Preface
PrefacePreface
Preface
We thank you for selecting the Hypex UcD Supply HG
Hypex UcD Supply HGHypex UcD Supply HG
Hypex UcD Supply HG Mono
Mono Mono
Mono and recommend
that you read these instructions carefully before installation and start-up of the
supply Please keep this manual in a safe place for future reference
Tested
TestedTested
Tested
Committed to quality, Hypex individually tests each product to ensure reliable
performance for the user All units have passed the quality control standards of
Hypex Electronics B V and conform within tolerance to the enclosed
specifications
About
AboutAbout
About Hypex Electronics B V
Hypex Electronics B V Hypex Electronics B V
Hypex Electronics B V
Hypex Electronics B V is located in Groningen, the Netherlands
Hypex Electronics B V has been designing, manufacturing and supporting audio
amplifier equipment since 1995 Hypex Electronics B V main markets are the
EC Countries, United States and Australia
Hypex Electronics B V
Kattegat 8
9723 JP Groningen
The Netherlands
Phone: +31 (0)50 5264993
Fax: +31 (0)50 5254591
Email: info@hypex nl
http://www hypex nl
Copyright Hypex Electronics B V All rights reserved; reproduction without permission prohibited
This manual may be subject to change; no liability can be accepted for any error or omission
1
11
1
Safe
SafeSafe
Safety Rules
ty Rulesty Rules
ty Rules
1 1
1 11 1
1 1
General
GeneralGeneral
General
- This equipment can be operated by anyone with basic knowledge of
Electronics and understands the danger of AC and especially DC voltages
- WARNING: RISK OF ELECTRICAL SHOCK
WARNING: RISK OF ELECTRICAL SHOCK WARNING: RISK OF ELECTRICAL SHOCK
WARNING: RISK OF ELECTRICAL SHOCK
- Dangerous voltages are present during operation The DC-output voltage
may be more than 2 x 60 Volt (120 Volt DC total)
1 2
1 21 2
1 2
Installation
InstallationInstallation
Installation
- The amplifier power supply is intended to be used in normal domestic
situations
- Do not use the power supply in an excessively humid environment or near
water
- The unit must be placed in a sufficiently ventilated area; the ambient
temperature should not exceed 30°C
- Do not connect any equipment other than the intended audio amplifiers to
the power supply
- All hazardous voltages may never be accidentally touched
All hazardous voltages may never be accidentally touchedAll hazardous voltages may never be accidentally touched
All hazardous voltages may never be accidentally touched after
after after
after
installation and during use
installation and during useinstallation and during use
installation and during use
2
22
2
F
FF
Functional explanation
unctional explanationunctional explanation
unctional explanation
2 1
2 12 1
2 1
The Principles of Operation
The Principles of OperationThe Principles of Operation
The Principles of Operation
The UcD Supply HG Mono converts the AC voltage into suitable DC voltage for
powering UcD amplifiers
The typical AC input voltage depends on the DC voltage requirements of the
connected amplifier and must come from a double insulation class-2 transformer
for safety reasons This transformer must be primary fused In case of high inrush
currents a current limiter PCB is recommended
2 2
2 22 2
2 2
Normal Conditions
Normal ConditionsNormal Conditions
Normal Conditions
The DC output voltage will vary depending on output power and transformer and
should not exceed the limits of the connected amplifier for normal use
Typical AC-input voltage for UcD180 Amplifier: 2 x 31 Vac
Typical AC-input voltage for UcD400 Amplifier: 2 x 42 Vac
3
33
3
Functional description
Functional descriptionFunctional description
Functional description
See diagram last page
The main input voltages from the transformer are wired to Faston connectors
J7/J8/J9 (J22)
If desired, auxiliary supply can be connected to J12/J13/J14 This low voltage,
low power connection can be used for pre-amplifier use Maximum current:
100 mA
A LED may be connected as POWER-ON indicator
The UcD Supply has DC-protection circuitry thus allowing the amplifier to shut
down quickly after such an event
The amplifier can be controlled switched on/off by the UcD supply; completely
‘pop-free’
Two fuses are mounted to protect in case of over current in the main power
circuit These fuses must be <=4 Amp/250Volt fast type Last, but not least, 2x
Slit Foil Capacitors are fitted for optimal audio performance
4
44
4
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
Type : UcD Supply HG Mono
AC input voltage : Typical 2 x 42 Vac
Input frequency : 50/60 Hz
DC output voltage : 2 x 57 Vdc (at typical input voltage)
Main PCB fuses F1, F2 : maximum 4 Amp fast / 250V - 5x20mm
Auxiliary AC-supply : Typical 14-0-14 Vac (between 11 and 16 vac)
Auxiliary DC-output : +12V/0V/-12V maximum current 100 mA
GENERAL DESIGN CRITERIA
GENERAL DESIGN CRITERIAGENERAL DESIGN CRITERIA
GENERAL DESIGN CRITERIA
Humidity : 95% non-condensing
Safety : EN 60065
EMC : EN 55103

Popular Control Unit manuals by other brands

Paser uDAB KIT052USHY22 manual

Paser

Paser uDAB KIT052USHY22 manual

TP-Link TL-SM311 Series installation guide

TP-Link

TP-Link TL-SM311 Series installation guide

Digiflex RF160 Installer's reference guide

Digiflex

Digiflex RF160 Installer's reference guide

Nibe VVM S320 user manual

Nibe

Nibe VVM S320 user manual

Emerson QC54 FOUNDATION installation guide

Emerson

Emerson QC54 FOUNDATION installation guide

CALEFFI 642 Series manual

CALEFFI

CALEFFI 642 Series manual

Paul TAC4 DG + TCP Installation and Maintenance

Paul

Paul TAC4 DG + TCP Installation and Maintenance

Yoshitake GPK-2001 Installation & operation manual

Yoshitake

Yoshitake GPK-2001 Installation & operation manual

Grundfos CIM 500 Installation and operating instructions

Grundfos

Grundfos CIM 500 Installation and operating instructions

VSpeak VSpeak for JR PROPO manual

VSpeak

VSpeak VSpeak for JR PROPO manual

TEC 100 Programming & installation manual

TEC

TEC 100 Programming & installation manual

Bosch Rexroth DBET operating instructions

Bosch

Bosch Rexroth DBET operating instructions

Stahl 9475/32-08 2 Series operating instructions

Stahl

Stahl 9475/32-08 2 Series operating instructions

YASKAWA VIPA System SLIO manual

YASKAWA

YASKAWA VIPA System SLIO manual

APARIAN IP Point HART quick start guide

APARIAN

APARIAN IP Point HART quick start guide

Ebyte EA01-S user manual

Ebyte

Ebyte EA01-S user manual

Rexroth Indramat Mannesmann Rexroth CLM-01.3-M user manual

Rexroth Indramat

Rexroth Indramat Mannesmann Rexroth CLM-01.3-M user manual

BTR BCR - 2 A Installation and commissioning instructions

BTR

BTR BCR - 2 A Installation and commissioning instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.