Ideal Air DUAL MINI-SPLIT User manual

REMOTE MANUAL
All the illustrations in the manual are for explanation purpose only.
Your machine may be slightly different. The actual shape shall prevail.
PRO |DUAL MINI-SPLIT
REMOTE CONTROL
APPLIES TO THESE MODELS:
700021 • 700023 • 700024 • 700025 • 700026 • 700027 • 700028 • 700029 • 700807 • 700808

READ THIS MANUAL
CONGRATULATIONS...
Thank you for purchasing this air conditioner. This manual will provide you with information on how
to operate, maintain, and troubleshoot your remote control.
on your purchase of Ideal Air’s Pro | Dual Mini-Split Air Conditioner/Heat Pump. We’re proud to offer this
product and believe it’s the very best in its class.
2
REMOTE CONTROL SPECIFICATIONS........................................................................................2
OPERATION BUTTONS....................................................................................................................3
INDICATORS ON LCD .....................................................................................................................6
HOW TO USE THE BUTTONS.........................................................................................................7
AUTO OPERATION .......................................................................................................................7
COOLING/HEATING/FAN OPERATION....................................................................................7
DEHUMIDIFYING OPERATION .................................................................................................8
TIMER OPERATION ......................................................................................................................8
HANDLING THE REMOTE CONTROL........................................................................................11
CONTENTS
NOTE:
• All the functions described are accomplished by the unit.
• When there are wide differences between remote control illustration and USER'S MANUAL on
function description, the description of USER'S MANUAL shall prevail.
REMOTE CONTROL
SPECIFICATIONS
Model
Rated Voltage
8m
3.0V (Dry batteries R03/LR03×2)
RG57A6/BGEFU1
Environment
Signal Receiving
Range
23° F~140° F
MODE
FAN
TEMP
SLEEP
SWING DI RECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
F P
TIMER
O N
TIMER
O FF

3
OPERATION BUTTONS
1ON/OFF BUTTON
This button turns the air conditioner ON and OFF.
2 MODE BUTTON
Press this button to modify the air
conditioner mode in a sequence of following:
3 FAN BUTTON
Used to select the fan speed in four steps:
4 SLEEP BUTTON
Active/Disable sleep function. It can maintain
the most comfortable temperature and save
energy. This function is available on COOL,
HEAT or AUTO mode only.
5 TURBO BUTTON
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temperature
at cooling or heating operation in the shortest
time (if the indoor unit does not support this
function, there is no corresponding operation
happened when pressing this button.)
6 SELF CLEAN BUTTON
Active/Disable Self Clean function. Under SELF
CLEAN mode, the air conditioner will
automatically clean and dry the evaporator
and keep it fresh for the next operation.
AUTO COOL DRY HEAT FAN
LOW MEDIUM HIGH AUTO
NOTE:
You can not switch the fan speed in
AUTO or DRY mode.
NOTE:
While the unit is running under SLEEP
mode, it would be canceled if MODE,
FAN SPEED or ON/OFF button is pressed.
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
3
4
5
6
bk
bm
bl
bn
bo
9
8
7

4
7UP BUTTON ( )
Push this button to increase the indoor
temperature setting by 1º F increments to 86º F.
DOWN BUTTON ( )
Push this button to decrease the indoor
temperature setting by 1º F increments to 62º F.
8 SILENCE/FP BUTTON
Active/Disable Silence function. If pushing
more than 2 seconds, the Silence function will
be activated, pushing more than 2 seconds
again to disable.
When the Silence function is activated, the
compressor will operate at low frequency
and the indoor unit will bring faint breeze,
which will reduce the noise to the lowest
level and create a quiet and comfortable room
for you. Due to low frequency operation of
compressor, it may result in insufficient
cooling and heating capacity.
The Silence function can only be activated
during the heating operation (only when the
setting mode is HEAT). The unit will operate
at a setting temperature of 46º F. The display
window of the indoor unit will display FP.
Pressing the buttons ON/OFF, SLEEP, SILENCE/FP,
MODE, FAN SPEED, UP or DOWN while
operating will cancel the Silence function.
9 TIMER ON BUTTON
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the auto-timed
setting 60 minutes increments. To cancel the
auto-timed program, simply adjust the
auto-on time to 0.0.
NOTE:
Press and hold UP and DOWN buttons
together for 3 seconds will alternate
the temperature display between the
ºC and ºF scale.
NOTE:
Temperature control is not available
in FAN mode.
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
3
4
5
6
bk
bm
bl
bn
bo
9
8
7

5
bkTIMER OFF BUTTON
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the auto-timed
program, simply adjust the auto-off time to 0.0.
bl SWING BUTTON
Used to stop or start horizontal louver auto
swing feature.
bm DIRECT BUTTON
Used to change the louver movement and set
the desired up/down air flow direction. The
lovers can be changed 6 inches for each time
the swing button is pressed.
bn FOLLOW ME BUTTON
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote
control will send this signal to the air
conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will cancel the Follow Me feature
automatically if it does not receive the signal
during any 7 minutes interval.
bo LED BUTTON
Disable/Active indoor screen display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
3
4
5
6
bk
bm
bl
bn
bo
9
8
7

6
MODE DISPLAY
Displayed when data transmitted.
Displayed when remote control is ON.
Battery display (low battery detection).
Not available for this unit.
Displayed when TIMER ON time is set.
Displayed when TIMER OFF time is set.
Show set temperature or room temperature,
or time under TIMER setting.
Displayed in SLEEP MODE operation.
Indicated that the air conditioner is operating
in FOLLOW ME mode.
Not available for this unit.
Not available for this unit.
FAN SPEED INDICATION
Low speed
Medium speed
High speed
Auto fan speed
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING D IREC T
LED FOLL OW
ME
TURB O SELF
CLEA N
ON/OFF
SILENC E
F P
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
INDICATORS ON LCD
Information is displayed when the remote control is powered up.
NOTE:
All indicators shown in the figure are for the
purpose of clear presentation. But during the actual
operation only the relative functional signs are
shown on the display window.

7
AUTO OPERATION
Ensure the unit is plugged in and power is available.
The OPERATION indicator on the display panel of the
indoor unit starts flashing.
1. Press the MODE button to select AUTO.
2. Press the UP/DOWN button to set the
desired temperature. The temperature can
be set within a range of 62º F~86º F in 1º F
increments.
3. Press the ON/OFF button to start the air
conditioner.
COOLING/HEATING/FAN OPERATION
Ensure the unit is plugged in and power is available.
1. Press the MODE button to select COOL,
HEAT (cooling and heating models only) or
FAN mode.
2. Press the UP/DOWN buttons to set the
desired temperature. The temperature can
be set within a range of 62º F~86º F in 1º F
increments.
3. Press the FAN button to select the fan
speed
i
n four steps - AUTO, LOW, MED, or HIGH.
4. Press the ON/OFF button to start the air
conditioner.
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
3
4
1
1
3
2
2
HOW TO USE THE BUTTONS
NOTE:
1. In the AUTO mode, the air conditioner can
logically choose the mode of cooling, fan,
and heating by sensing the difference
between the actual ambient room
temperature and the setting temperature
on the remote control.
2. In the AUTO mode, you cannot switch the
fan speed. It has already been automatically
controlled.
3. If the AUTO mode is not comfortable for
you, the desired mode can be selected
manually.
NOTE:
In the FAN mode, the temperature is not
displayed on the remote controller and
you are not able to control the room
temperature either. In this case, only step
1, 3 and 4 may be performed.

8
DEHUMIDIFYING OPERATION
Ensure the unit is plugged in and power is available. The
OPERATION indicator on the display panel of the indoor unit
starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the desired
temperature. The temperature can be set within a
range of 62º F~86º F in 1º F increments.
3. Press the ON/OFF button to start the air conditioner.
TIMER OPERATION
Press the TIMER ON button can set the auto-on time of the unit.
Press the TIMER OFF button can set the auto-off time of the unit.
TO SET THE AUTO-ON TIME.
1. Press the TIMER ON button. The remote control
shows TIMER ON, the last auto-on setting time
and the signal "H" will be shown on the LCD
display area. Now it is ready to reset the auto-on
time to START the operation.
2. Push the TIMER ON button again to set desired
auto-on time. Each time you press the button, the
time increases by half an hour between 0 and 10
hours and by one hour between 10 and 24 hours.
3. After setting the TIMER ON ,there will be a one
second delay before the remote control transmits
the signal to the air conditioner. Then, after
approximately another 2 seconds, the signal
"H" will disappear and the set temperature will
re-appear on the LCD display window of the remote.
TO SET THE AUTO-OFF TIME.
1. Press the TIMER OFF button. The remote control
shows TIMER OFF, the last auto-off setting time
and the signal "H" will be shown on the LCD
display area. Now it is ready to reset the auto-off
time to stop the operation.
2. Push the TIMER OFF button again to set desired
Auto-off time. Each time you press the button, the
time increases by half an hour between 0 and 10
hours and by one hour between 10 and 24 hours.
3. After setting the TIMER OFF, there will be a one
second delay before the remote control transmits
the signal to the air conditioner. Then, after
approximately another 2 seconds, the signal "H "
will disappear and the set temperature will
re-appear on the LCD display window of the remote.
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
3
1
2
NOTE:
In the Dehumidifying mode, you cannot switch the
fan speed. It has already been automatically controlled.

9
CAUTION
• When you select the timer operation, the remote
control automatically transmits the timer signal to the
indoor unit for the specified time. Therefore, keep the
remote control in a location where it can transmit the
signal to the indoor unit properly.
• The effective operation time set by the remote control
for the timer function is limited to the following settings:
0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5,
7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15, 16, 17, 18,
19, 20, 21, 22, 23 and 24.
TIMER ON
(AUTO-ON OPERATION)
The TIMER ON feature is useful when you want the unit
to turn on automatically before you return home. The air
conditioner will automatically start operating at the set time.
EXAMPLE
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of
starting operation time and the signal "H" will
show on the display area.
2. Press the TIMER ON button to display "6.0H"
on the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the digital display area will
show the temperature again. The "TIMER ON"
indicator remains on and this function is activated.
TIMER OFF
(AUTO-OFF OPERATION)
The TIMER OFF feature is useful when you want the
unit to turn off automatically after you go to bed. The
air conditioner will stop automatically at the set time.
EXAMPLE
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of
stopping operation time and the signal "H" will
show on the display area.
2. Press the TIMER OFF button to display "10H" on
the TIMER OFF display of the remote control.
3. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
OFF" indicator remains on and this function is
activated.
Start
Off
6 hours later
Set
Stop
On
Set 10 hours later
EXAMPLE OF TIMER SETTING

bk
COMBINED TIMER
(SETTING BOTH ON AND OFF TIMERS
SIMULTANEOUSLY)
TIMER OFF TIMER ON
(On Stop Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in the
morning when you wake up or when you return home.
EXAMPLE
To stop the air conditioner 2 hours after setting and
start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display "2.0H"
on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to display "10H"
on the TIMER ON display .
5. Wait for 3 seconds and the digital display area
will show the temperature again. The
"TIMER
ON and TIMER OFF"
indicator remains on and this
function is activated.
TIMER ON TIMER OFF
(Off Start Stop operation)
This feature is useful when you want to start the air conditioner
before you wake up and stop it after you leave the house.
EXAMPLE
To start the air conditioner 2 hours after setting, and stop it 5
hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display "2.0H"
on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display "5.0H"
on the TIMER OFF display.
5. Wait for 3 seconds and the digital display area will
show the temperature again. The "TIMER ON and
TIMER OFF" indicator remains on and this function
is activated.
On
Stop
2 hours later
after setting
Set
Start
10 hours later
after setting
Off Stop
Start
2 hours later
after setting
5 hours later
after setting
Set

bl
LOCATION OF THE REMOTE CONTROL
Use the remote control within a distance of 8 meters/26 feet from the
appliance, pointing it towards the receiver. Reception is confirmed by a beep.
CAUTION
• The air conditioner will not operate if curtains, doors or other
materials block the signals from the remote control to the
indoor unit.
• Prevent any liquid from falling into the remote control. Do not
expose the remote control to direct sunlight or heat.
• If the infrared signal receiver on the indoor unit is exposed to
direct sunlight, the air conditioner may not function properly.
Use curtains to prevent the sunlight from falling on the receiver.
• If other electrical appliances react to the remote control, either
move these appliances or consult your local dealer.
• Do not drop the remote control. Handle with care.
• Do not place heavy objects on the remote control, or step on it.
CAUTION
• Do not mix old and new batteries or batteries of different types.
• Do not leave the batteries in the remote control if they are not
going to be used for 2 or 3 months.
• Do not dispose batteries as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
USING THE REMOTE CONTROL HOLDER
(OPTIONAL)
•
The remote control can be attached to a wall or pillar by using a
remote control holder (not supplied, purchased separately).
•
Before installing the remote control, check that the air conditioner
receives the signals properly.
• Install the remote control with two screws.
• For installing or removing the remote control, move it up or
down in the holder.
REPLACING BATTERIES
The following cases signify exhausted batteries. Replace old batteries with
new ones.
• Receiving beep is not emitted when a signal is transmitted.
• Indicator fades away.
The remote control is powered by two dry batteries (R03/LR03X2) housed in
the back rear part and protected by a cover.
1. Remove the cover in the rear part of the remote control.
2. Remove the old batteries and insert the new batteries, placing the (+)
and (-) ends correctly.
3. Install the cover back on.
8m
MODE
SW I NG T E MP
SH O R T C UT
F A N
SP E E D
T IME R
O F F
R ES E T L OC K
L E D
FO L L OW ME
TIME R
ON
TU R B O
SE L F C L E A N
DIR E C T
SL EEP
FRESH
HANDLING THE REMOTE
CONTROL
NOTE:
When the batteries are removed, the remote control erases all
programming. After inserting new batteries, the remote control
must be reprogrammed.

IMPORTANT
1-877-943-3251
Product not working properly?
Contact Ideal-AirTM support directly
at support@ideal-air.com or call
For answers to most common questions and a complete
technical support library please visit www.ideal-air.com
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal-AirTM for details,
updates and other information.
DO NOT return this product
to the store where you
purchased it.
This manual suits for next models
1
Table of contents
Popular Remote Control manuals by other brands

Flying Industry Development
Flying Industry Development S4C-DC06 quick guide

Ocelli
Ocelli Remote Control user guide

Samsung
Samsung MWR-WE10 installation manual

Philips
Philips SRU 5150/87 Instructions for use

Philips
Philips Pronto SBCRU960/00 Specifications

Philips
Philips Prestigo SRU8015/10 Instructions for use