ICON ARS-1000 User manual

IMPORTANT -
READ THIS PAGE BEFORE YOU INSTALL THE ICON SYSTEM.
To maximize the benefits of the ICON system A.I.R. Corp. recommends
that the system be installed in the room that the primary beneficiary(s)
spends the greatest amount of time. The bedroom is the most common
choice.
A.I.R. Corp. recommends closing the door to the selected room to
help retain the fresh, sterile air delivered by the ICON. Even with
the door closed the fresh sterile air will permeate throughout the
home forcing contaminated air out.
Pre-Installation
To validate your warranty, register: on-line at www.air-us.com, by phone at
1.866.437.0044 or by mailing the warranty registration card to: American
Innovative Research Corp., 19 Abbot St., Andover, MA 01810.
You will need the ICON serial number when registering your product.
The serial number can be located on the packing slip located on the outside
of the shipping package.
Record the serial number on your registration card and have it available
when registering by phone or on-line.
40460265 Rev. 1

Clean Air Delivery System
American Innovative Research Corp. 19 Abbot Street Andover, Ma 01810 +1-866-437-0044 www.air-us.com 40460265 Rev. 1
Owner’s Manual and
Installation Instructions
Model ARS-1000

The ICON clean air delivery system is your best protection against harmful
indoor air pollution such as pollen, bacteria, mold, fungus and viruses.
The ICON delivers operating room quality air in the comfort of your home
and creates a positive pressurized protective shield preventing the
infiltration of harmful airborne contamination.
The process starts by taking in and conditioning fresh outdoor air that is
free of indoor airborne pollution. The air is then sterilized by exposing it,
for a prolonged period of time, to high output germicidal ultraviolet light
(UVC) using the same laminar air flow technology as used in a hospital
operating room. Combining this technology with a custom designed HEPA
filter, the air is cleaned to a 99.999% purity level and delivered into your
home. Simultaneously, the ICON’s proprietary software and patented
control system creates a positive pressurized environment and forms a
protective shield throughout your home.
The ICON is easily installed in a standard double hung window. *
* For “standard” wood or vinyl double hung windows meeting the
minimum to maximum requirements. Custom double hung windows or
double hung windows not meeting the minimum to maximum
requirements may require semi-professional or professional installation.
Clean Air Delivery System
2

U.S. Patent No.: US7,625,277 B2 3
Owner’s Manual and
Installation Guide
WARNING !
! For your safety, the information in this manual must be followed to minimize the risk of
fire, electric shock or personal injury.
IMPORTANT SAFETY INFORMATION BEFORE INSTALLATION.
READ ALL INSTRUCTIONS BEFORE USING and OPERATING THE SYSTEM.
SAFETY PRECAUTIONS
Use this system only for its intended purpose as described in this Owner’s Manual.
This system has been designed to destroy and displace airborne microorganisms. This is accomplished with the use of high output germicidal
ultraviolet (UV) light. The germicidal UV light is a concentrated form of that portion of sunlight that causes sunburns. This system has been
manufactured to the highest standards to prevent exposure to the UV light under normal operating conditions. The standards include an
enclosed UV chamber and safety interlocks to prevent the unauthorized operation of the system. (see operating instructions) Any attempts to
operate the system in an unauthorized manner may cause serious injury.
Serious and painful eye and skin injuries can occur if tampering of the system results in direct viewing of the UV lamps.
There is a sensation of “sand” in the eyes photophobia, blurred vision and painful uncontrolled excessive blinking.
Symptoms may last up to 24 hours with the corneal pain being severe. Recovery takes I to 2 days.
Do not tamper with or dismantle the ICON system. Do not insert objects through the front of the ICON grill.
Install system in accordance with the installation instruction before use.
Never unplug your system by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Do not use a cord that shows cracks or abrasion damage along its length or at the plug .
If the supply cord is damaged, it must be replaced by the manufacturer, the service agent or similarly qualified person to avoid a hazard.
Do not attempt to service this system yourself. Call a certified repair or service tech.
For your safety… Do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this system.
If the wall receptacle does not match the plug the wall receptacle must be replaced by a qualified electrician. The wall receptacle must be a 3-
wire grounding type receptacle and match the supplied ICON power cord plug.
Do not, under any circumstance, cut or remove the third (ground) prong from the power cord. For personal safety, this system must be
grounded.
Do not use an adapter plug with this appliance.
We strongly recommend against the use of an extension cord. If you must use an extension cord, it necessary that it be a UL-listed, 14- gauge,
3-wire grounding-type appliance extension and that the electrical rating of the cord be 15 amps (minimum).
ICON –Five Year Limited Warranty
This Limited Warranty is extended only to the original purchaser who purchases this product when new and unused from American Innovative
Research Corp. (A.I.R.) or an authorized distributor. A.I.R. warrants that the ICON purchased hereunder will be free from defects in material and
workmanship under normal use by the original purchaser for a period of five (5) years from the original purchase date. If within such warranty
period the ICON shall be proven to be defective, A.I.R. shall, at its option, repair or replace the ICON. This Limited Warranty remains in effect only
if your A.I.R. warranty registration has been completed and returned to A.I.R. The foregoing shall be Purchaser’s sole and exclusive remedy for
any breach of warranty.
To register and validate your product simply fill out the warranty card and mail it to A.I.R. Corp., or on-line at www.air-us.com or by calling
customer support at 1.866.437.0044.
The foregoing shall be Purchaser’s sole and exclusive remedy for any breach of warranty.
Warranty Limitations or Disclaimers
THE FOREGOING WARRANTY SHALL NOT APPLY TO FAILURE TO ADHERE TO THE OPERATING INSTRUCTIONS, MISUSE, ACCIDENT, WEAR AND
TEAR, IMPROPER POWER CONNECTION, OR UNAUTHORIZED REPAIR. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE EXPRESSLY DISCLAIMED BY A.I.R.. THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY
SHALL BE LIMITED TO REPAIR, REPLACEMENT OF THE DEFECTIVE PRODUCT OR REFUND PURSUANT TO THE TERMS PROVIDED HEREIN. A.I.R.
SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE, OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE
EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE. THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE LAW AND
REQUIREMENTS.
To Obtain Warranty Service
All products you wish to return for warrant service must be accompanied by a Return Authorization Number (RA). This number and shipping
instructions can be obtained by contacting customer support at i[email protected] or call 1.866.437.0044.
IMPORTANT
You need to register your product by completing the warranty registration card that was enclosed in the shipping box and
return it by mail or register online at www.air-us.com or by telephone 1.866.437.0044.
If you have any questions contact customer support at 1.866.437.0044.
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement

Manuel du propriétaire et du Guide d’installation
CONSIGNES DE SECURITÉ
Utilisez ce systéme seulement pour usage prévu comme décrit dans ce manuel du propriétaire
Ce système a été conçu pour détruire les microorganismes. Ceci est accompli avec l’utilisation de la sortie ultraviolet (UV) germicide.
La lumière UV germicide est une forme concentrée de cette partie de la lumière du soleil qui provoque leas coups du soleil. Ce
système a été fabriqué por les plus hauts standards pour prévenir l’exposition à la lumière UV dans les conditions normales
d’exploitation. Les normes comprennent une chambre UV et verrous de sécurité pour empêcher l’exploitation non autorisée du
système. (voir les instructions de fonctionnement)
Toutes tentative pour faire fontionner le système d’une manière autorisèe peut entraîner des lessures graves.
ATTENTION: La lumière UV. Ne pas regarder directement la lumière. Oculaires graves et douloureux des lèsions cutanèes peuvent se
produire la trempe de les resultats de système de visualisation directe des lamp UV. Il y a une sensation de “sable” dans les yeux
photophobia, vision trouble et dolorous incontrôlée excessive clignoter. Les symptômes peuvent durer jusqu’à 24 heures avec la douler la
cornée étant sévère. La récupération prend de 1 à 2 jours.
Ne pas toucher avec ou démanteler le système ICON.
Ne pas insérer d’ojets étrangers à travers de la grille ICON.
ATTETNION: L’appareil ne doit pas être utilisé pas des enfants oudes personnes don’t les capacités physiques, sensorielles ou
mentalesou le manqué d’experience et de connaissances, à moins qu’elles n’aient été donnés de supervision ou d’enseignement. Les
enfant doivent être surveillés pour ne jouer avec l’appareil.
Ce système doit être correctement installé conformément aux instructions d’installation avant l’utilisation.
Jamais arrêter votre système en tirant sur le cordon d’alimentation. Saisissez toujours fermement et tirez de la prise.
Ne pas utiliser un cordon qui a des fissures ou de dommagé, à l’abrasion sur toute sa longeur ou à la fiche ou l’extrémité du
connecteur. Dans le cas où votre cordon est endommagé, contactez immédiatement le fabricant. L’extrémité du connectecteur. Dans
le cas où votre cordon est dommagé, contactez immédiatement le fabricant.
Éteindez le système et débranchez votre système avant de nettoyer.
Ne pas essayer de réparer ce système vous-même. Appelez un technicien certifié de réparation ou de service.
Por votre sécurité… Ne pas utiliser des matrériaux combustibles, essences ou autres vapeurs ou liquides flammables dans le voisinage
de ce système.
Si la prise murale ne correspond pas à la fiche de la prise murale, la prise doit être remplacée par un electrician qualifié. La prise murale
doit être un réceptacle 3-fil de type de terre et correspondent à la prise ICON cordon d’alimentation fournie.
Ne pas, sous aucune circonstance, couper ou enlever la troisième (terre) du cordon d’alimentation. Pour votre sécurité, ce système
doit être mis à la terre.
Ne pas utiliser un adaptateur avec cet appareil.
Nous recommendons fortement contre l’utilisation d’un cordon extension. Si vous devez utiliser une rallonge, il est necessaire que ce
soit un UL, de calibre 14, 3 fils extension de l’appareil de type de terre et que les caractéristiques électriques du cordon de 15 ampère
(au minimum).
Pour l’appareil clientèle de soutuen 1.866.437.0044. U.S. Patent No.: US7,625,277B2
4

ICON –Installation Instructions
Questions? Call +1.866.437.0044 to speak with a person in customer support.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT - Save these instructions for future
reference.
• IMPORTANT - Observe all governing codes and
ordinances.
• Skill level - Installation of this appliance
requires basic mechanical skills.
• Install time - Approximately 1 hour
• We recommend that two people install this
product.
• Proper installation is the responsibility of the
owner/installer.
• Product failure due to improper installation is not
covered under the Warranty.
• Use proper installation procedures as described in
these instructions when installing this system.
Installation may not require the use of all of the clips
or hardware.
I ELECTRICAL REQUIREMENT
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
5
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
UNPACK THE CONTENTS
1 Window kit
top rail
3 #8 Sheet
Metal Screws
White Head
Window
Sash Seal
(1)
Foam top
window
gasket (1)
Window
Locking
Bracket (1)
3 Wood
Screws
Owner’s
Manual
Air flow
Demonstration
Kit
Window Installation Kit
Warranty
Card
ICON System
Medium Scissors
#3 0r #4 Phillips head screwdriver
Note: A drill may be required for pilot holes.
TOOLS YOU WILL NEED
CAUTION:
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of The ICON system.
Aluminum house wiring may present special
problems—consult a qualified electrician.
ATTENTION : Ne pas, dans aucune circonstance, coupe
ou enlever la troisième fourche (de la terre) du cordon
de secteur.
Ne changez pas la prise sur le cordon de secteur du
système d'ICÔNE.
Le câblage en aluminium de maison peut présenter
spécial problème-consultent un électricien qualifié.
! !
!
Left Panel Right Panel
Ships disassembled:
1 left & 1 right side frame
1 measuring lined cover panel
3 unlined cover panels
2 insulation foam

1WINDOW REQUIREMENTS
After selecting the best window location for your
ICON system, the window must be measured.
The window area should be free from any
obstructions inside and outside of your home to
adhere to min/max requirements.
The electrical outlet must be within six feet of
center of the window sill.
ICON –Installation Instructions for Double Hung Windows
4 TRIMMING THE SIDE PANELS
One of the 4 panels will be marked with numbers and lines
on the white side of the panel. Cut this panel on the line with
the same number as recorded in the box in step 3. This panel is
now the cutting template.
Example: if the recorded number is 10; cut along line 10
Using the template from above,
Cut the 3 remaining panels and
The two pieces of insulation
foam to the same size as the
Cutting template.
Place the template on top of
the 2 foam pieces and the
remaining 3 panels one at a
time and cut each piece .
6
Double Hung Window
24 inches Min.
36 inches Max.
_____
13 inches
Minimum
______
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
2WINDOW KIT ASSEMBLY
The top mounting rail of the window kit includes a
measuring guide.
Assemble the window frame
according to the diagram
below.
Left Frame
Note
Orientation
Right Frame
Note
Orientation
Left side
bottom rail
Right side
bottom rail
Top mounting rail
w/measuring guide
3 WINDOW KIT cont.
Open the window the ICON will be installed in.
With the tall side of the top mounting rail toward you
place the 3 assembled parts into the frame of the
window.
The bottom rail of the left and right frames should be
beyond the back of the sill and flush up against it.
Push the left and right window panel frames, firmly
against the window frame in the track of the window.
The frame is now in the same position as in the final
assembly.
Position check –close the window, the window frame
should close past the tall edge of the top window bracket
and flush to it, reopen the window and proceed.
Window Sill
Slide the top rail left or right so that the exposed
numbers are the same at both ends of the top rail.
Example: (10 –10 or 20 –20)
Record the number in the box to the right:
this will be used for cutting the insulation and the side panels to the
proper size for the window. Remove the assembled parts from the
window.

8INSTALL THE ICON IN THE WINDOW –One side at a time
AOpen the window to the maximum height.
Lift or remove the screen or storm window, if applicable.
B Place the ICON on the window sill at a slight left to right angle.
Holding the system firmly to support the weight, slide the
system bottom rail past the window sill. Install the ICON one
side at a time. Set one side into the window track and then
pull the system toward you until the other side is firmly in the
opposite window track.
C Lower the upper window. The bottom of the window sash
should rest on top of the unit. The face of the top mounting
rail must be flush with the window sash.
D Make sure the left & right panel frames are tight against
window tracks channels.
E Install the frame locking screws (2 –supplied with kit) on the
right (1) and left (1) side rails in the upper window frame sash
as illustrated above.
NOTE: To prevent the window frame from splitting, it maybe
necessary to drill pilot holes before driving the screws.
ICON –Installation Instructions
7
7STORM WINDOW REQUIREMENTS
The following steps only apply when a storm window exists
on the window the ICON is being installed in and it restricts
proper installation.
A storm window frame may not allow the ICON to tilt toward
the outside, and will keep it from draining properly.
To adjust for this, attach a piece of wood on the sill and flush
to the back of the sill.
WOOD PIECES (not supplied)
WIDTH: 2"
LENGTH: Long enough to fit inside the window frame from
side to side.
THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2“ higher than the top
of the storm window frame or the vinyl frame. Attach
securely.
½” higher than
storm window frame
Storm
window frame Frame
Sill
Wood
½” higher than vinyl
frame (on some windows)
6 PREPARE THE ICON WINDOW
Cut the window sash seal foam tape to the
proper length to fit the entire length of the underside
of the window sash.
This is the thin foam
tape with the
adhesive backing.
Remove the paper
backing and press
the adhesive side
of the foam to the
under side of the
sash as shown.
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
5ASSEMBLE THE TRIMMED SIDE PANELS
Assemble covers, foam and frame a shown
below and set aside.
Attach the top mounting rail to the ICON with 3
sheet metal white head screws in the window kit. The
tall mounting rail edge must be oriented toward the
front of the ICON system.
Insert the side panels assemblies into the top and
bottom rail and push the assemblies firmly against
the shell of the ICON. Make sure the plastic panels are
inside the frame on all sides, front and back.
Insulation
Plastic
Panel
cover
White side of panel facing toward the foam
Plastic
cover

9INSTALL WINDOW LOCKING BRACKET AND FOAM WINDOW GASKET
AAttach the window locking bracket to the window side jam with one screw as
illustrated below.
CAUTION:
To prevent broken glass or damage to windows, on vinyl or other similarly
constructed windows, attach the window locking bracket to the window side
jam with one screw.
BCut the foam window gasket to fill the entire opening length between upper
window pane and the top frame of the lower window.
CSlide the cut foam between the outer window pane and the inside window frame top.
NOTE: If the gasket supplied does not fit your window, the appropriate
material and size can be obtained from your local hardware store
to provide a proper insulation seal.
ICON –Installation Instructions
8
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement

ICON –Operating Instructions
9
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
ICON –Care and Cleaning
Grill and Enclosure Care
To clean the surface of the system, wipe with a damp
clean cloth.
DO NOT USE
Detergents, bleach, ammonia or abrasives
to clean the ICON.
Display LED (viewed through grill)
When the system is plugged into a 110-120 AC
grounded outlet the display LED will light up and
appear as a combination of orange and green.
When the system is turned ON the display LED
will turn Green.
If the display LED flashes red refer to the
troubleshooting section of the manual. 110-120 V AC 15A (Min.)
Grounded Outlet
Power Cord
Power On / Off
To turn the system ON: Press and hold the power On/Off
Switch, the display LED will turn green, release the power
switch.
To turn the system OFF: Press and hold the power On/Off
Switch, the display LED will appear as a combination of
orange and green, release the power On/Off switch.
Power Outage or Interruption
In the case of a power outage or interruption,
when power is restored the ICON will
automatically reset to the last operating
conditions before the power interruption.
Power
ON/Off
Switch
Please Note:
When the weather conditions are severe please turn off the ICON system.
When the ICON is powered up the on-board computer automatically adjusts the ICON to deliver clean, fresh,
sterile air into your home.
If the green LED display light is on –the ICON is running.
When operating under "normal" conditions the
ICON system is extremely quiet. You should hear the
soft hum of the small (muffin) fan, the operating hum
is whisper quiet.
If you are still uncertain if the system is operating,
follow the demonstration test kit procedure (included) .

Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
10
Filter Cleaning or Replacement
A.I.R. Corp. recommends cleaning the aluminum mesh pre-filter every six months and changing the
removable cartridge (UV lamps, HEPA and carbon filters) every 24 months.
Before replacing the pre-filter, turn the system off and unplug the system from the
wall outlet.
1. Remove the Grill
Be Careful not to drop the Grill.
Remove the grill by using the finger
holes on the upper left and right of the grill.
Pull the top of the grill forward a few inches
while applying a slight downward pressure
on the grill. The downward pressure will keep
the two locating tabs at the bottom of the grill
in the corresponding locating slots in the enclosure.
Grasp the upper corners of the grill firmly and lift
the grill up and out of the ICON enclosure.
2. Remove the Pre-filter.
The aluminum mesh filter can now be
removed for washing or replacement
by pulling the plastic tab on the front
center of the filter and sliding the filter
out of the system.
3. Washing the pre-filter.
Wash the pre-filter with detergent and a soft
bristle brush. Rinse the pre-filter thoroughly
with clean water and dry it using a soft cloth.
Pre-Filter Cleaning or Replacement
Grill
Finger Holes
Pre-filter
Plastic tab Pull filter straight out
ICON
enclosure

Filter Cleaning or Replacement
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
11
4. Replacing the Pre-filter
Replace the pre-filter by aligning the filter
in the pre-filter channel with the plastic
tab facing up and out and firmly pushing
the filter into the system.
5. Replacing the front grill
With the front of the grill facing you and
finger holes along the top, grasp the
upper left and right corners of the grill.
Hold the grill at a slight angle and align
the two locating tabs at the bottom of
the grill with the two grill locating slots
at the bottom of the grill opening of the
ICON system enclosure. Insert the
tabs in the slots and push the top of the
grill into place and the
magnetic catch will “pop” the grill into
position.
Pre-filter
channel
Push filter
straight in
Clean washed or
new filter
Grill locating tabs & slots
Grill attachment magnets
Replace the UV Lamps, HEPA and Carbon Filter Cartridge
Replacing the Cartridge
A The system computer has a run time clock that keeps track of the total time the system has
been running.
B At the end of 24 months of accumulated run time the LED display will continuously flash RED
indicating it is time to replace the ICON cartridge.
C A.I.R. Corp. has designed an easily replaceable cartridge assembly to simplify the 2 year
maintenance. The cartridge contains the germicidal UV lamps and the HEPA and carbon filters.
The cartridge is the heart of the system and should be changed to optimize system
performance and provide the highest quality and amount of clean, fresh, particle free air possible.
After two years of continuous operation when the LED display continuously flashes red the
system will continue to operate, however you should contact customer support at
1.866.437.0044 to order a new cartridge assembly .

ICON –Troubleshooting Tips
LED Display Color Problem Possible Causes What To Do
Not lit ICON does not start.
The ICON is unplugged.
Make sure the ICON's power cord plugs
are pushed completely into the wall
outlet.
The circuit breaker is tripped.
Check the house fuse/circuit breaker box
and replace the fuse or reset the breaker
if necessary.
Make sure that the electrical outlet is not
controlled by a light switch.
Note: Some room receptacles are
controlled by a switch located in the
room or elsewhere.
Turn the light switch controlling the
electrical outlet to the on position.
Bezel is not seated properly against the
system.
Insure the top of the grill is properly
installed (page 11, step #5).
Not lit
The ICON is running but
the display area does
not illuminate.
The display LED malfunctioned
Do not attempt to dismantle the unit. Call
A.I.R. Corp. for service at
+1-866-437-0044.
Green
The ICON is ON but
there is no air flow
coming out of the
front of the system.
Airflow is restricted.
Condition can be confirmed by use of the
air flow demonstration kit.
Make sure there are no curtains, blinds or
furniture blocking the front of the ICON.
Remove snow , ice or leaves blocking the
input.
Clean the pre-filter.
The ICON chamber fan is not working.
Condition can be confirmed by use of the
air flow demonstration kit.
Do not attempt to dismantle the system.
Call A.I.R. Corp. for service at
+1-866-437-0044.
Green
The Fan on the back
of the ICON is not
working.
The fan visible in the rear of the system is
part of the dehumidify section. This fan
will only turn on if the air is humid
or hot. It is normal for the fan to be
stopped when the temperature and
humidity are normal.
This is normal system operation.
Green
Water drips outside.
Hot, humid weather.
This is normal.
Red Flashing
(intermittent codes) ICON malfunction. Various.
Do not attempt to dismantle the system.
Call A.I.R. Corp. for service at
+1-866-437-0044.
Red
Flashing
continuously
2 year maintenance
required.
ICON operational for a total of 2 years
elapsed time.
Replace lamp and filter cartridge.
Do not attempt to dismantle the system.
Call A.I.R. Corp. for service at
+1-866-437-0044.
Normal Operating Sounds
You will hear a very low humming noise which is normal. This sound is generated by the constant flow of fresh sterile air into
your home. The unit will occasionally adjust the air pressure in your room to keep airborne contaminants from entering. You
will hear a temporary 1-2 second airflow adjustment sound which is normal.
12
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
NOTE: The first step to all problem conditions is to confirm that the electrical outlet is working properly. Check
the outlet with a working appliance or lamp.
Combination of
Orange & Green

ICON –Specifications
13
Safety
Instructions
Troubleshooting
Installation and
Setup
Care and
Cleaning
Operating
Instructions
Warranty
Specifications
Filter Replacement
ICON Specifications for Model ARS-1000
Positive Pressure Fresh Air Delivery System
Part Number: 40460000
The following specifications define the most advanced air sterilization system available to the public and
therefore can not be compared to specifications of a standard air cleaner.
Specifications
Air Flow
Fresh Air Delivery Rate 15 to 30 CFM Fresh Sterile Air
Positive Fresh Air Pressure 0.020 WC (0.0005 Psi) +/- 50%
Contaminated Air replacement Rate 21,600 CFM/day to 43,200 CFM/day
Filtration
Submicron HEPA Filter 99.997 % ≥ @ 0.3 microns Replaceable
Activated Carbon Filtration Replaceable
Average Filter Life 24 Months Continual Use*
Wire Mesh Pre-filter (washable) Replacement not required, unless damaged
Sterilization
Air Sterilization Effectiveness 99.9999% for sample pathogens
UVC Air Sterilization Ultraviolet germicidal radiation
Average UVC Lamp Life 24 Months Continual Use
Control Panel
ON/OFF Rocker Switch
Power Requirements
Voltage 110-120 VAC 60Hz (Grounded)
Power –Normal Operation 90 watts
Power Cord 7 feet
Fresh Air Treatment
Air Heated at 10⁰ below zero 0 –650 watts (max.)
Air Dehumidified Maximum 0 –120 watts
Air Cooled Maximum 0 –120 watts
Physical Data
ICON Dimensions (in inches)
Window Kit
Weight of ICON & Window Kit 32 Pounds
ICON Construction
External Components Electrostatic painted Aluminum
Accessories
Window Kit (Assembly Required) Included
Owners Manual & Warranty Card Included
Test Kit Included
Shipping Information
Box Size in Inches 25.5”L x 23.5”W x 19.25”H
Shipping Weight 41.0 Pounds
…………………………………………………………………………………………….
* Factors effecting Filter Life
•Outside environment • Hours of operation
Note: Submicron HEPA filter and Activated Carbon filter must be replaced within 24 months.
All technical specifications are subject to change without prior notice. DOC: 40450264 Rev.E
Min. Window Opening with window kit
36 “
Max. Window Opening
18 “ wide
20 “ Long
24 “
15” High
105/8”
8¼”
Top View

ICON ARS- 1000 Accessories & Replacement Filters
14
American Innovative Research Corp. 19 Abbot Street Andover, MA 01810 +1-866-437-0044 www.air-us.com
ICON Cartridge Assembly Replace every 24 months of continuous use.
p/n: 40460280 The cartridge assembly includes the UV lamps &
bulb assembly and the HEPA and charcoal filters.
ICON UV Lamp & Bulb Assembly Replace every 24 months of continuous use.
p/n: 40460275 The UV Lamp & Bulb Assembly is contained in the
cartridge assembly.
ICON Submicron HEPA Filter Replace every 24 months of continuous use.
p/n: 40444072 The HEPA filter is contained in the cartridge
assembly.
ICON Activated Carbon Filter Replace every 24 months of continuous use.
p/n: 40460016 The Carbon filter is contained in the cartridge
assembly.
ICON Wire Mesh Pre-filter (washable) Replacement not required, unless damaged
p/n: 40460267
ICON Window cover/insulation kit As needed
p/n: 40450450
For pricing and ordering information please contact customer support at 1.866.437.0044
or our website at www.air-us.com.
Table of contents
Popular Air Cleaner manuals by other brands

Unitary products group
Unitary products group S1-EAC20002025 owner's manual

Five Seasons
Five Seasons SSC-7 Operation and maintenance manual

MaSSC Clean
MaSSC Clean MC-CA1 operating instructions

FIWOTTTDA
FIWOTTTDA BREATHE NATURE 01 user manual

IKEA
IKEA UPPÅTVIND quick start guide

Philips
Philips AC6606 user manual

Baileigh Industrial
Baileigh Industrial AFS-1000 Operator's manual

Honeywell
Honeywell HFD-010 - Room Air Purifier owner's manual

Helios
Helios AirPal 1750 H Installation and operating instructions

IQAir
IQAir CleanZone 3030 series manual

Alen
Alen A375 user manual

WELLISAIR
WELLISAIR WADU-02 user manual