I-7018(R)(BL)(P), M-7018(R) Quick Start Guide
Warranty
All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages resulting from the use of this product. ICP DAS reserves the right to change this
manual at any time without notification. The information furnished by ICP DAS is believed to be accurate and reliable.
However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third
parties resulting from its use.
Packing List
I-7018(R)(BL)(P) or M-7018(R)
Plastic Rail
CD
Quick Start Guide
Internal I/O Structure < I-7018(BL)(P), M-7018 >
Pin Assignments < I-7018(BL)(P) >
Pin Assignments
< I-7018R, M-7018, M-7018R >
Internal I/O Structure < I-7018R, M-7018R >
Wire Connections < I-7018(BL)(P) Channel 0 –5, M-7018 , I-7018R, M-7018R >
Page 1
Wire Connections < I-7018(BL)(P) Channel 6 –7 >
Modbus Table (M-7018, M-7018R only)
Address
Description
R/W
30001 ~
30008
40001 ~
40008
Analog input value of channel 0 to 7
R
30129
40129
CJC temperature in 0.01°C
R
40353 ~
40360
CJC offset of channel 0 to 7 in 0.1°C.
1 for 0.1, 127 for 12.7, 255 for –0.1,
128 for –12.8
R/W
40481
Firmware version (low word)
R
40482
Firmware version (high word)
R
40483
Module name (low word)
R
40484
Module name (high word)
R
40485
Module address, valid range: 1 ~ 247
R/W
40486
Bits 5:0
Baud rate, 0x03 ~ 0x0A
Code
0x03
0x04
0x05
0x06
Baud
1200
2400
4800
9600
Code
0x07
0x08
0x09
0x0A
Baud
19200
38400
57600
115200
Bits 7:6
00: no parity, 1 stop bit
01: no parity, 2 stop bit
10: even parity, 1 stop bit
11: odd parity, 1 stop bit
R/W
40487
Type code
R/W
Address
Description
R/W
40488
Modbus response delay time in ms,
valid range: 0 ~ 30
R/W
40489
Host watchdog timeout value, 0 ~
255, in 0.1s
R/W
40490
Channel enable/disable, 00h ~ FFh
R/W
40491
Module CJC offset in 0.01°C
R/W
40492
Host watchdog timeout count, write 0
to clear
R/W
00257
Protocol, 0: DCON, 1: Modbus RTU
R/W
00259
Filter setting, 0: 60Hz rejection, 1:
50Hz rejection
R/W
00260
Modbus host watchdog mode
0: same as I-7000
1: can use AO and DO command to
clear host watchdog timeout status
00261
1: enable, 0: disable host watchdog
R/W
00268
1: enable, 0: disable CJC
R/W
00269
Modbus data format, 0: hex, 1:
engineering
R/W
00270
Host watch dog timeout status, write
1 to clear host watch dog timeout
status
R/W
00273
Reset status, 1: first read after
powered on, 0: not the first read after
powered on
R
DCON Protocol
Functions
Command
Response
Notes
Read module name
$AAM
!AA(Data)
AA: address number
Read module firmware version
$AAF
!AA(Data)
Read all analog input data
#aa
>(data)
Read analog input data of each channel (<=16 channel)
#aai
>(data)
i: channel number (Hex)
Read analog input data of each channel (>16 channel)
#aaii
>(data)
ii: channel number (Hex)
Page 2
Module test and configuration
Step 1: INIT switch Operation
1. Find out the INIT switch( back of the module),
and turn to INIT.
2. Reboot the module
Step 2: Install & Run DCON Utility
1. Please Install DCON Utility first
You can find the software in the CD.
CD path:
<Driver>:\napdos\driver\dcon_utility\
Web link:
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
2. Run DCON utility
Step 3: Set search configuration & search module
Step 4: Select Module for testing and configuration
1. Click “COM Port”
2. Assign the communication information and click
“OK”
Module Default Setting
COM Port
Refer converter Port Number
Baud Rate
9600
Protocol
DCON for I-7000
Modbus RTU for M-7000
Parity Option
N,8,1
3. Click “Search” and select “Start Searching”
Software will search the modules from COM Port
4. Click “Search“ and select “stop searching”
Manual stop when the modules searched
Note:
When no module can be searched, please check the
wire and communication information
Select COM Port Number
Double click “select module”
Page 3
Step 5: Configuration Settings & Channel Settings
Module Settings
Protocol
DCON / Modbus
Address
1~255 (0:INIT)
Baud rate
1200~115200
Parity option
N,8,1
Input range
Depends on signal
sources
Step 6: Change to normal mode and keep the settings
1. Turn the INIT Switch to Normal.
2. Reboot the module
Trouble Shooting
Q1. How to do when forgot module address or baud rate?
Please turn to INIT mode, and run DCON Utility to search.
The module supports DCON protocol at the INIT mode.
And the address is 0. The communication setting is “9600,N,8,1”.
Q2. How to configure the I-7000 and M-7000 modules?
ICP DAS provide DCON Utility to configure I-7000 and M-7000 modules.
Please download the last version from: http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
Q3. How to measure the current?
I-7018(R)(BL)(P) and M-7018(R) require optional external resistance (125Ω) for current measurement.
Please refer wired connections diagram.
And then select a suitable input range by DCON Utility.
Q4. What is the CJC function?
CJC (Cold-Junction Compensation) offset is for the temperature measurement.
You can set a CJC offset for all channels or different channel in DCON Utility,
Q5. How to programming with I-7000 or M-7000 by C#, VB, VC?
ICP DAS I-7000 and M-7000 series both support DCON protocol. And Only M-7000 series supports Modbus protocol.
For DCON protocol, please download SDK and Demo from:
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_dll_new/
For Modbus protocol, please refer this web link:
http://www.icpdas.com/products/PAC/i-8000/modbus.htm
Channel Status
CJC Offset
Temperature Offset Settings

This manual suits for next models

5

Other ICP DAS USA I/O System manuals

ICP DAS USA DN-8K32R User manual

ICP DAS USA

ICP DAS USA DN-8K32R User manual

ICP DAS USA M-7000 series User manual

ICP DAS USA

ICP DAS USA M-7000 series User manual

ICP DAS USA EIP-2000 Series User manual

ICP DAS USA

ICP DAS USA EIP-2000 Series User manual

ICP DAS USA PET-7044 User manual

ICP DAS USA

ICP DAS USA PET-7044 User manual

ICP DAS USA PETL Series User manual

ICP DAS USA

ICP DAS USA PETL Series User manual

ICP DAS USA tM-AD2 User manual

ICP DAS USA

ICP DAS USA tM-AD2 User manual

ICP DAS USA tM-P8 User manual

ICP DAS USA

ICP DAS USA tM-P8 User manual

ICP DAS USA ET-2254 User manual

ICP DAS USA

ICP DAS USA ET-2254 User manual

ICP DAS USA ET-2255U User manual

ICP DAS USA

ICP DAS USA ET-2255U User manual

ICP DAS USA I-9K Series User manual

ICP DAS USA

ICP DAS USA I-9K Series User manual

ICP DAS USA SG-3071-G User manual

ICP DAS USA

ICP DAS USA SG-3071-G User manual

ICP DAS USA UA-7200 Series User manual

ICP DAS USA

ICP DAS USA UA-7200 Series User manual

ICP DAS USA CAN-2057C User manual

ICP DAS USA

ICP DAS USA CAN-2057C User manual

ICP DAS USA M-7011 User manual

ICP DAS USA

ICP DAS USA M-7011 User manual

ICP DAS USA I-7000 Series User manual

ICP DAS USA

ICP DAS USA I-7000 Series User manual

ICP DAS USA EIP-2019 User manual

ICP DAS USA

ICP DAS USA EIP-2019 User manual

ICP DAS USA PET-7060 User manual

ICP DAS USA

ICP DAS USA PET-7060 User manual

ICP DAS USA PROFI-8455 Setup guide

ICP DAS USA

ICP DAS USA PROFI-8455 Setup guide

ICP DAS USA WF-2000 Series User manual

ICP DAS USA

ICP DAS USA WF-2000 Series User manual

ICP DAS USA I-2533 User manual

ICP DAS USA

ICP DAS USA I-2533 User manual

ICP DAS USA ISO-C64 User manual

ICP DAS USA

ICP DAS USA ISO-C64 User manual

ICP DAS USA I-7053 FG User manual

ICP DAS USA

ICP DAS USA I-7053 FG User manual

ICP DAS USA I-3591 User manual

ICP DAS USA

ICP DAS USA I-3591 User manual

ICP DAS USA PIO-D144 Series User manual

ICP DAS USA

ICP DAS USA PIO-D144 Series User manual

Popular I/O System manuals by other brands

Siemens SIMATIC ET 200AL manual

Siemens

Siemens SIMATIC ET 200AL manual

esera automation 11216 user guide

esera automation

esera automation 11216 user guide

FireClass FC410CIM Fixing instructions

FireClass

FireClass FC410CIM Fixing instructions

WAGO I/O System 750 Series manual

WAGO

WAGO I/O System 750 Series manual

Infinity IMS manual

Infinity

Infinity IMS manual

Whelen Engineering Company LFL LC Series Replacement guide

Whelen Engineering Company

Whelen Engineering Company LFL LC Series Replacement guide

Siemens SIMATIC ET 200R manual

Siemens

Siemens SIMATIC ET 200R manual

Optimus UMX-C16 operating instructions

Optimus

Optimus UMX-C16 operating instructions

I.O.T. Eport PRO-EP10 user manual

I.O.T.

I.O.T. Eport PRO-EP10 user manual

turck GDP-N/FW2.3 Integration manual

turck

turck GDP-N/FW2.3 Integration manual

IFM AL4102 operating instructions

IFM

IFM AL4102 operating instructions

ABB FDIO-01 user manual

ABB

ABB FDIO-01 user manual

RJG Lynx OA1-M-V product manual

RJG

RJG Lynx OA1-M-V product manual

GE AF-600 FP Series manual

GE

GE AF-600 FP Series manual

Rockwell Automation Allen-Bradley 1769-ASCII user manual

Rockwell Automation

Rockwell Automation Allen-Bradley 1769-ASCII user manual

National Instruments REM-11152 Getting started guide

National Instruments

National Instruments REM-11152 Getting started guide

Telepro HEIM-48 Installation & operation manual

Telepro

Telepro HEIM-48 Installation & operation manual

HomeMatic HmIPW-FIO6 Installation instructions and operating manual

HomeMatic

HomeMatic HmIPW-FIO6 Installation instructions and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.