iB KOJAK User manual

USER MANUAL

2
CONTENTS
Welcome 3
Unpacking 4
Connecting 5
Cleaning 6
Resources 7
Support/Software Development
SDK Download Link
Scanning 8
Finger Conditions
Hand Orientation 9
Correct Placement - Top View
Finger Contact 10
Correct Placement - Side View
Flat Scanning 11
Finger Placement
Thumb Capture
Roll Scanning 13
Finger Placement
Rolling Examples
One-Finger Scanners 1 5
Columbo
Curve
Two-Finger Scanners 16
Sherlock
Watson Mini
Kojak Dimensions 17
Specifications 18
Compliance 19
© 2018 Integrated Biometrics, Inc. All rights reserved.

3
WELCOME!
Thank you for purchasing Kojak, Integrated Biometrics’
newest addition to our patented Light Emitting Sensor (LES)
fingerprint scanning solutions. Kojak is the most durable, highest
performance FAP 60 FBI Appendix F-certified ten-print live
scanning solution.
Please read this manual thoroughly before using your Kojak
to review proper steps for unit operation and capture processes.
Your Integrated Biometrics reseller and the IB team are ready to
answer any questions you may have!

4
Pull UP and BACK to remove protective cover.
UNPACKING
CONTENTS
Kojak is provided in a securely packaged case. Please notify your
Integrated Biometrics reseller in the event of damage during shipment.
The product packaging contains all Kojak hardware components.
The latest Software Development Kit (SDK) may be downloaded from
Integrated Biometrics. Consult page 6 of this manual for details about the
software download.
REMOVE COVER
ROLL
CAPTURE CAPTURE CAPTURE
1 - Kojak FBI Certified Appendix F FAP 60 Scanner
with Integrated 1.4-meter Cable with USB-A Connector
1 - Removable
Platen Cover
ROLL
CAPTURE CAPTURE CAPTURE
Bezel
Guides for
Finger Placement
and Boundaries
Platen

5
CONNECTING
CONNECT USB TO DEVICE
Connecting Kojak is easy!
1. Download and install the latest IBScanUltimate SDK
2. Connect Kojak to the system via USB (USB 2.0 or later)
Note: An adapter may be required and is not provided
3. Integrated Biometrics provides a variety of test applications
for demonstration. IBScanUltimate SDK includes demonstration
applications for supported platforms and source code for ease
of deployment.
OTG Adapter
(not included)
USB A
Kojak Cable
Mobile
Android Device

6
CLEANING
BEST PRACTICES
Cleaning the Kojak scanner is a simple process.
· Kojak should be cleaned approximately every 1000 scans
or as needed.
· Use IB Cleaning Kit part number IBHCK-01.
· Wipe clean using microfiber cloth (included with cleaning kit).
WARNINGS AND CONSIDERATIONS
· Alcohol and alcohol-based cleaning solutions may stain
if allowed to remain on the platen.
· Wipe alcohol products from Kojak’s platen and clean
using a water-based solution.
· Care should be taken to clean and remove chemicals
immediately following a spill.
· Remove chemical solutions immediately using a water-moistened rag.
· Common chemicals that require immediate attention include:
- Acetone and polish removers
- Paint
- Paint thinners
- Stain removers
- Gasoline or petroleum products
- Pesticides and herbicides
- DEET or DEET infused products
- Cleaning cloths, rags, or devices impregnated
with any of the above examples

7
RESOURCES
SUPPORT / SOFTWARE DEVELOPMENT
The IBScanUltimate Software Development Kit (SDK) is a set of robust
tools that empower solution providers with the ability to deploy compel-
ling LES biometric acquisition applications. The SDK includes support
for a variety of operating systems and exceeds the needs of the most
challenging environments.
The SDK includes Application Programming Interface (API) documenta-
tion, IB software components, demonstration applications and source
code for each platform. Demonstration source code is a simple reference
for integrators to rapidly develop solutions using Integrated Biometrics’
LES technologies. We encourage you to review the included materials
and explore the limits of creativity when designing custom biometric
solutions.
If you have any questions, please contact your Integrated Biometrics
reseller or the IB team. We’ll be glad to provide assistance during
solution development.
DOWNLOAD SDK
www.integratedbiometrics.com/sdk-downloads
Download Software Development Kit (SDK)
Technical Documentation and Product Support

8
SCANNING
FINGER CONDITIONS
VERY MOIST FINGERS
· Result: Images too dark, poorly defined. Indicates too much moisture
on the fingers.
· Solution: Dry the fingers with a towel or cloth before
fingerprint capture.
· The resultant images will be lighter and the NFIQ quality scores
will improve.
VERY DRY FINGERS
· Result: Images take several seconds to appear or contrast appears
lighter than desired.
· Solution: Rub a small amount of moisturizer on the fingertips.
(Do not slather.)
· The resultant images will be darker and the NFIQ quality scores
will improve.
· Gentle or light contact with the plate is recommended in scanning.
Placing extra pressure on the hand is not recommended.
· Avoid using hand sanitizers, alcohol based lotions, and baby wipes
prior to scanning.
BEST PRACTICES
· Never put a wet hand on the scanner i.e., just washed and not
thoroughly dried, holding a bottle of liquid that leaves condensation
on your hand. Hands should be wiped dry.
· Never use two hands on the scanner at the same time
(see image on next page).
Dry FingerprintsNormal Fingerprints Wet Fingerprints

9
HAND ORIENTATION
CORRECT PLACEMENT - TOP VIEW
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Grounding
Bar
Fingers should be pointing at cord and
grounded firmly against the platen and
grounding bar.
Platen
ROLL
CAPTURE CAPTURE CAPTURE
Never use two hands on the
scanner at the same time.

10
FINGER CONTACT
CORRECT PLACEMENT - SIDE VIEW
Platen
Grounding
Bar
Fingers should be pointing at cord
and grounded firmly against the platen
and grounding bar. Gentle or light
contact with the plate is recommended
in scanning. Placing extra pressure on
the hand is not recommended.

11
FLAT SCANNING
FINGER PLACEMENT
Place hand firmly against the bezel to ensure proper contact.
· Kojak LEDs glow orange
· Place right hand firmly against the bezel
to ensure proper contact
· Kojak LEDs glow green when capture is complete
· Repeat process for left hand
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Ready to Scan - Left Scan Complete - Left
Ready to Scan - Right Scan Complete - Right
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Orange
LEDs
Green
LEDs
Bezel
Bezel
Platen
Platen

12
THUMB CAPTURE
Place bottom of thumbs firmly against the bezel to ensure proper contact.
· Kojak LEDs glow orange
· Grasp the unit with index fingers pointed towards
the LED notification panel at the top of Kojak
· Place thumbs flat against the platen
· Kojak LEDs glow green when capture is complete
FLAT SCANNING
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Ready to Scan Thumbs Thumb Scan Complete
Align thumbs with
guide markers
Bezel
Platen

13
ROLL SCANNING
FINGER PLACEMENT
When performing rolls, place indicated finger firmly against the bezel and
platen to ensure proper contact.
· Roll scan LED illuminates
· Individual LEDs indicate specific finger to scan
· Place finger flat on platen between bezel guide markers
extending slightly past the first knuckle
· While maintaining good contact with both platen and bezel,
roll finger 45 degrees to the left
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Roll Left Complete
NOTE: Optimal scanning
requires stopping at +/-
45 degrees from flat.
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Finger PlacementReady to Scan - First Finger
Individual
LEDs
Bezel
Platen

14
ROLL SCANNING
· While maintaining good contact with both platen and bezel,
roll finger 45 degrees to the right
· On-screen operator visualization and LED / audio notification
from Kojak notify scan complete
· Kojak finger placement LED indicates the next finger in sequence
ROLLING EXAMPLES
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
ROLL
CAPTURE CAPTURE CAPTURE
Ready to Scan Next Finger
Proper PrintImproperly Rolled
Missing
Area
Over Rolled
Smear and
Distortion
Bezel
Platen

15
ONE-FINGER SCANNERS
COLUMBO
Columbo (embedded version) and Columbo Desktop (pictured) are the
world’s smallest and lightest FBI PIV-certified FAP 30 single-fingerprint
scanners. The incredibly accurate scanners provide a new alternative
for unattended verification applications.
CURVE
Curve (pictured) and eCurve (embedded version) succeed in demanding
real-world conditions common to commercial applications. Curve scanners
are globally-deployed as an accurate, cost-eective solution for biometric
identification.
69.8 mm / 2.74”
30 mm / 1.18”
6
6
mm
/
2
.
60
”
75 mm / 2.95”
48 mm / 1.89”

16
TWO-FINGER SCANNERS
SHERLOCK
Sherlock is the world’s smallest, lightest FBI Appendix F-certified, FAP 45
fingerprint scanner for embedded applications. Sherlock is ideal for hand-
held devices requiring flat-print and single finger roll scans.
WATSON MINI
Watson Mini is an FBI Appendix F-certified, FAP 45 fingerprint scanner
for both embedded and standalone applications. It supports flat print
and single finger roll scans and can be a cost eective platform for
ten-print enrollments.
62 mm
/
2
.
4
4”
60 mm / 2
.
36
”
33 mm / 1.30”
6
5
.2 mm /
2.5
7
”
61.6 mm
/
2.
4
3”
14.2 mm / .56”

17
KOJAK DIMENSIONS
114.7mm
131.8mm
82.6mm
131.8mm

18
SPECIFICATIONS
Kojak exceeds the needs for enrollment and verification applications in demand-
ing international programs. It is particularly suited for mobile applications where
minimal size, weight and power consumption have significant value. Kojak is the
cost-eective solution for ten-print live scanning requirements.
Kojak is provided with a full featured SDK to enable eective integration into
applications requiring certified FAP 60 quality images.
FBI Certification FBI Appendix F, PIV, FIPS 201, FAP 60
Resolution 500 PPI
Platen Size 3.5” (W) x 3.15” (H) / 88.9 mm (W) x 80.01 mm (H)
Sensing Area 3.2” (W) x 3.0” (H) / 81.28 mm (W) x 76.3 mm (H)
Gray Scale 256 grayscale dynamic range
Image Size 1600 (W) x 1500 (H) pixels
Supported Image Formats RAW, JPEG2000, BMP, PNG, WSQ
Scanner Physical Size 4.5” x 5.2” x 3.3”
114.3 mm x 132.08 mm x 83.83 mm
Interface USB 2.0
USB Certification Spec USB-IF USB.ORG
USB Level 4.40V – 5.25V
FCC/CE Conformance FCC Part 15 (per ANSI C63.4:2014) Class B
CSA ICES-003 Class B
CE Emissions: EN 55022:2010 Class B
CE Immunity EN 55024:2010/A1:2001/A2:2003
IEC 61000-4-2
Equipment Safety IEC 60950-1
Product Weight 725 grams / 1.6 lbs (not including cable)
Power Consumption <300mA during full scanning mode
Air Discharge/Contact Discharge In compliance with IEC 61000-4-2
Operating Temperature -10°C ~ +55°C / 14°F ~ 131°F
Humidity 30~85% RH < 40°C / 104°F (Non-condensing)
Storage Temperature -30°C ~ +60°C / -22°F ~ 140°F
RoHS Certified RoHS Directive 2002/95/EC
Ingress Protection Direct water spray, no dust or dirt ingress,
IP65 bezel to film
OS Support Windows Desktop 32/64 bit (7, 8, 10),
Windows Server, Linux, Android 4.0+, Java
Surface Durability MIL-C-675c 4.5010, MIL-STD-810F

19
COMPLIANCE
FCC
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and on,
the user is encouraged to try to correct the interference by one or more
of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by
Integrated Biometrics could void the user’s authority to operate this
equipment legally under FCC regulations.

20
Integrated Biometrics, Inc.
www.integratedbiometrics.com
WORLD-CLASS
TECHNOLOGY
LES technology empowers energy-ecient, compact, and durable
biometric scanning solutions unique to the market. Ready to deploy
in any environment under any conditions, Integrated Biometrics’
scanners are the choice for high performance applications.
Table of contents
Popular Scanner manuals by other brands

Planon
Planon DocuPen XSERIES user guide

Choose 2 rent
Choose 2 rent 7Qi quick start guide

Canon
Canon imageFORMULA DR-2080C Specifications

Epson
Epson GT-2500 Series Product information

Panasonic
Panasonic KV-S4065CL - Sf Clr Duplex 65PPM USB 2.0 Lgl 300PG... operating manual

Uniden
Uniden UBC69XLT owner's manual