OWNERS MANUAL
Smoke Alarm
/
EN
14604: 2005 Tested
(E:
Meets European Standards
iHudyat Contacts and Hotline:
Tel: +63 2 938 3653
Email: [email protected]
www.hudyat.colll
iHudyat Inc. (311 Ifbgao St., Saint
Dominic
Subd
,
Deparo Road,
Caloocan City, Phils)
Mode
l Number: HYSOO1
Batch Number:
P03001
/2
SMOKE ALARMS SAVE LIVES!
Meets
European Standards
PLEASE
KEEP
THIS
MANUAL
IN
A
SAFE
PLACE
1. PRODUCT fEATURES
Model number HYS001
Photoelectric smoke detector
and
alarm
Tested against
EN
14064 standards
Test button for recommended weekly check
Loud alarm (85d8)
Light flash alarm indicator
Low battery audio warning
Includes 9V battery
Includes fixings
2. GENERAL DOMESTIC SAFETY ADVICE
Installing smoke alarms
is
one part of being safe from
the risk offire
in
your home. Other steps you should take
include:
• Remove hazards that might start a fire from your home
• Plan
an
escape route
in
the event of fire and inform
everyone
in
your family
• Perform a check prior
to
going
to
bed
of any hazards
(e.g. candles or electrical equipment)
•
In
the event of fire leave the building
as
quickly
as
possible.
Do
NOT stop
to
collect anything.
You
and your
family should get outside
and
call the fire service.
•
Do
not re-enter a burning building.
3. WHERE TO LOCATE SMOKE ALARMS
Smoke alarms should
be
fitted near each sleeping area,
in
the bedroom itself
and
in
the hallway outside. One
smoke alarm gives your home a minimum protection.
Installing more smoke alarms provides better protection.
Smoke alarms should not
be
located
in
kitchens, bath-
rooms or garages, where normal activities may cause
false alarms. Smoke alarms should not
be
located near
air vents or heating vents,
as
these may stop smoke
reaching the alarm.
This product
is
only suited to single-occupancy dwell-
ings of three floors or fewer. For more information seek
manufacturer's advice.
Install the fire alarm
in
the middle of the ceiling. If you
cannot install
in
the middle of the ceiling place
on
the
ceiling at least 10cm from the wall, or
on
the wall at
least 15cm from the ceiling.
When the wall or ceiling
is
slanting install at least 1m
below the highest point
of
the wall or ceiling.
Large rooms over 10m
in
length may require more than
one smoke alarm.
•
D
LivingRoom
[D
o
~
D
Porch
Floor Plan Smoke Alarm •
4. INSTALLATION INSTRUCTIONS
a)
Turn the alarm body counter-clockwise
and
take off
the bottom plate.
b)
Press the bottom plate onto the wall or ceiling where
it
will
be
installed, mark the holes
of
the plate with
pencil.
c)
Remove the plate and bore two holes with
an
electric
drill where marked with pencil.
d)
Sink the plastic wall plugs into the holes with
hammer.
e)
Press the bottom plate onto the wall or ceiling
in
the
same position
as
before, insert the screws through the
holes
in
the plate and into the wall plugs, tighten the
screws.
f)
Connect the battery
to
the terminals inside the smoke
alarm and insert the battery into the battery box.
g) Attach the alarm body to the bottom plate
by
turning
clockwise until
it
clicks
in
place.
WARNING:
To
avoid injury or malfunction the smoke
alarm should
be
securely attached to the wall or ceiling
in
accordance with the above instructions.
5.
HOW
TO TEST
The detection and alarm functions of this smoke alarm
can
be
tested by pressing the button
in
the middle. After
holding the button for a few seconds the alarm will sound.
If the alarm does not sound please check the battery
is
charged and properly connected.
It
is
not necessary or safe
to
test the smoke alarm
by
creating smoke, such
as
by
using a cigarette. The proper
functioning of the smoke alarm
is
tested using the button
as described above.
6. MAINTENANCE
Do
not attempt repair of this smoke alarm. Test regularly
according
to
the instructions above. Clean around and
within the smoke alarm using a vacuum cleaner to
remove dust or insects that could affect the smoke alarm's
correct operation.
If the battery
is
low the smoke alarm will beep intermittent-
ly.
The smoke alarm will not work without adequate
battery power. If you hear the low battery warning please
replace the battery immediately.
7. LIMITATIONS OF SMOKE ALARMS
WARNING: This smoke alarm
is
not meant to
be
used
in
non-residential buildings. Warehouses, industrial or com-
mercial buildings,
and
special purpose non-residential
buildings require special fire detection and alarm
systems. This smoke alarm alone
is
not a suitable substi-
tute for complete fire detection systems for places where
many people live or work, such as hotels or motels. The
same
is
true of dormitories, hospitals, nursing homes or
group homes of any kind, even if they were once single
family homes.
A smoke alarm does not work without power, so you
should attend
to
any low battery warning promptly
as
well
as testing regularly using the test button.
A smoke alarm only works if smoke reaches it (this may
be
prevented by closed doors
in
your house, incorrect
installation of the smoke alarm or insufficient cleaning of
the smoke alarm)
A smoke alarm
is
only part of a home fire safety
programme and does not protect against risks such as
gas explosion.
The maximum life of this smoke alarm if well main-
tained
is
10
years, after which it should be replaced.
Warranty
iHudyat Inc. warrants this product against defects
in
manufacture and
wo
rkmanship for a period
of
3
years afterpurchase.
If
the product proves defective during this warranty
period, iHudyat Inc., atits option, will eitherrepair the
defective product without charge for parts
and
labo
r,
or
will provide a replacement
in
exchange for the
defective product. Batteries are excluded from this
warranty
In
order to obtain service under this warranty, the
customer must notify iHudyat Inc.
of
the defect
before the expiration
of
the warranty period. The
customer shall be responsible
fo
r packaging and
shipping the defective product
to
the address desig-
nated
by
iHudyat Inc. The customershall be respon-
sible for paying all duties, taxes,
and
any other
charges required
in
order to ship the product.
This warranty shall not apply
to
any
defect, failure
or
damage caused
by
improper use
or
improper
or
inadequate maintenance and care.
This warrantyis given
by
iHudyat Inc. with respect to
the productin lieu
of
anyotherwarranties, express
or
implied. iHudyat Inc. disclaims
any
implied warran-
ties
of
merchantability
or
fitness for a particular
purpose and will not be liable for
any
indirect,
special, incidental,
or
consequential damages for
breach
of
this warranty iHudyat
Inc.
's responsibility
to
repair
or
replace defective products is the sale and
exclusive remedy provided
to
the customer for
breach
of
this warranty.
iHudyat Contacts
and
Hotline:
Tel
: +63 2 938 3653
Email: [email protected]
www.hudyat.com
iHudyat
Inc.
311
Ifugao Street
Saint Dominic Subdivision
Deparo Road
Caloocan City
Philippines
EN 14604: 2005 Tested
(E
Meets European Standards

Popular Smoke Alarm manuals by other brands

Geofire Agrippa User instructions

Geofire

Geofire Agrippa User instructions

Lifesaver i9040EU user guide

Lifesaver

Lifesaver i9040EU user guide

LST OP-12001 Specification sheet

LST

LST OP-12001 Specification sheet

System Sensor FAAST LT-200 FL20 Series Quick installation guide

System Sensor

System Sensor FAAST LT-200 FL20 Series Quick installation guide

American Sensor SA379 manual 

American Sensor

American Sensor SA379 manual 

Kidde 3050-VDSC10 user guide

Kidde

Kidde 3050-VDSC10 user guide

Kidde 1296 user guide

Kidde

Kidde 1296 user guide

Numens SNA-360 installation instructions

Numens

Numens SNA-360 installation instructions

U-Prox Smoke quick start guide

U-Prox

U-Prox Smoke quick start guide

BRK electronic 7010BA Specification sheet

BRK electronic

BRK electronic 7010BA Specification sheet

Lince ZENITH GOLD 869 Series Installation, Programming and Operating Instructions

Lince

Lince ZENITH GOLD 869 Series Installation, Programming and Operating Instructions

Essence Security ES700SK2 Installation

Essence Security

Essence Security ES700SK2 Installation

DSC Meridian WLS906-433 Instructions for installation and use

DSC

DSC Meridian WLS906-433 Instructions for installation and use

LEGRAND tynetec ZXT810 quick start guide

LEGRAND

LEGRAND tynetec ZXT810 quick start guide

Fireray 3000 user guide

Fireray

Fireray 3000 user guide

BRK electronic SA340B quick start guide

BRK electronic

BRK electronic SA340B quick start guide

VESDA LaserCOMPACT Product guide

VESDA

VESDA LaserCOMPACT Product guide

BRK electronic 4000LB Specification sheet

BRK electronic

BRK electronic 4000LB Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.