General safety instructions
JRead this entire user manual carefully before plugging in the unit.
JKeep these instructions to hand during unit installation.
JFollow all the instructions and safety notices when handling the uni
DANGER OF DEATH OR INJURY
JThis safety notice indicates a potential hazard to people’s lives and/or health. Failure to follow these instructions can lead to severe
health consequences and may even cause fatal injuries.
JDo not install the unit during electrical storms. This could lead to electro-static discharge from lightning.
JDo not open the unit. You may suffer an electric shock.
RISK OF DAMAGE TO THE UNIT
JThis safety notice indicates a potentially hazardous situation. Failure to follow these instructions may cause material damage to the unit.
JKeep the unit well-ventilated at all times. Install the unit in an area free of dust. Do not place the unit in a place where the ventilation
slots may become blocked or obstructed.
Leave a distance of at least 20 cm all around the unit’s sides. We recommend installing the unit in the VERTICAL position.
JDo not expose the unit to rain or moisture. Install in a dry location where potential leaks or condensation will not occur. In the event that
liquid gets into the device, disconnect it immediately from the alternating current.
JKeep ammable objects, candles and anything that may cause a re away from the unit.
JConnect the unit to an easily-accessible mains outlet, so that the unit can be quickly disconnected from the outlet in case of emergency.
JDo not expose the unit to sources of heat (sunlight, radiators, etc).
DO NOT HANDLE ANY OF THE UNIT’S INTERNAL PARTS
This notice indicates that users should not handle any internal parts that could affect its working order or warranty.
DO NOT DISPOSE OF UNIT AS NORMAL DOMESTIC URBAN WASTE
This type of notice indicates that the unit should not be disposed of as unselected domestic urban waste.
DANGER
ATTENTION
Product installation
LOCATION
JLocate the multiswitch indoors. Do not expose it to rain and direct solar radiation. Fix it to the wall by using suitable screws.
JEnsure a free space of 20 cm (7.8 inch) on each side of the unit, upwards a clearance at least 50 cm (19.7 inch).
JChoose an installation place where there is a possibility in case of emergency to get to mains plug and remove it out of the outlet.
SAFETY
JDo not open the multiswitch; otherwise there is a shock hazard.
JBe sure with sufcient earthing of the aerials and aerial feeds.
CONNECTON
JTake care not to make short-circuits when mounting the F-connectors on the cables.
JIdentify the down-lead cables from the LNB. Then interconnect the input marked 12V to the LNB output Vertical. Interconnect the input marked
18V to the LNB output Hori-zontal. Interconnect the input marked 0kHz to the LNB output Low. Interconnect the input marked 22kHz to the LNB
output High.
JBefore connecting the input and output coaxial cables, disconnect from the mains the multiswitch as well as the receivers and TV sets.
JNot connected outputs of the multiswitch should be terminated with 75Ω terminations..
JInput signal levels may be levelled with the existing variable attenuators. This work requires an appropriate SAT-TV analyzer.
JActive and passive mode of terrestrial band can be selected by the switchs or potentiometer. The return path is available in the passive mode.
The applicable European Standards and national requirements to ensure electrical security have to be obeyed. Likewise national standards and requi-
rements for radio and TV receiving installations.