The opto-coupler requires only 1mA input current to operate properly. The absolute maximum
rating is 0mA, so this value should never be exceeded, or the port will be damaged. The port will
be active with an external voltage of +5 to +24V applied.
3 . O u t p u t P o r t S t ru c t u r e
All the output ports in connectors IN/OUT 1 and 2 have the same hardware structure. They are
open collector, according to the simplified diagram.
Each port has a NPN darlington output, able to supply up to 500mA when conducting. The load
circuit has to supply its own voltage.
3 . 7 R F c o n n e c t i o n s
There are two 50 ohm RF connectors at the front of the unit for Transmission (TX) and Reception
(RX) antennas. The connectors are SMA, and have to be connected through low loss high
frequency cables to the corresponding RF connectors in the HF or UHF antennas.
The TX cable and connector are always marked RED, while the RX cable and connector are
marked GREEN for easy identification.
For best results, the antenna models HTP200, UTP200 and LTP100 have to be connected
directly to the RTS200 (not using cables), by means of SMA-SMA transitions (tubes) provided with
the antennas.
Pag: 9 Document: RTS200 Code: 001.0038 Version: 1
S
GND