yoke Locks to be dis-engaged for re-aiming.
To dis-engage Yoke Locks:
- Loosen Yoke Lock center fasteners on each yoke lock
2 - Locate Yoke Lock/Fixture interface disengagement slots. Slots are located perpendicular to yoke axis (Fig.1)
- Insert large flat blade screwdriver into slots and pull screwdriver handle away from fixture body releasing the
Yoke Lock.
- Adjust fixture and re-tighten center Yoke Lock fasteners.
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION
WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a
reference dimension: “Used for information purposes only. It does not
govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
TPS SERIES YOKE MOUNT
AIMING
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
INSTALLATION INSTRUCTIONS
ATTENTION: DISCONNECT POWER BEFORE SERVICING
WARNING - TO REDUCE RISK OF FIRE, USE APPROPRIATE LAMP
Lamp information is found inside luminaire. Removing the reflector may be necessary to view lamp information.
SUITABLE FOR WET LOCATION
MINIMUM 90°C SUPPLY CONDUCTORS
LES FILS D’ALIMENTATION DOIVENT CONVENIR POUR 90°C
p
!
YOKE ADJUSTMENT DIAGRAM
A
B
C
D
ABC D
9144 Deering Avenue | Chatsworth, CA 91311
Phone: 866.533.9901 | www.hydrel.com
©2016 Acuity Brands Lighting, Inc.
6/27/2017
INS-TPS_RGB
Table of contents
Popular Light Fixture manuals by other brands

Lightolier
Lightolier PENDALYTE SERIES Instructions for maintenance reference

Haneco
Haneco ESODO BOX 24M installation guide

Uplus Lighting
Uplus Lighting MINI740 user manual

SOLAR VISION
SOLAR VISION LX25 installation manual

Larson Electronics
Larson Electronics IND-AHF-BX-UVC-R2-120V-15C instruction manual

Elgato
Elgato RING LIGHT Reviewer's guide