HyperSound Clear 500P User manual

Amplifier / Control Unit (1)
A
HyperSound®Speakers (2)
B
Optical (Toslink)
Audio Cable (1)
D
Floor Stand Tool
(Allen Wrench) (1)
F
RCA Audio Cable (1)
E
Remote & AAA
Batteries (1)
C
Power Supply (1)
G
H
Floor Stand Poles (2)
Quick Start Guide
PACKAGE CONTENTS
CONNECTIONS
With Floor Stand Poles Without Floor Stand Poles
SPEAKER CONFIGURATION
Notes: Some TV’s have settings in the menu which control the audio output. Refer to your
TV manufacturer's manual and make sure the following, if available, is configured.
• Audio out or Digital out, is set to: ON
• Audio out Volume Control is set to: Fixed
• Audio out format or type is set to: Dolby Digital or PCM
Information on alternative RCA Connections available in the User Guide.
Not Included: HDMI Cables
Not Included: HDMI Cables, Secondary Optical Audio Cable
Not Included: HDMI Cables, Secondary
Optical Audio Cable
Not Included: HDMI Cables
Primary Connection (Used if AV Receiver does not have Digital Out)
Alternative Connection (Used if AV Receiver has Digital Out)
Sound Bar Setup
HDMI Cable
HDMI Cable
Optical Audio Cable
Optical Audio Cable
DVD/Blu-Ray Player
Sound Bar
TV
Power
Cable/Satellite Box
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
Digital Out
HyperSound Clear™ 500P
Power Supply
Optical Audio Cable
DVD/Blu-Ray Player
TV
Power
Cable/Satellite Box
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
Digital Out
Power Supply
HyperSound Clear™ 500P
Direct to TV Setup
HDMI Cable
HDMI Cable
HDMI Cable
HDMI Cable
Optical Audio Cable
Optical Audio Cable
DVD/Blu-Ray Player
TV
Power
Cable/Satellite Box
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
Digital Out
Digital Out
HyperSound Clear™ 500P
Direct to Media Setup
Power Supply
Optical (Toslink)
Audio Cable
RCA Audio Cable
(For alternative setup)
Cables Needed:
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
HyperSound Clear 500P™
SPEAKER CONNECTIONS
HyperSound®Speaker HyperSound®Speaker
Optical Audio Cable
Optical Audio Cable
TV
Power
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
Digital Out
Digital Out
HyperSound Clear™ 500P
Direct to AV Receiver Setup*
HDMI Cable
HDMI Cable
HDMI Cable
DVD/Blu-Ray Player
Cable/Satellite Box
AV Receiver
Power Supply
Refer to HyperSound Clear™ 500P User Guide for Complete Instructions.
For Floor Stand Assembly Please Refer to the User Guide.
1. Turn Counter-clockwise
to Loosen.
2. Insert Wire.
3. Turn Clockwise to Tighten.
*Most AV Receivers must have “Audio Pass Through” to
the TV turned ON first before audio can be sent to the
HyperSound Clear™ 500P from the TV.
OPTICAL 1 OPTICAL 2
ANALOG IN
48VDC
OUTPUTINPUTS
OPTICAL WOOFER
HYPERSOUND EMITTERS ONLY
RIGHT LEFT
Remove Protective Caps
on Optical Cables and
HyperSound Clear™
Speaker.
Protective Caps Protective Caps
Power Supply

Power
(Illuminated white
when on. Yellow
when off.)
Power Inputs
Mute
Volume
Up / Down
Center = Select
Directional Keys
Volume Control
·= Directional keys
Center = Select
AUX
Input
OLED Display
FRONT PANEL CONTROLS DIAGRAM
REMOTE CONTROL DIAGRAM
WARNINGS
ALIGNMENT
HyperSound®Audio
Area of no effect
Area of no effect
Area of enhanced clarity
Area of no effect
Sit in your intended location and adjust the HyperSound Clear™ speakers until you can see your reflection centered in each speaker.
Choose from four available Equalizer Settings. Two additional EQ settings may also be programmed by a hearing health care
professional based on your personal hearing level. Visit www.hypersoundhearing.com/locations to find a provider. • Important warning for wearers of hearing aids - Because HyperSound audio is focused, you may need to decrease the volume
or sensitivity of your hearing aid if you feel that the sound is too loud or you experience any acoustic feedback (squeal or
whistle sound) or any other sound artifacts in the ears. If you are unable to adjust your hearing aid and you are experiencing
any discomfort to your ears while listening to HyperSound Clear, please remove your hearing aids, step outside of the
HyperSound sound zone, or discontinue use of the HyperSound Clear with your hearing aid.
• Never hold a speaker up to your ear. Maintain at least 18 inches (0.5 meter) distance between the speaker and any listener.
• Hazard Warning! High Voltage. This situation or condition can cause injury due to electric shock. NEVER OPERATE THE
APPARATUS WITH THE FRONT GRILL OF THE SPEAKER REMOVED, HIGH VOLTAGES ARE PRESENT.
• Oxygen vigorously accelerates combustion. Do not operate the apparatus in an environment with flammable gases or liquids.
• HyperSound Clear should be installed and used under adult supervision. The product packaging includes plastic bags and
small parts that could create a choking risk. Quickly and safely discard plastic bags, twist ties, protective plastic film, and
protective caps on the optical cables and connectors.
Review all warnings, cautions, and detailed procedures in the HyperSound
Clear™ 500P User Guide before using your new directed hearing solution.
• Pressing Select when Equalizer is highlighted takes you to the
Equalizer setting menu.
• Use Up/Down buttons to get to the Equalizer setting desired and hit Select.
• Standard mode is flat across all frequencies.
• Bright 1, Bright 2 and Bright 3 emphasize higher frequencies.
• Personal 1 and Personal 2 are available only when programmed by a hearing
health care professional.
For Support Contact: 888-496-8001 or
visit www.hypersoundhearing.com.
OPTICAL 1
OPTICAL 2
RCA - Back
AUX- Front
Area of no effect
Area of no effect
Area of enhanced clarity
HyperSound®Audio
VOLUME = 12
MUTE ON
MUTE OFF
ACTIVE
INITIATING
REPLACING REMOTE CONTROL BATTERIES
1. Remove Battery Cover 2. Insert 2 AAA batteries 3. Replace Battery Cover
426-008-004-001RA
Top-down View Side View
EQUALIZER SETTINGS
© 2016 Turtle Beach Corporation (“TBC”). All rights reserved. HYPERSOUND CLEAR and the HyperSound logo are proprietary trademarks of TBC. Manufactured under license
from Dolby Laboratories. Dolby and the double-D symbol are trademarks of Dolby Laboratories. All other trademarks are properties of their respective owners.
Be sure to select the Input that matches your
Input connection method.
EQUALIZER
BRIGHT 3
BRIGHT 2
PERSONAL 2
PERSONAL 1
BRIGHT 1
STANDARD
Primary Connection (Used if AV Receiver does not have Digital Out)
Alternative Connection (Used if AV Receiver has Digital Out)