i-MO CIRCOR OptiLine ACE4 Installation instructions

Original Operating Manual
Before commencing any work, read this instruction carefully! Failure to comply with
these instructions may cause damage and personal injury!
!
Screw pumps
OptiLine ACE4
Contents Page
Introduction 2
Safety 2
Installation 5
Start-up 8
Trouble shooting 9
Maintenance and Service 12
Service intervals 13
List of components 14
Exploded view/Ordering code 15
Dismantling and reassembling the pump 16
Dismantling 17
Reassembly 22
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
2
ATTENTION
ATTENTION
Safety
The manufacturer accepts no liability for damages caused by disregarding any of the documentation.
Intended use
• Only use the pump to pump the agreed pumped liquids (→ order data sheet).
• Adhere to the operating limits.
• Avoid dry running:
– Make sure the pump is only operated with, and never without, pumped liquid.
• Avoid cavitation:
– Open the pressure-side tting completely.
• Avoid damage to the motor:
– Do not switch on themotor more that themaximumpermissible number of times per hour (→ manufac-
turer’s specications).
• Consult the manufacturer about any other use of the pump.
• Pumps delivered without a motor must be assembled into a pump unit according to the provisions of
EC Machine Directive 2006/42/EC.
Prevention of obvious misuse (examples)
• Note the operating limits of the pump with regard to temperature, pressure, viscosity, ow rate and motor
speed (→ order data sheet).
• When using auxiliary systems, ensure there is a continuous supply of the appropriate operating medium.
• Do not operate the pump while the pressure-side tting is closed.
• Only select the setup type according to this operating manual. For example, the following are not allowed:
– Hanging pumps in the pipe
– Overhead installation
– Installation in the immediate vicinity of extreme heat or cold sources
General safety instructions
Observe the following regulations before carrying out any work.
Product safety
The pump has been constructed according to the latest technology and recognized technical safety rules.
Nevertheless, operation of the pump can still put the life and health of the user or third parties at risk or dam-
age the pump or other property.
• Only operate the pump if it is in perfect technical condition and only use it as intended, remaining aware of
safety and risks, and adhere to the instructions in this manual.
• Keep this manual and all other applicable documents complete, legible and accessible to personnel at all
times.
Document Purpose
ATEX additional instructions Operation in explosion-hazard areas
Order data sheet Technical specications, conditions of operation
Technical description Technical specications, operating limits
Supplier documentation Technical documentation for parts supplied by
subcontractors, e.g. drive system, coupling or
auxiliary operating system.
Spare parts list Ordering spare parts
Declaration of conformity Conformity with standards,
Content of the declaration of conformity
Other applicable documents
Introduction

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 3
• Refrain from any procedures and actions that would pose a risk to personnel or third parties.
• In the event of any safety-relevant malfunctions, shut down the pump immediately and have the malfunc-
tion corrected by the personnel responsible.
• In addition to the entire documentation for the product, comply with statutory or other safety and acci-
dent-prevention regulations and the applicable standards and guidelines in the country where the system is
operated.
Obligations of the operating company
Safety-conscious operation
• Ensure that the following safety aspects are observed and monitored:
– Intended use
– Statutory or other safety and accident-prevention regulations
– Safety regulations governing the handling of hazardous substances
– Applicable standards and guidelines in the country where the pump is operated
• Make personal protective equipment available.
Qualied personnel
• Make sure all personnel tasked with work on the pump have read and understood this manual and all other
applicable documents, especially the safety, maintenance and repair information, before they start any work.
• Organize responsibilities, areas of competence and the supervision of personnel.
• Ensure that all work is carried out by specialist technicians only:
– Fitting, repair and maintenance work
– Work on the electrical system
• Make sure that trainee personnel only work on the pump under the supervision of specialist technicians.
• Persons who have an implanted pacemaker:
– Must stay away from the pump with magnetic coupling and parts of the magnetic coupling
– May not work on or with any of the magnetic parts
Safety equipment
• Provide the following safety equipment and verify its functionality:
– For hot, cold and moving parts: on-site safety guards for the pump
– For possible electrostatic charges: provide the necessary grounding
– If there is no pressure relief valve in the pump: Provide an appropriate safety valve on the pressure
side between the pump and the rst shut-off device
Warranty
• Obtain the manufacturer’s approval prior to carrying out any modications, repairs or alterations during the
warranty period.
• Only use genuine parts or parts that have been approved by the manufacturer.
Drive system
For pumps delivered without a drive system, comply with the following requirements for the drive system:
• When using three-phase asynchronous motors, observe IEC 60034-30-1.
• Power of the drive according to EN ISO 5199 is recommended (EN ISO 5199 also applicable for drives of
screw pumps).
• Use coupling guard with the following requirements:
– Fastening elements must be connected to the pump unit in undetachable design (cannot get lost).
– Safety distances against the reaching of hazardous areas according to EN ISO 13857 must be
complied with.
Obligations of the operating company
• All directions given on the pump must be followed (and kept legible), e.g. the arrow indicating the sense of
rotation and the markings for uid connections.
• Pump, coupling guard and components:
– Do not step on them or use as a climbing aid
– Do not use them to support boards, ramps or beams
– Do not use them as a xing point for winches or supports
– Do not use them for storing paper or similar materials
– Do not use hot pump or motor components as a heating point
– Do not de-ice using gas burners or similar tools
• Do not remove the safety guards for hot, cold or moving parts during operation.
• Use personal protective equipment whenever necessary.
• Only carry out work on the pump while it is not running.
• Isolate the motor from its supply voltage and secure it against being switched back on again when carrying
out any tting or maintenance work.
• Reinstall the safety equipment on the pump as required by regulations after any work on the pump.
• With an implanted pacemaker:
– Stay at least 1 meter away from the pump with magnetic coupling or parts of the magnetic coupling.
– Do not work with or on the magnetic parts.

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
4
Magnetic eld
The magnetic eld of the magnetic coupling can destroy products that are sensitive to magnets.
These include:
• Pacemakers
• Plastic identity cards with magnetic strips
• Credit and check cards
• Electric, electronic and precision mechanical devices (such as mechanical and digital clocks, pocket
calculators, hard disks)
Specic hazards
Explosion-hazard area
• (→ ATEX additional instructions).
Hazardous pumped liquids
• Observe the safety regulations for handling hazardous substances (e.g. hot, ammable, poisonous or po-
tentially harmful) when handling hazardous pumped liquids.
• Use personal protective equipment when carrying out any work on the pump.
• Noise level:
– Check individual pump series noise level in respective Product Description

max. 90°
min. 60°
Fig 2. Lifting the pump
For pumps in explosion-hazard areas
(→ ATEX additional instructions).
Design limitations and technical data for each pump
are found in the Product description. Installation of IMO
AB low pressure pumps does not require special skills.
However, these instructions presume that the work is
carried out by experienced tters!
13 Failure to comply with these instructions
may cause damage and personal injury
Transport and storage
Always protect the pump against ingress of water
and other impurities. Store the pump in a clean, dry
and warm environment. The pump is delivered with
the internals oiled and with protective covers over the
pipe connections and drain openings. These covers
should remain in place for as long as possible during
the mounting and installation procedure but must be
removed before start up.
Lifting of pump
Lifting of the complete pump unit with the lifting device
attached to the motor, should be avoided as the motor’s
lifting provisions may not be able to carry the combined
weight of the pump and motor.
14 All pumps should be lifted with straps
securely attached to the pump or pump
unit, so that the center of gravity is located
between the straps in order to avoid
tipping of the pump.
Strainer
The pump has to be protected from foreign matters
such as weld slag, pipe scale, etc., that could enter the
pump via the suction line. If the cleanliness of the sys-
tem cannot be guaranteed, a strainer must be installed
in the inlet pipe near the pump. For practical reasons
a suction strainer with 0.8-2.0 mm mesh openings is
recommended.
The size of the strainer should be selected so that it is
large enough to allow adequate pressure at the pump
inlet. The pressure drop across the strainer should
preferably not exceed 0.1 bar at max. ow rate and nor-
mal operating viscosity. A vacuum gauge between the
strainer and the pump inlet is recommended to indicate
when the strainer needs cleaning.
15 All work carried out on the pump has to be
performed in such a manner that risks for
personal injury are observed.
16 Lifting a complete pump unit, using
slings or hooks attached to the pump or
connecting frame may be dangerous since
the centre of gravity of the pump unit may
be higher than the points of attachement.
Fig. 3 Strainer
Installation
Fig 1. Keep dry and clean
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 5

Fig. 6 Deaeration
Pipe connections
The pipe work shall be installed and supported so that
no pipe stresses are transferred to the pump body.
The pipe forces and torque transferred to the pump
shall be in accordance with ISO 14847. The pipe work
should be tight in order to avoid leakage and inltration
of foreign particles and/or air. Shut off valves should be
installed in both suction and discharge pipes, so that
the pump can be hydraulically isolated.
Suction line
The suction pipe should be designed so that the total
pressure drop, measured at the pump inlet ange, does
not exceed the suction capability of the pump. Make a
proper calculation of the suction line including compo-
nents such as valves, strainer, pipe bends etc. Gener-
ally, the pressure drop in the suction line should be as
low as possible, which is achieved if the suction pipe is
short, straight and has a suitable diameter. The velocity
in the suction line should be kept in the range
0.5 - 1.2 m/s. For L.O. circulating systems, we recom-
mend to keep it as low as possible. The suction line
must be equipped with a port that allows lling the
pump before start.
Discharge line
The discharge line should be dimensioned to keep the
velocity in the range 1 - 3 m/s.
Deaeration
In installations with negative suction head, where the
pump might be started against a pressurized system, a
deaeration pipe with an orice (2-3 mm is recommend-
ed) has to be installed. The deaeration pipe should be
connected to the outlet pipe’s highest point. This must
also be installed when the pump is used as a stand-by
pump.
Liquid trap
In some mounting arrangements the pump may not
retain the liquid at stand still. In such installations the
suction pipe should be arranged so it forms a liquid trap
together with the pump, keeping the pump half lled
with liquid.
Fig. 4 Pipe connections
Fig. 5 Suction Line
17 When handling liquids that may harm skin
use gloves and/or protective clothing
18 When handling liquids shich may involve
re hazards appropriate precautions to
avoid danger are to be taken.
Fig. 7 Liquid trap
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
6

bar
Gauges
Gauges for monitoring the pump’s working conditions
are recommended. These gauges should be placed
readable as close to the pumps in- and outlet anges
as possible. On the ACE Optiline standard pumps there
are gauge connections for both in- and outlet.
Pressure relief valve
All systems with screw pumps must be equipped with
a pressure relief valve installed immediately adjacent
to the pump. In the standard versions of IMO ACE
Optiline pumps, this pressure relief valve is an integral
part of the pump to protect the system against excess
pressure. When liquid is circulated through the valve it
heats up in proportion to the set pressure level and the
percentage of by-passed liquid. 100% bypass can only
be tolerated for less than about 3 minutes, 50 %by-pass
generally for unlimited periods of time. If more than
50% recirculation is anticipated, a value specic to each
application should be determined by closely monitoring
the pump body temperature. If the pump is operating in
line with a separate pressure control valve (see g.9),
the setting of the relief valve should be high enough
so as not to interfere with the control valve. Likewise, if
two pumps are operating in parallel, the setting should
be such that interference between the two valves is
avoided.
Also remember that a total bypass by the pumps
internal relief valve for longer periods will cut of the
cooling ow to the pumps magnetic coupling and
cause an overheating with destroyed magnets as a
result quite fast.
19 Oil leakage may make the oor slippery
and couse personal injury.
Fig. 8 Gauges
Fig. 9 Pressure Relief Valve
Fig. 10 External control with presssure relief valve
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 7

For pumps in explosion-hazard areas
(→ ATEX additional instructions).
Pressure testing and ushing
The system must be ushed and pressure tested before
connecting the pump. If corrosive liquid, such as water
is used, the system must be thoroughly drained, dried
and protected against corrosion after having been
ushed.
Before starting:
After installation and whenever it can be assumed that
the pump has been emptied, the pump must be thor-
oughly lled with liquid. See g 11.
20 Make sure the prime mover is locked out
and can not be started accidentally.
Direction of rotation
When the pump is ready to be started, switch the motor
briey on and off and check that the drive motor rotates
in the correct direction as indicated by the rotation ar-
row. The arrow is placed on the side of the front cover
5010 as well as on riveted steel plates on the connect-
ing frame 003.
Differential pressure
Differential pressures bellow 1 bar is strictly forbidden
as the magnetic coupling under these conditions may
loose its cooling ow and cause an overheating of the
magnetic coupling with a risk of a potential re as a
result.
We do strongly recommend magnetic coupled pumps to
be equipped with a differential pressure monitoring de-
vice that stops the pump automatically if the differential
pressure for some reason should drop to below 1bar.
Air in the pumped uid
It is forbidden to use the ACE Optiline pump with uids
that contains more than 0,2% of air due to the risk of
ignition during an eventual overheating of the pump.
Fig. 11 Filling the pump
Fig. 12 Direction of rotation
Fig. 13 Differential Pressure
21 Don't mix up with arrow for inlet and
outlet!
Startup
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
8

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 9
Problem Cause What to do
Wrong direction of rota-
tion
- Electric cables to motor wrongly
connected.
Reverse the terminal connection on
electric motor.
22 Connecting and disconnec-
ting of electric cables must
be done only by personnel
authorized to do such
work.
The pump cannot be
primed
- Wrong direction of rotation.
- Suction line is not open or pressure
drop in the suction line is too high.
- Major air leakage into the suction
line.
- The pump cannot evacuate the air
through the discharge line due to
excessive counter pressure.
See above.
Check all components in suction line
The inlet condition should be checked
with a vacuum gauge at the pump inlet.
Check the suction line.
See the chapter on Deaeration
(see page 19).
The magnetic coupling is
slipping
- A too high viscosity has caused the
magnetic coupling to slip.
- The pump is blocked inside the ro-
tors by a foreign object.
Lower the viscosity to a maximum
approved (the viscosity normally used
in the pumped liquid) and restart the
pump by switching it off and on.
Remove the foreign object from the
pump and control the bores and rotors
for abnormalities/damages. Restart the
pump by switching it off and on.
No ow - The pump is not primed.
- The pressure relief valve is set be-
low the counter pressure.
See above.
Readjust the pressure relief valve to a
value above counter pressure.
Flow too low - The magnetic coupling is slipping
- The pressure relief valve is set too
low (Discharge pressure also low).
- Something is restricting the ow in
the suction line. (This would usually
cause noise).
- The pumped liquid contains a
signicant amount of compressible
gas, such as free air. (This would
usually cause noise).
See above.
Readjust the pressure relief valve
Check all components in the suction
line (strainers, valves etc.).
Go thru the system and determine if
there are any leaks.
Trouble shooting

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
10
Problem Cause What to do
Pressure too low - The pressure relief valve is set too
low.
- Counter pressure in the discharge
line is too low due to a major leak-
age.
- The valve piston is stuck in open
position.
- Something is restricting the ow in
the suction line. (This would usually
cause noise).
- The pumped liquid contains a
signicant amount of compressible
gas, such as free air. (This would
usually cause noise).
- A too small pump has been chosen.
Readjust the pressure relief valve.
Check the components in the discharge
line inclusive the recipients.
Check the valve. See Maintenance and
Service instruction for this pump.
Check all components in the suction
line (strainers, valves etc.).
Contact your IMO AB representative.
Pressure too high - The pressure relief valve is set too
high.
- The oil is too cold (or has higher
viscosity than anticipated).
- Counter pressure in the discharge
line is too high.
Readjust the pressure relief valve.
Reduce the pressure setting until oper-
ational temperature has been reached.
Check the discharge line.
Drive motor difcult to
start or tends to stop by
tripping the motor over-
load relay
- Counter pressure too high.
- Liquid too cold.
- Motor is undersized for the prevail-
ing conditions.
- Electrical power supply faulty.
- Motor overload relay set too low or
is faulty.
- Incorrect setting of Y/D starter.
See above: Pressure too high.
Readjust the pressure relief valve to a
lower value. Thus the power consump-
tion for the pumping is relieved and
overloading due to the high viscosity
may be avoided. When the liquid has
reached normal temperature and thus
ows easily, the relief valve is reset to
normal pressure.
Check the motor.
Check the motor and motor connection.
Readjust or replace the relay.
Readjust the setting of the starting
sequence. The time before the motor
overload relay is tripped should not
exceed 10-15 seconds.
Noise and vibration
23 Monitor the
pump function
and shut down
if any sign of
malfunction is
noticed
- The ow to the pump is insufcient.
- Insufcient support of pipe work.
- Air leakage into the suction line.
- Faulty electrical supply.
See chapter: The ow is too low.
Check for pipe vibrations in the pump
connections. Check that the pipes are
sufciently clamped.
Check the suction line for air leakage.
Check all three phases of the supply.

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 11

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
12
Indentication of safety instructions
Non complience of safety instruc-
tions identied by the following
symbol could affect safety for
persons
Safety instructions where
electrical safety is invol-
ved are identied by:
Safety instructions which shall be considered
for reasons of safe operation of the pump
or pump unit and/or protection of the
pump or pump unit itself are marked
by the sign:
Introduction
A screw pump from IMO is a quality product that is designed for a long problem free operation in tough environ-
ments. As all other mechanical products they do however requires a certain grade of maintenance and service in
order to guarantee a faultless and economic favourable operation.
A recommendation is to go through the pump each 5 year in order to replace wear details such as ball bearings and
certain gaskets and o-rings. A relatively small review of a screw pump from IMO means that the pump in most of
the cases will be in a condition “as new” and therefore give the operator another long and problem free operation.
Maintenance and Service
For pumps in explosion-hazard areas (→ ATEX additional instructions).

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 13
Service intervals
The intervals for inspection and replacement of wear
parts vary greatly with the properties of the pumped
liquid and can only be determined by experience. All
internal parts of the ACG Optiline pump are lubricated
by the pumped liquid. Pumping liquid which contain
abrasive materials, or liquid that is corrosive, will sig-
nicantly reduce service life and call for shorter service
intervals. Wear in the pump will normally show as:
• Vibration
• Noise
• Loss of capacity
• Reduction in ow/pressure
• Loss of the magnetic power
We recommend planned inspections and/or overhaul
at regular intervals, not exceeding 5 years. It is recom-
mended to always have the spares included in joint
spare part kit G057 together with the ball bearing 122
available for a planned inspection.
Inspection of rotors
To reach the idler rotors in a quicker way than de-
scribed in the dismantling section, loosen the rear cover
(480) with the valve. Screw out the idler rotors back-
wards. Internal clearances in the pump, which are vital
for its proper function, may have been affected by wear.
Acceptable wear can be determined only by experience
of the actual application. As a rule of thumb the follow-
ing max clearance values may apply: Between rotor
and bores: 0.2 mm, Between rotor anks: 0.4 mm For
light duties (low pressure, medium viscosity) even big-
ger clearances may be acceptable but for low viscosity/
high pressure duties the limit will be lower. Also watch if
there are major scratches on these parts.
Inspection of the magnetic coupling
The magnetic coupling with all its components is con-
sidered to be maintenance free if operated and mount-
ed according to our instructions.
The lifetime of the magnets is well within the lifetime of
the pump and exchange of the magnets is only neces-
sary if a major breakdown has occurred as a result of
for example excessive amounts of dirt or particles in the
pumped uid.
Common aspects whit magnetic
couplings
Permanent magnetic couplings generate a strong
magnetic eld. The installation must be carried out only
by trained staff that has the understanding of how a
magnetic coupling acts and all the safety precautions
related to it. All installation instructions must be strictly
followed. Modications or changes to the magnetic cou-
pling or its components are not to be allowed under any
circumstances. IMO does NOT take any responsibili-
ties for damages caused by improper use or damages
related to this.
Magnetic data carriers such as bank cards, oppy disks
etc may become unreadable and should always be kept
separated from the magnetic eld.
DANGER
Installations and maintenance must always take place
during complete shutdown in an un-pressurised condi-
tion. The drive unit must be secured against inadvertent
switching on by means of blocking the electrical supply
to the electric motor in order to avoid serious injuries
due to rotating parts.
2 ATTENTION! In areas where permanent
magnetic couplings are handled or
stored with open access, persons with
heart pacemakers should keep a distance
of 3 meters. For permanent magnetic
couplings assembled within a pump a
safety distance of 3 meter is sufcient.
Precautions prior to starting
maintenance on the pump
3 If the pumps operating temperature
exceeds 60°C, let the pump cool off before
any service, maintenance or dismantling
work is commenced to avoid burn injury
4 All work carried out on the pump has to be
performed in such a manner that risks for
personal injury are observed!
5 When handling liquids that may harm skin,
use gloves and/or protecting clothing!
6 When handling liquids which may involve
re hazard appropriate precautions to
avoid danger are to be taken.
7 In case of failure for system with elevated
pressure, uid jets may cause injury and/
or damage.
8 Oil leakage may make the oor slippery
and cause personal injury.
9 Before any maintenance work, ensure that
the driver is deenergized and the pump
hydraulically isolated.
10 Connecting and disconnecting of
electrical cables must be done only by
personnel authorized to do such work.

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
14
List of components
Valid for all ACE Optiline Generation 4 pumps with sizes 025, 032, 038 and leads L, K, N & D
With version codes, NJBP, NKBP, NLBP & NMBP
PosNo Designation Qty G012 G054 G057 G070 G098 Notes
002 Motor 1
003 Connecting frame 1
004 Angle bracket 1
005 Magnetic coupling complete 1 X
005A Retaining ring 1 X X X
005B Sealing can 1 X
005C Inner magnetic rotor 1 X
005D Outer magnetic rotor 1 X
006A Screw 4
007A Screw 6
007B O-ring 1 X X X
1020 Power rotor 1 X X
112 Balancing piston 1 X X 2
113 Shaft key 1 X X
122 Ball bearing 1 X X
124 Retaining ring 1 X X X
124A Support ring 1 X X X
202 Idler rotor 2 X X
351 Balancing bush 1 X X
401 Pump body 1
418 Gasket 1 X X 1
423 Gasket 1 X X 1
451 Screw 4
453 Screw 4
462 Plug 1
462A Sealing washer 1 X X
463 Plug 1
463A Washer 1 X X
5010 Front cover 1
502 Plug 2
506 Gasket 1 X X
551 Rear cover 1
556 Gasket 1 X X
6000 Compl. Valve 1 X
(605) O-ring 1 X X X
(608) Valve spindle 1 X 2
(608A) Tension pin 1 X 2
6120 Set screw 1 X 2
(613) Tension pin 1 X 2
(614) Valve piston 1 X 2
(615) Valve spring 1 X 2
701 Screw 4
701A Washer 4
702 Screw 4
702A Washer 4
703 Screw 3
703A Washer 3
998 Drive hub 1
998B Screw 1
Explanations
G012: Rotorset
G054: Major kit
G057: Joint kit
G070: Complete valve
G098: Complete
magnetic coupling
Notes:
1) Gaskets for counter
anges
2) Not sold separately

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 15
11 Before commencing any work, read this instrucion carefully! Failure to comply with these instrutions
may cause damage and personal injury!
For more information about the pumps identication code, technical data and performance we refer to the ACE
Product description.
Recommended Spare Parts Kits
and tool kits
Every shutdown for service of a plant is costly.
The time for repair should therefore be limited to
a minimum which can be accomplished by keep-
ing a spare pump. The changed pump can later be
repaired at a suitable place and can then be used as
a spare pump. For maintenance the following spare
parts kits and tools are recommended:
Ordering Code
Part numbers for pump
size
Item Spare part sets 025 032 038
G012 Rotor set D-lead 193362
" K-lead 193360
" L-lead 193356 193358
" N-lead 193357 193359 193361
G054 Major kit D-lead 193369
" K-lead 193367
" L-lead 193363 193365
" N-lead 193364 193366 193368
G057 Joint kit 193374 193375 193376
G070 Valve element 189873 189873 189873
G098 Magnetic
coupling
xKxx 193370 193370
" xLxx 193371 193371 193371
" xMxx 193372 193372
" xNxx 193373
122 Ball bearing 173765 173765 173591
Kit: Content: To be used for:
G057 Gaskets & o-rings Dismantling of pump
G012 Rotor set Repair after break
down
122 Ball bearing Repair after break
down
193397 Toolkit Dismantling & as-
sembly
Exploded View

702A
998B 998 006A 113003 401
462A
462
502
(6120)
(605)
6000
(613)
(608A)
(608) (615)
(614)
514
005
007A
007B 351 556
2021020122
124
124A
005A
506
5010
551(112)
703B
703A
703
002
004
453
463
463A
440
771
771A
A - A
1:1
702
B
CC
DD
E - E
1:1
D - D
C - C
A
B - B
A
B
OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
16
List of tools necessary for dismantling and reassembly
A = Puller
B = Spanner 16 mm
C = Plastic mallet
D = Allen keys (3 mm & 5 mm)
E = Mounting Sleeve, D = 25,5 mm
F = Screw driver
G = Plier
H = Guide Pins
J = Oil can
Sectional View
Dismantling and reassembling the
pump
Tightening torque (Nm)
Pos No Torque
0006A
0007A
9
5
451 40
453 40
462 40
463 40
701 40
702 IEC
80-90
100-132
25
40
703B IEC
80-90
100-132
25
40
998B IEC
80
90
100-132
9
20
40
-
Loctite 222

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 17
Dismantling
A.
• Turn the electricity OFF.
• Close the valves.
12 Use appropriate vessels to collect oil
spillage when removing and opening
the pump
B.
• Loosen the screws 701 with an allen key.
C.
• Mount the guiding pins into the connecting
frame.
D.
• Pull out the pump from the connecting frame
together with the magnetic coupling. Beware
of the magnetic force!

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
18
E.
• Loosen the screws 007A with a allen key
• Pull out the sealing can 005B
• Remove the o-ring 007B
F.
• Remove the circlip 005A with a suitable plier.
G.
• Remove the inner magnetic rotor by means of a
suitable puller.
H.
• Remove the key 113 with a suitable tool.
I.
• Unscrew the bolts 451 with an allen key.
• Remove the front cover 5010 with its gasket
506.

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se 19
J.
• Pull out the main rotor 1020 from the pump
body with hand force.
M.
• Pull out the idlers 202 from the pump body.
K.
• Remove the circlip 124 with a suitable plier
from the main rotor 1020.
• Remove the support washer 124A from the
main rotor 1020.
L.
• Remove the ball bearing 122 from the main
rotor 1020 with a suitable puller

OACE4 2019.12 en-GB, ID-Nr.: 163-039/B
www.imo.se
20
N.
• Release the spring tension from the relief valve
by unscrewing it counter clockwise.
• Count the number of turns so it easily can be
set to the correct value again.
O.
• Remove the bolts 453 and the back cover 551
with its gasket 556 together with the valve
6000.
P.
• Remove the valve 6000 with its o-ring 605.
Q.
• Remove the bolts 702 and pull out the motor
from the connecting frame.
Table of contents
Other i-MO Water Pump manuals

i-MO
i-MO ACF5 Manual

i-MO
i-MO CIRCOR D12DZ-250 User manual

i-MO
i-MO CIRCOR GLH8L-400 Series User manual

i-MO
i-MO OptiLine LPE4 Installation instructions

i-MO
i-MO ACF5 Installation instructions

i-MO
i-MO *G3D-250 User manual

i-MO
i-MO CIRCOR BK6DHZ(C)-250 User manual

i-MO
i-MO ACG Manual

i-MO
i-MO D4 Manual

i-MO
i-MO ACE3 Series User manual
Popular Water Pump manuals by other brands

STO
STO M-8 Operation and maintenance instructions

Lincoln
Lincoln B Series Service & operating manual

ARO
ARO ARO 662605 Operator's manual

Patterson
Patterson HSC Operation and maintenance

Graf
Graf 356010 Operation and assembly instructions

Grundfos
Grundfos PACOpaQ Installation and operating instruction manual