iesy SDoT Server V3B User manual

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
2
von
27
User Manual V
-
180131
-
BHA00
Table of Contents
1 Safety Informations....................................................................................................................................................................................................................................................................4
1.1 Intentional usage ..................................................................................................................................................................................................................................................................4
1.2 General risks by ignoring the safety Informations.....................................................................................................................................................4
1.3 Safety Instructions ..............................................................................................................................................................................................................................................................5
1.4 External Overcurrent Protection.................................................................................................................................................................................................................5
1.5 Battery Change (optional).......................................................................................................................................................................................................................................5
1.6 Operating Installation Side..................................................................................................................................................................................................................................6
1.7 Service and Cleaning......................................................................................................................................................................................................................................................6
1.8 Product Liability.......................................................................................................................................................................................................................................................................6
1.9 Modifications and Structural Changes.............................................................................................................................................................................................7
1.10 Qualified Personnel..........................................................................................................................................................................................................................................................7
1.11 Symbols and Meanings..............................................................................................................................................................................................................................................8
2 Assembly SDoT-Server V3B.........................................................................................................................................................................................................................................9
3 Connection SDoT-Server V3B...............................................................................................................................................................................................................................10
3.1 Server Front Side.................................................................................................................................................................................................................................................................12
3.2 Server Rear Side ..................................................................................................................................................................................................................................................................13
3.3 Main Power Supply.........................................................................................................................................................................................................................................................13
3.4 Ground Connection........................................................................................................................................................................................................................................................14
3.5 Interface USB3.0 – U1 & U2..............................................................................................................................................................................................................................14
3.6 Network Interface (Ethernet & Mini Gigabit Interface) - N1 to N6................................................................................................14
3.7 Serial Interface RS232 – S1.................................................................................................................................................................................................................................14
3.8 Display-Port – V1..................................................................................................................................................................................................................................................................14
3.9 LC Touch-Display Modul – T1.........................................................................................................................................................................................................................15
3.10 Reset-Button - R1 ...............................................................................................................................................................................................................................................................15
3.11 Power on - Push-Button with LED - P1.........................................................................................................................................................................................15
4 Operating SDoT Server V3B.....................................................................................................................................................................................................................................16
4.1 Replacing the Audit-Hard Disk – H1...................................................................................................................................................................................................16

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
3
von
27
User Manual V
-
180131
-
BHA00
4.2 Starting the SDoT Server V3B......................................................................................................................................................................................................................17
4.3 LC-Touchdisplay – T1....................................................................................................................................................................................................................................................18
4.4 Shutdown and Restart............................................................................................................................................................................................................................................20
5 Waste disposal and Environmental protection......................................................................................................................................................................21
6 Package........................................................................................................................................................................................................................................................................................................21
7 FCC Compliance...........................................................................................................................................................................................................................................................................22
8 Block diagram ..................................................................................................................................................................................................................................................................................24
9 Dimensions (mm) SDoT Server V3B.........................................................................................................................................................................................................26
10 Revision Tracking ......................................................................................................................................................................................................................................................................27

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
4
von
27
User Manual V
-
180131
-
BHA00
Manufacturer
iesy GmbH
Darmcher Grund 22
D-58540 Meinerzhagen
Germany
1 Safety Informations
1.1 Intentional usage
To ensure safe operation, the system may only be operated in accordance with the information in
these operating instructions. During use, the legal and safety regulations required for the respective
application must also be observed. This also applies analogously to the use of accessories. Additional
safety precautions must be taken for systems that could cause major damage, loss of data or even
personal injury due to a malfunction. In the event of a malfunction, these precautions will ensure a
safe operating condition. Operating instructions and in particular the safety instructions have been
read and understood. The system may only be installed by trained and qualified personnel.
1.2 General risks by ignoring the safety Informations
The SDoT server V3B is state-of-the-art and safe to operate. The system may present residual risks if
it is used and operated improperly by untrained personnel. Any person responsible for installing,
commissioning, maintaining, or repairing the system must have read and understood the operating
instructions and, in particular, the safety notes. The system may only be installed by trained and
qualified personnel.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
5
von
27
User Manual V
-
180131
-
BHA00
1.3 Safety Instructions
Ground the unit properly
do not use damaged power cords, accessories or peripherals
before cleaning or servicing, disconnect the unit from the power supply by disconnecting
both power cables. Disconnect all connections, the potential equalisation at the front should
only be disconnected if necessary and as a last step
do not place or drop any objects on the unit. Do not insert foreign objects into the appliance
1.4 External Overcurrent Protection
Provide an external overcurrent protection device for the unit. The highest rated value of this device
is 16A.
1.5 Battery Change (optional)
The SDoT servers V3B have a battery compartment on the back of the 19" housing. It is only
necessary to replace the battery once an optional HSM module has been installed.
The administrator can find information on the status of the external battery in the software GUI
under Monitoring » Status information » HSM: External Battery (refer to user manual of the
SDoT Product).
1. unscrew the cover of the battery compartment with a coin
2. replace the battery:
AA 3.6 V
up to 2700 mAh
recommended: EVE ER14505V oder Saft LS14500
3. close the battery compartment again with the cover unscrewed
Observe the general notes on the disposal of rechargeable batteries and batteries of the country in
which the SDoT System V3B is used.
When disposing of batteries, comply with local regulations and laws.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
6
von
27
User Manual V
-
180131
-
BHA00
1.6 Operating Installation Side
Operating temperature: 0°C …+45°C
make sure that the fans and ventilation openings are not covered up
the permissible relative humidity at 45°C is 95 % (non-condensing) must be observed
the device must be protected from direct sunlight
1.7 Service and Cleaning
Clean the housing with a soft and slightly damp cloth. Never use solvents, as these could damage
the labelling or the housing. When cleaning, make sure that no liquid gets into the module or onto
the connections.
The fans and the redundant power supply provide interfaces that can be used for monitoring the
operating status. In the event of a fault, the corresponding component must be replaced.
1.8 Product Liability
In the following cases, the intended safety of the device may be impaired.
Liability for the device function then passes to the operator:
the device is not used according to the operating instructions
the device is used outside the described field of application (intended use)
unauthorized changes are made to the device by the operator

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
7
von
27
User Manual V
-
180131
-
BHA00
1.9 Modifications and Structural Changes
The system may not be modified in terms of design or safety without our express consent. Any
modification excludes liability on our part for any resulting damage. In particular, any repairs, soldering
work on the circuit boards (replacement of components) are prohibited. When replacing entire
assemblies, only original parts are to be used. The system was delivered from the factory with a fixed
hardware configuration. Modifications are only permitted within the scope of the possibilities
documented in the manuals.
1.10 Qualified Personnel
This appliance may only be used by qualified personnel and only in accordance with the technical
data in connection with the safety rules and regulations listed below. Qualified personnel are persons
who are familiar with the installation, assembly, commissioning and operation of the product and
have the qualifications appropriate to their job. This includes persons who meet at least one of the
following three requirements:
the persons are familiar with the safety concepts of IT / automation technology and are familiar
with them as project personnel
the persons are operators of the IT / automation systems and have been instructed in the use
of the systems and IT systems. They are familiar with the operation of the modules and
technologies described in this documentation
the persons are commissioning engineers or assigned for service and have completed training
that qualifies them to repair IT / automation systems. They are also authorised to commission,
earth and label circuits and equipment in accordance with safety engineering standards. During
use, the legal and safety regulations required for the respective application must also be
observed. This also applies to the use of accessories. Maintenance and repair work on the open,
live unit may only be carried out by a trained person who is aware of the danger involved

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
8
von
27
User Manual V
-
180131
-
BHA00
1.11 Symbols and Meanings
Symbol:
Meaning: Connection for grounding
the connection must be at protective earth potential.
Symbol:
Meaning: CE-Marking
With the CE marking, the manufacturer guarantees that his product complies with the requirements
of the relevant EC directives.
Symbol:
Meaning: ESD (Electrostatically Sensitive Devices)
To ensure protection of sensitive electronic components against electrostatic discharge, precautions
must be taken, such as suitable work clothing, dissipative floor coverings, a grounding strap, etc.
Symbol:
Meaning: Federal Communications Commission
The device has been subjected to expert certification by a recognized test laboratory. With the FCC
marking, the manufacturer guarantees that its product complies with the requirements of the
relevant FCC guidelines.
Symbol:
Meaning: Warning: Risk of electric shock
Danger from touching electrically conductive components by direct and indirect contact.
Symbol:
Meaning: disconnect main plug(s) – power input
before opening the device, the main plug(s) must be disconnected, the device must be free of
voltage. Note: The system may only be opened by trained specialists.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
9
von
27
User Manual V
-
180131
-
BHA00
2 Assembly SDoT-Server V3B
The SDoT Server V3B is a 19" unit for use in server racks. Suspension bolts on the rear and eyelets on
the front are used for mounting in 19" racks. Alternatively, mounting rails can be used to allow the
unit to be pulled out of an IT cabinet for operation.
The SDoT Server V3B 10G SC variant shown below has a smartcard slot and two 10 Gbit network
ports (N5, N6).
Optional variants of the SDoT Server V3B are available:
Variant: SDoT Server V3B 10G has two 10 Gbit network ports (N5, N6).
Variant: SDoT Server V3B SC has a smartcard slot.
Variant: SDoT Server V3B HSM has a hardware security module (HSM) that is permanently integrated
in the housing. There is a battery compartment on the back, which contains a battery as an
emergency power source for this variant.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
10
von
27
User Manual V
-
180131
-
BHA00
3 Connection SDoT-Server V3B
The AC power supply should be located close to the device and easily accessible, as this serves as a
disconnecting device for the device. Alternatively, electronic components can be installed to ensure
that the system is de-energised when actuated.
Connect the two marked IEC plugs - redundant power supply unit

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
11
von
27
User Manual V
-
180131
-
BHA00
If a power unit is defective, you can replace the power unit.
1. switch off the SDoT Server V3B and remove it from the power supply
2. pull the plug out of the defective power supply unit
3. press the black locking lever in the direction of the bow handle
4. while holding the lever, pull the power supply out of the housing by the metal bracket
5. check that the replacement power supply corresponds to the required type
Manufacturer: 3Y Power Technology
Model: YM-2301E
Power: 300 W
Input: 0-240 V AC, 3.0-5.0 A, 50-60 Hz
Output: +12 V DC, 24 A; Standby: +5 V, 3 A
6. hold the new power supply with the label facing up and the metal bracket facing back
7. slide the new power supply into the free slot until the power supply is fully engaged
8. plug the connector back into the power supply

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
12
von
27
User Manual V
-
180131
-
BHA00
3.1 Server Front Side
H1 – Insertion compartment for the audit removable hard drive
N1 – Network connection to HIGH interface, up to 1 Gbit
N2 – Network connection to LOW interface, up to 1 Gbit
N3 – Mains connection to HEARTBEAT interface
N4 – Network connection to ADMIN interface
N5 – Network connection to HIGH interface, up to 10 Gbit
N6 – Network connection to LOW interface, up to 10 Gbit
P1 - On/off pressure switch
U1 - USB1 for keyboard
U2 - USB1 for keyboard
V1 – DisplayPort for display, possibly via adapter
R1 – Reset switch, to be operated with paper clip
S1 – RS232 connection
T1 – LC Touch display

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
13
von
27
User Manual V
-
180131
-
BHA00
3.2 Server Rear Side
The rear of the SDoT Server V3B has a battery compartment and two power supply units, the slide-in
bolts and the openings for the fan module.
1
2
3
Insertion bolt in 19“-Rack
Battery compartment
Fan module
4
5
6
Mass fan module
Power supplies
Manufacturer´s device label
3.3 Main Power Supply
230 V-AC Input voltage, wide range input 90 ... 264 V-AC
connector plug: 2 x cold appliance connector plug, incl. cable 2m, with lock
the power supply for all onboard components is generated according to the required power
data on the mainboard.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
14
von
27
User Manual V
-
180131
-
BHA00
3.4 Ground Connection
Grounding/potential equalization of the device is mandatory. For this purpose, a grounding screw is
provided on the front and marked with the grounding symbol
3.5 Interface USB3.0 – U1 & U2
For maintenance purposes only. These interfaces can be used to connect devices such as keyboard,
mouse, printer or data storage devices such as USB sticks.
3.6 Network Interface (Ethernet & Mini Gigabit Interface) - N1 to N6
Six network interfaces (N1 - N6) are available. Of these, two network interfaces (N5 - N6) are optional.
3.7 Serial Interface RS232 – S1
A maintenance console, for example, can be connected via RS232. The interface does not provide a
power supply.
3.8 Display-Port – V1
Interface for connecting a monitor

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
15
von
27
User Manual V
-
180131
-
BHA00
3.9 LC Touch-Display Modul – T1
Grayscale LC display with a resistive touch
3.10 Reset-Button - R1
System reset button
3.11 Power on - Push-Button with LED - P1
The device is switched on via the P1 button. The integrated LED lights up green when the system is
powered on.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
16
von
27
User Manual V
-
180131
-
BHA00
4 Operating SDoT Server V3B
4.1 Replacing the Audit-Hard Disk – H1
The SDoT Servers V3B has an audit hard disk that is installed in the form of a removable hard disk.
This removable hard disk can be replaced.
For information on the status and changing of the audit hard disk, refer to the user manual of the
SDoT Product.
Follow the steps below to securely change the audit disk
1. log in to the SDoT Server V3B as an auditor
2. open Status Audit system
3. click on System » Change HDD
the entry next to the third diode indicates a change
4. confirm the security prompt with Change HDD
the SDoT product switches to maintenance mode
the removable hard drive status indicator on the dashboard changes from red to blue
a note is displayed on the screen that the audit hard disk is enabled
5. remove the removable hard disk and replace it with an empty disk
6. lock the slide-in module again
The SDoT product sets up the new hard drive as audit storage. The SDoT product independently
switches to operational mode.
Keep the data carrier in a safe place and ensure that the stored data is handled in accordance with
security requirements.

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
17
von
27
User Manual V
-
180131
-
BHA00
4.2 Starting the SDoT Server V3B
After installing the SDoT Server V3B in a 19" IT cabinet and connecting it to the power supply using
the IEC cables, the device can be put into operation.
The basic steps for operating the SDoT Server V3B are described below. For detailed information,
refer to the manual for your SDoT product.
Put the SDoT Server V3B into operation:
1. press the on/off switch P1
2. follow the indication of the LC touch display T1
3. enter the four- or six-digit system PIN
PIN Entry on the LC Touch Display
a. press the arrow keys above and below each PIN field to select the character
b. as you type, the characters in this field are visible and remain so for a few seconds after
you type
c. the PIN may only contain alphanumeric characters, i.e. the numbers from 0 to 9 and the
capital letters from A to Z
4. press the checkmark key at the bottom right of the LC touch display to confirm the PIN entry
If you have entered an incorrect PIN, the display will show PIN incorrect.
After the third incorrect entry, the SDoT product locks the LC touch display

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
18
von
27
User Manual V
-
180131
-
BHA00
5. the LC touch display shows the ident string
a. check whether the ident string is unchanged and confirm this within 30 seconds with
the checkmark key at the bottom right of the LC touch display
6. the LC touch display shows the start screen of the SDoT Product
Startup Display of the SDoT Product (exemplary)
The following describes the meaning of the symbols used on the LC touch display.
4.3 LC-Touchdisplay – T1
After the SDoT Server V3B has booted up successfully, the LC touch display shows the operating
status and allows information to be queried.
1
2
3
Operating status (OK)
HSM or SC status (OK)
HA operation (not available)
4
5
6
7
Up and down keys guide through the display 5
Display range for 6 and 7
Activate the information for 1, 2 and 3
Activating the menus
Menu display on the LC touch display (exemplary)

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
19
von
27
User Manual V
-
180131
-
BHA00
1. In the left column, the LC touch display shows the status of (1) Operation, (2) Hardware
Security Module (HSM) or Smartcard (SC) and (3) High Availability (HA) mode.
The following table describes the individual symbols of these three statuses.
Display symbols for operation, HSM/SC and HA
No Display Symbol Description
1 Operating
status
Cross Boot up
Circle Maintenance mode
Checkmark Operational mode
2 Status
hardware
security module
or smartcard
Cross Incorrect
Checkmark All right
3 HA status Dotted square Not set up
Checkmark Active and master
Circle Active and slave
2. Click on the i button (6) at the top right to display more information about the operating mode
in the display area (5)
3. Click on the menu button with the three horizontal lines (7) at the bottom right to display the
menus in the display area (5)
4. Use the arrow keys to the left of the menu items (4) to move the menus up and down

iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 | USt-IdNr: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite
20
von
27
User Manual V
-
180131
-
BHA00
5. Tap a menu item with your finger to display the settings
System name
IP addresses
System date and system clock time
Version information
4.4 Shutdown and Restart
You can use the LC touch display to both shut down and restart the SDoT Server V3B.
1. click on the menu button with the three horizontal lines (7) at the bottom right to display the
menus
2. move the menu items with the arrow keys (5) downwards to the menu item Reboot /
Shutdown system
3. the LC touch display shows Reboot system and Shutdown system for selection
Selection on the LC Touch Display
a. press Reboot system to restart the SDoT Server V3B
b. press Shutdown system to turn off the SDoT Server V3B
4. confirm the operation by pressing the checkmark button again
This manual suits for next models
4
Table of contents
Popular Server manuals by other brands

Lenovo
Lenovo ThinkServer RS110 Hardware Maintenance Manual

EMC
EMC SVR-I2U-H2316 Installation and maintenance guide

Fujitsu
Fujitsu BS2000 SE Series operating manual

Dell
Dell PowerEdge C8000XD Hardware owner's manual

Sun Microsystems
Sun Microsystems SUN FIRE 280R Product notes

IBM
IBM 7944E1U Brochure & specs