iManifold®App Screen
Easily map probes to assigned locations
Tap to change refrigerant
Superheat Scale Target superheat
(+/- 5°F) depicted in yellow & green
center band per ACCA-QI guidelines
Target Suction Pressure Appears when
system is proled. Dynamic indicator
displays target saturation (+/- 3°F)
Vacuum
Indicator
(not microns)
Temperature Inputs Suction Line Temp, Liquid Line
Temp, Discharge Line Temp, Outdoor Air Temp all
remappable to wired probes. Values change color when
streamed in via Bluetooth, overriding user inputs.
Evaporator Temperatures Supply Air Dry
Bulb, Supply Air Wet Bulb, Return Air Dry Bulb,
Return Air Wet Bulb
Calculated Targets Target Suction
Pressure, Target Superheat, Target Sub-cooling,
Target High Pressure when system is proled
Dynamic Range Max scale depending on
refrigerant selected. Overload pressures displayed
on bands.
Subcooling Scale Target subcooling (+/- 3°F)
depicted in yellow & orange center band per
ACCA-QI guidelines
Target High/Head Pressure Appears when
system is proled. Dynamic indicator displays
target saturation (+/- 3°F)
Discharge Line Temperature Max 225°F monitor
to protect against oil failure
App available on Google Play and Apple App Store
Search‘iManifold’
Capacity & Eciency Cooling tons,
BTU/hr, kW, EER shown only when all
required user inputs are added
See us at the