Iberwave RTS200 User manual

RTS200
Hardware Manual
IBERWAVE

IBERWAVE
Iberwave Ingeniería SLL
C/ Ronda de Poniente 4-2ºG • Tres Cantos
287 0. MADRID
Teléfono (91) 80 0 0 • Fax (91) 80 0 0
Document Info
DOCUMENT NAME RTS200
DESCRIPTION RTS200 hardware description.
FILE NAME rts200 hardware manual.odt
CODE 001.0038
VERSION 1
STATUS Draft
CREATED BY JCPM DATE 17/01/08
APPROVED BY DATE
HISTORY Version 1.0 Original version
Pag: 2 Document: RTS200 Code: 001.0038 Version: 1

T a b l e o f C o n t e n t s
1 INTRODUCTION................................................................................................................................................ 4
2 MECHANICAL..................................................................................................................................................... 5
2.1 Front Connections......................................................................................................................................... 5
2.2 Rear Connections..........................................................................................................................................
3 INTERFACES..................................................................................................................................................... 7
3.1 RS232........................................................................................................................................................... 7
3.2 In/Out............................................................................................................................................................ 7
3.3 Vdc Power IN................................................................................................................................................ 8
3.4 Ethernet......................................................................................................................................................... 8
3.5 Input Port Structure....................................................................................................................................... 8
3. Output Port Structure..................................................................................................................................... 9
3.7 RF connections............................................................................................................................................. 9
4 ANTENNAS....................................................................................................................................................... 10
Pag: 3 Document: RTS200 Code: 001.0038 Version: 1

1 I n t r o d u c t i o n
The RTS200 combines a HF / UHF RFID reader and a powerful set of virtual instruments (RF
Generator, Spectrum analyser) to provide a complete RFID tester, suitable for both laboratory and
production line test of RFID passive tags.
Both UHF and HF frequency ranges are covered, and some of the most widely used protocols are
included in the basic package. The unit can be upgraded for other current or future protocols by
means of a simple firmware / software upgrade.
This document describes the RTS200 interfaces and connections.
Pag: 4 Document: RTS200 Code: 001.0038 Version: 1

2 M e c h a n i c a l
The hardware consists of an aluminium box with all the electronics inside, and connectors at the
front and at the rear of the unit. The external dimensions are shown below.
2 . 1 F r o n t C o n n e c t i o n s
There are two coaxial connectors at the front of the unit, for the Reception (Green) and
Transmission (Red) antenna sections.
Pag: 5 Document: RTS200 Code: 001.0038 Version: 1

2 . 2 R e a r C o n n e c t i o n s
The connectors at the rear are shown in the picture.
Connetor Explanation
RS232 RS232 Serial Port host interface
In/Out 1 Digital interface with the machine for production environments
USB USB host interface
Vdc ower In Power supply input
Ethernet 10 Base-T connector for ETHERNET based interface
Pag: Document: RTS200 Code: 001.0038 Version: 1

3 I n t e r f a c e s
This section describes:
•The connector pin assignment
•The I/O port structure
3 . 1 R S 2 3 2
This is a Miniature DIN, female way connector.
Pin Signal Notes
1 NC Not Connected
2 TXDAT RS232 Output from RTS200 to Host
3 RXDAT RS232 Input from Host to RTS200
4 NC
5 DGND GND reference
NC
3 . 2 I n / O u t
This is a Miniature DIN, female 8 way connector.
Pin Signal Notes
1 +12 Vdc Source for +12Vdc, current limited by a series 470 ohm resistor
2 DEM2 Digital modulation output. Outputs a digital pattern according to the selected
protocol
3 E2+ Anode of opto-coupled input number 2
4 E2- Catode of opto-coupled input number 2
5 S1 Open drain output number 1
Pag: 7 Document: RTS200 Code: 001.0038 Version: 1

Pin Signal Notes
S2 Open drain output number 2
7 S3 Open drain output number 3
8 GND Reference GND
The signals in this connector have some pre-assigned functions correspoding to the machine
interface in the online test operating mode. The functions are described in the following table.
Signal Function Notes
E2 Trigger Machine-> RTS200 signal to start the test. Configurable polarity
S1 Result Indicates TEST PASS or TEST FAIL conditions, according to
configuration
S2 EOT End of test signal. The RTS activates this signal after the test is
finished
S3 Delayed Result Same as result, delayed by a number of triggers
See the I/O port structure section for a description of the hardware interface, and the RTS200
User´s guide for the description of the operation and configuration of these signals.
3 . 3 V d c P o we r I N
This is a 5 way DIN circular connector (DIN41524-05).
Pin Signal Notes
1 DGND Reference GND
2 DGND Reference GND
3 +5V d.c. +5V
4 -12V d.c. -12V
5 +12V d.c.+12V
3 . 4 E t h e r n e t
This is a standard 10 Base T connector. A Standard Cat V STP cable should be used. To connect
the unit to a single computer, either a cross-over cable or a hub (or switch) shall be used.
3 . 5 I n p u t P o r t S t r u c t u r e
The Input port in connector IN/OUT is opto-coupled, and has the following structure from the
electrical point of view.
Pag: 8 Document: RTS200 Code: 001.0038 Version: 1
R=2K2
E+
E-

The opto-coupler requires only 1mA input current to operate properly. The absolute maximum
rating is 0mA, so this value should never be exceeded, or the port will be damaged. The port will
be active with an external voltage of +5 to +24V applied.
3 . O u t p u t P o r t S t ru c t u r e
All the output ports in connectors IN/OUT 1 and 2 have the same hardware structure. They are
open collector, according to the simplified diagram.
Each port has a NPN darlington output, able to supply up to 500mA when conducting. The load
circuit has to supply its own voltage.
3 . 7 R F c o n n e c t i o n s
There are two 50 ohm RF connectors at the front of the unit for Transmission (TX) and Reception
(RX) antennas. The connectors are SMA, and have to be connected through low loss high
frequency cables to the corresponding RF connectors in the HF or UHF antennas.
The TX cable and connector are always marked RED, while the RX cable and connector are
marked GREEN for easy identification.
For best results, the antenna models HTP200, UTP200 and LTP100 have to be connected
directly to the RTS200 (not using cables), by means of SMA-SMA transitions (tubes) provided with
the antennas.
Pag: 9 Document: RTS200 Code: 001.0038 Version: 1
S
GND

4 A n t e n n a s
The available antennas (standard) are shown in the chart below.
Model Name
UTP100 HTP100 HTP200 UTP200 LTP100
and
UHF HF HF UHF LF
Frequency
Range
700-1200MHz 3-40MHz 3-40MHz 700-1200MHz 80KHz-0.5MHz
Function
Functional test Functional
/electrical test
Functional /
Electrical test
Electrical /
Functional test
Electrical /
Functional test
Size of tags
ny ISO-C RD or
similar
Small (disc, glass) ny Small (disc, glass)
Calibrated
- Yes Yes Yes* Yes
Enclosure
No No Yes No Yes
Size
10x10cm 10x10cm 9x6cm 9x6cm 9x6cm
Application
Production line
(inlays, labels)
Production line
(inlays, labels),
laboratory
Production line
inspection,
laboratory
Production line
inspection,
laboratory
Production line
inspection,
laboratory
Pag: 10 Document: RTS200 Code: 001.0038 Version: 1
Table of contents