HYXIPOWER HYX-DMU-W User manual

User Manual
HYX-DMU-W/4G
DATA
MANAGEMENT
UNIT
Carefully read this inverter user instructions before using.
Read and save these instructions.

HYX-DMU-W/4G User Manual
© 2023 ZHEJIANG HYXI TECHNOLOGY CO., LTD. All rights reserved.
This document cannot be copied fully or partially, transferred, or distributed in any form without
the prior written permission of ZHEJIANG HYXI TECHNOLOGY CO., LTD (hereinafter referred to as
"HYXIPOWER").
TRADEMARKS
and other HYXIPOWER trademarks are the trademarks or registered trademarks of HYXIPOWER All
other trademarks mentioned herein are the properties of their respective owners.
i

HYX-DMU-W/4G User Manual Contents
Contents
Preface.....................................................................................................................................................................1
Overview .................................................................................................................................................................1
Scope of Application............................................................................................................................................1
Safety Instructions...............................................................................................................................................1
1. Product Overview .......................................................................................................................................... 3
..........................................................................................................................................................3
.......................................................................................................................................................................3
................................................................................................................................3
.....................................................................................................................................................................3
.............................................................................................................................................................4
.........................................................................................................................................................4
......................................................................................................................................................4
..............................................................................................................................................................5
...........................................................................................................................................................5
........................................................................................................
............................................................................................................................................................................
...............................................................................................................................................................
...........................................................................................................
2. Installation......................................................................................................................................................... 7
............................................................................................................................................................
..........................................................................................................................................................................
...........................................................................................................................................................................
..................................................................................................................
.......................................................................................................................................................
................................................................................................................................................
3. Human-Computer Interaction ....................................................................................................................12
Installing the App..............................................................................................................................................................
.............................................................................................................................................................
..........................................................................................................................................................
4. Appendix...........................................................................................................................................................13
........................................................................................................................................................ 13
..................................................................................................................14
................................................................................................................................................................15
.......................................................................................................................................................15
ii

HYX-DMU-W/4G User Manual
1
Preface
Overview
This manual provides users with the product information of the data management unit (DMU)
communication system device. Product information, detailed installation and usage, fault
diagnosis and daily maintenance related precautions, does not include all information about the
photovoltaic system.
To ensure the DMU communication system device can be correctly installed and used, and
give full play to its superior performance. Before handling, installing, operating and maintaining
the DMU, please read the instruction manual carefully and follow all safety precautions in the
instruction manual.
Scope of Application
This manual is intended for the following devices:
• HYX-DMU-W
• HYX-DMU-4G
Hereinafter, unless otherwise specified, it is referred to as "DMU" for short.
Safety Instructions
In order to ensure the user's personal and property safety when using the product, and to use
the product more efficiently and optimally, the manual provides relevant information and are
highlighted using the following symbols.
The symbols that may be used in this manual are listed below, please read carefully to use this
manual better.
• This symbol indicates a hazardous situation which may present a risk of fatal
electric shock, serious personal injury or fire.
• This symbol indicates that instructions must be followed strictly to avoid a potential
safety hazard.
• This symbol indicates that the operation is prohibited and the person concerned
should discontinue the operation.
Preface
DANGER
CAUTION
NOTICE

HYX-DMU-W/4G User Manual
Preface
Note that only professionals should install or replace the DMU.
Do not attempt to repair the DMU without Hyxi’s permission, otherwise it will affect the
warranty of the device. If any DMU is damaged, please send the DMU back to Hyxi’s dealer for
repair or replacement.
Please read all instructions and warnings in this manual carefully.
Please use the device according to the installation or usage method described in this document,
Symbol
Description
Do not dispose of the inverter as household waste.
The symbol indicates DC voltage.

HYX-DMU-W/4G User Manual
3
1. Product Overview
This chapter mainly introduces the DMU appearance, packaging accessories, technical
parameters, etc.
PV microinverter system
Microinverter (hereinafter referred to as microinverter) converts the DC output of PV panels
DMU continuously collects the operating data of each microinverter port and sends it to the
hardware base.
The DMU data management unit is a key component of the microinverter system. It is the
power generation information transfer station of the microinverter system, which communicates
operation data of the microinverter, and sends the collected microinverter operation data
through Ethernet to Hyxi monitoring service system.
A single DMU data management unit can communicate up to 400 PV modules, i.e. it can
or 100 4-in-1 series of microinverters. If the DMU data management unit is installed in a place
with poor communication signal the environment may cause signal attenuation, resulting in the
reduction of communication devices.
•
in the user manual. The execution is performed, and the distance between the
microinverter and the DMU is as close as possible to reduce obstruction.
This article mainly involves the following product models:
• HYX-DMU-W
• HYX- DMU-4G
1. Product Overview
CAUTION

HYX-DMU-W/4G User Manual
4
The monitoring system collects the operating data and status of each microinverter in the
system through the DMU data management unit, and uses the PC or APP to provide users with
components, microinverters, DMU data management unit and other devices.
1. Product Overview

HYX-DMU-W/4G User Manual
5
working status of the DMU.
No. Description
DRM port
Ethernet port
Power port
Reset button
4G antenna
No. Description
A
B
C
DDRM port
EEthernet port
GPower port
Reset button
No.
APOWER
BNET
CCOM.
DALARM
1. Product Overview
J
A
B
C
D

HYX-DMU-W/4G User Manual
•
•
•
•
generated power from being transmitted to the grid.
•
to the grid, but within a certain range.
•
display PV power generation and local power consumption.
The DMU is connected to external control device through the standard RJ-45 port, and the
microinverter.
No. Description Device status
APower indicator ON Power on
Power off
BNetwork communication
(connecting to the server)
Normal
Abnormal
CMicroinverter communication
(connecting to microinverter)
Normal
Abnormal
D ON Abnormal
Normal
1. Product Overview
No. Description
DRM0 Disconnect the device
DRM1
Do not use more than 50% of the rated power
DRM3
DRM4 Increased electrical power usage (subject to other active DRMs)
DRM5
Generating power should not exceed 50% of rated power
reactive power
Increased power generation (subject to other valid DRMs)

HYX-DMU-W/4G User Manual
2. Installation
The device has been fully tested and strictly inspected before leaving the factory, but damage
may still occur during transportation, please conduct a detailed inspection before signing for
the product.
• Check the box for damage.
• Check whether the goods are complete and in accordance with the order according
to the packing list.
• Unpack and check that all device inside is intact.
• Check whether the products in the box are in accordance with the packing list
guide, etc.).
• If there is any damage or incomplete goods, please contact the shipping company
or contact Zhejiang Hyxi Technology Co., Ltd. directly, and provide photos of the
damage to facilitate service.
• Do not discard the original packaging of the device. It is best to store it in the
original packing box after the device is out of service and disassembled.
• Has a standard AC outlet
• Router/LAN/4G network with Ethernet interface.
Name Quantity Unit
Power adapter 1
Green terminal 1PC
Installation map 1PC
Quick installation guide 1PC
1PC
Mount 1PC
1
4PC
PC
PC
NOTICE

HYX-DMU-W/4G User Manual
•
•
• It is forbidden to install it where children can reach it.
Step 1:
hear a sound of "click".
CAUTION
4G mode Cable mode
Microinverters.
on the DMU.
a monitoring platform.
status.
view the operation status of
the power station.

HYX-DMU-W/4G User Manual
•
• he wireless network account password to the DMU through the APP, see
chapter XX for details
• Cable mode: Insert one end of the cable into the Ethernet port of the DMU, and the
other end into the broadband router port.
•
• If the DMU data management unit is installed in a metal box or under a metal
please contact Hyxi or local distributors for purchase (please contact Hyxi technical
support).
• support@hyxipower.
com.
NOTICE
Ethernet
Cable mode
NOTICE

HYX-DMU-W/4G User Manual
10
• Installing on the roof can increase the signal strength.
• Installed in the center of the PV array.
•
• Do not mount the DMU directly above metal or concrete to prevent signal
attenuation.
Note: You need to prepare yourself: marker pens, electric drills, screwdrivers and other tools.
• Hang the mount on the wall, adjust the angle, and mark it with a marker pen.
• Drill the hole at the mark using the corresponding specification drill.
• Align the mount with the hole, and put the expansion screw through the hanging
plate into the hole to fix it.
• Use special screws to connect the base with the DMU device.
•
• After connecting the power supply and the network, carry out debugging.
CAUTION

HYX-DMU-W/4G User Manual
11
Put the DMU on the table
• Use special screws to connect the base fixture with the DMU device and place it
vertically on the table.
• After connecting the power supply and the network, carry out debugging.

HYX-DMU-W/4G User Manual
3. Human-Computer Interaction
Method 1
Download and install the App through the following application stores:
•
• Google App market (Android, users other than mainland China ones).
Method 2
information:
APP".
Debugging APP".
3. Human-Computer Interaction

HYX-DMU-W/4G User Manual
13
4. Appendix
4. Appendix
Product Model HYX-DMU-W HYX-DMU-4G
Communication to Microinverter
Monitoring data limit from solar panels 400 400
Communication to Hyxi Cloud
Ethernet RJ45×1, 100Mbps RJ45×1, 100Mbps
Wireless
Default: 5 mins (1-15 mins Configurable)
Power Supply (Adapter)
Type External adapter
Adapter output voltage/current
Power consumption
General Data
Operating Ambient Temperature
Weight
Cooling Natural Cooling
Enclosure Rating
Installation method Desktop mounting / Wall mounting

HYX-DMU-W/4G User Manual
14
LTE
B1
B3
B40
WCDMA
B1
<15dBm
<15dBm

HYX-DMU-W/4G User Manual
15
Contact Information
providing the following information.
•
•
•
•
4. Appendix

The manual is subject to change without notice while the product is being improved.
support@hyxipower.com www.hyxipower.com

IC Warning
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement
* RF warning for Mobile device:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Avertissements RF pour appareils mobiles:
L'appareil est conforme aux limites d'exposition au rayonnement IC spécifiées pour les
environnements non contrôlés. La distance entre le radiateur et le corps doit être d'au moins 20
cm lors de l'installation et du fonctionnement de l'appareil.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
This manual suits for next models
1
Table of contents
Popular Storage manuals by other brands

LA Darling
LA Darling 35400900C215 Assembly instructions

LaCie
LaCie rugged XL user manual

Ednet
Ednet 31519 manual

Western Digital
Western Digital WD10000H1NC - World Edition Quick install guide

Addonics Technologies
Addonics Technologies AD25MSD user guide

Compaq
Compaq StorageWorks TM RAID Array 3000 Pedestal Storage... Hardware user's guide