Imagine communications Selenio VMG-14+ User manual

SelenioTMVMG‐14+
01‐Jun‐2015
RevisionA
HardwareSetupGuide

SelenioTM VMG-14+ Hardware Setup Guide 2
SelenioTM VMG-14+ Hardware Setup Guide
Document part number: 250-0350-01 Rev A
Printed 6/1/15
PublicationInformation
Copyright 2005-2015 Imagine Communications Corp. Proprietary and Confidential.
This material is protected by the copyright laws of the United States and other countries. No part of this document may be
reproduced, distributed, or altered in any form, by any means, by any entity nor may it be used to make any derivative work
(such as translation, transformation, or adaptation) except in accordance with applicable agreements, contracts, or
licensing, without the express written consent of Imagine Communications. All other uses are illegal.
Notice
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may
not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant
description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right,
without notice to make such changes in equipment, design, specifications, components, or documentation as progress may
warrant to improve the performance of the product.
Trademarks
SelenioTM and TelurioTM are trademarks of Imagine Communications. Microsoft® and Windows® are registered
trademarks of Microsoft Corporation. All other trademarks and trade names are the property of their respective companies.
Patents
The products described herein are covered by one or more U.S. and foreign patents pending.
U.S. Patents: 6,996,129; 7,046,677; 7,818,355; 8,180,920. Other US and foreign patents pending.
ContactInformation
Imagine Communications has office locations around the world. For domestic and international location and contact
information see: http://www.imaginecommunications.com/contact-us/
SupportContactInformation
For domestic and international support of Selenio VMG, Selenio BNP, Selenio SEP, Selenio MMC, Selenio TAT, Telurio
Packager, Telurio Recording Manager, and Telurio AIM products, contact:
http://www.rgbnetworks.com/support/rgb-customer-portal.php
1.877.RGB.NETW // (1.877.742.6389) - Inside North America
+1.408.701.2800 - Outside North America
For domestic and international support of all other Imagine Communications' products not mentioned above, contact:
Support Contacts: http://www.imaginecommunications.com/services/technical-support/

SelenioTM VMG-14+ Hardware Setup Guide 3
DocumentChangeHistory
SelenioTM VMG-14+ Hardware Setup Guide Document History
Part Number Software Version Release Date Changes
250-0350-01 Rev A N/A 06/01/2015 • Updated graphics and verbiage to Imagine
Communications branding
250-0248-01 Rev A N/A 12/19/13 • Recommended Ethernet cable routing
information, and doc maintenance.
• Updates to Initialization chapter, to incorporate
current Element Manager screens.
250-0211-01 Rev A N/A 6/15/13 • Add NPM2, TCM2, TCM2+
• Add new DC PEM Terminal Block Cover.
250-0177-01 Rev A Release 3.1.3 11/15/12 • Updated hardware: two fan trays.
• Correct numbering for SCMs and AC PSUs.
250-0137-01 Rev A Release 3.1 11/30/11 New Product

SelenioTM VMG-14+ Hardware Setup Guide 4
TableofContents
Publication Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Patents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Support Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Chapter 1: Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Document Organization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Document Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Chapter 2: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
In This Chapter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
VMG-14+ Chassis and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chassis Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chassis Rear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Basic Chassis Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Shelf Control Managers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Fan Filter Tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Network Processor Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
NPM and NPM2 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
NPM and NPM2 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
NPM and NPM2 Management and Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
VMG-14+ System Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Video Processor Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Transcoding Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Application Media Processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
System Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
AC System Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
DC System Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Cable Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Filler Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Chapter 3: Physical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
In This Chapter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Tools and Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

SelenioTM VMG-14+ Hardware Setup Guide 5
Gen2 Release 1.4.0
Site Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Site Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Rack Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Rack Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Power Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Electrostatic Discharge (ESD) Prevention. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Inspect Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Verify Receipt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Use ESD Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Installing the Chassis at the Operations Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Inserting VMG Modules—New System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Preparing the Power Supply (For DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Preparing the Power Supply (for AC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Loading the Application Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
AMP-to-NPM Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Double-Checking the Physical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Power Up and Verify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
System Initialization Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Required equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Chapter 4: Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
In This Chapter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Selenio VMG Physical and Virtual IP Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Using TCON (Temporary Console) to Set Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . 53
The TCON Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Viewing Current Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Setting Network Addresses for the NPM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Verifying Gateway Connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Viewing VMG Build Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Using Element Manager to Finalize Initial Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Chapter 5: Troubleshooting and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
In This Chapter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Hot Swap Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Handling Application Modules-Live System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Removing VMG Modules from a Live System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Replacing VMG Modules at a Live System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
DC Power Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
AC PSU Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Shelf Control Manager Servicing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
SCM Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
SCM Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fan Tray Servicing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fan Tray Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fan Tray Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

SelenioTM VMG-14+ Hardware Setup Guide 6
Gen2 Release 1.4.0
Fan Filter Tray Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Fan Filter Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Fan Filter Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
FRU Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
If You Need Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Imagine Communications Technical Response Center. . . . . . . . . . . . . . . . . . . . . . . . . . 66
Imagine Communications Customer Portal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Event Log Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Chapter 6: System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
In This Chapter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Application Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Input / Output Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Weight Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Environmental Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Appendix A: Localized Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
In This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Appendix A: Conformity and Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Declarations of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
United States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Europe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Australia/New Zealand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

SelenioTM VMG-14+ Hardware Setup Guide 7
ListofFigures
Figure 1: VMG-14+ Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 2: VMG-14+ DC System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 3: VMG-14+ AC System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 4: VMG-14+ Front—AC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 5: VMG-14+ Front—DC System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 6: VMG-14+ Rear —AC System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 7: VMG-14+ Rear —DC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 8: Shelf Control Manager Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 9: Fan Trays and Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 10: Fan Tray LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 11: VMG-14+ Fan Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 12: NPM Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 13: NPM2 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 14: VPM Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 15: TCM, TCM2, TCM2+ Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 16: AMP Module Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 17: AC PSUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 18: AC PSU Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 19: AC PEMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 20: DC PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 21: DC PEM Terminal Block Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 22: Cable Management Bracket (closed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 23: Cable Management Bracket (open) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 24: Managing Ethernet Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 25: Location of ESD Jack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 26: Card insertion—alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 27: Chassis (rear) Ground and Logic Ground—DC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 28: DC PEM Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 29: Chassis Ground and Logic Ground—AC Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 30: AC Power Supply Unit: Ejector/Insertion Lever (Open) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 31: AC Power Supply Unit: Ejector/Insertion Lever (Close) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 32: AC Power Entry Modules with Imagine Communications-Supplied Cords . . . . . . . . . . . . . . . 46
Figure 33: NPM or NPM2 Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 34: AMP Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 35: AMP Connections to an NPM or NPM2 Pair in the VMG-14+ . . . . . . . . . . . . . . . . . . . . . . . . . 49
Figure 36: VPM and TCM Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 37: Selenio VMG Home Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 38: VMG Element Manager Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 39: Element Manager - Chassis View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 40: Accessing System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 41: Global Configuration - Management Interface Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 42: Module (generic) ejector handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 43: AC PSU for VMG-14+ AC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 44: AC Power Entry Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 45: Fan Tray Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 46: Imagine Communications Customer Portal home page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 47: Customer Portal home page - Direct and Reseller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 48: Knowledge Base search - Direct and Reseller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

SelenioTM VMG-14+ Hardware Setup Guide 8
ListofTables
Table 1: Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2: Contact Information for Product Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 3: VMG-14+ Chassis Modules and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 4: Shelf Control Manager—Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 5: RJ-45 Port Pinouts—VMG-14+ SCM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 6: Fan Tray LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 7: NPM Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 8: NPM Front Panel LED Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 9: NPM Serial Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10: VMG-14+ System Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 11: VPM Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12: TCM, TCM2, TCM2+ Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 13: AMP Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 14: AC Power Supply LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 15: DC PEM LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 16: DC Ground Connection Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 17: DC Power Connection Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 18: Hot Swap LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 19: Hot Swap LED Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 20: FRU Reference for VMG-14+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 21: Application Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 22: Input/Output interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 23: System and Component-Level Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 24: Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 25: Safety Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Table 26: Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 27: Weight Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 28: DC Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 29: AC Power Input Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 30: AC Power Supply Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 31: Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 32: EN55024 Referenced Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Table 33: EN550-22 Referenced Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 34: VCCI Referenced Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

SelenioTM VMG-14+ Hardware Setup Guide 9
CHAPTER 1
Introduction
All SelenioTM Video Multiprocessing Gateway (VMG) systems from Imagine Communications deliver the
industry's highest density digital video solution—per Rack Unit (RU)—for grooming, statistical
multiplexing, transrating, digital program insertion (DPI), and MPEG-2 / H.264 transcoding. Based on a
flexible, scalable and modular platform, VMG systems expedite deployments of advanced video
services and simplify operation and management, while reducing operational and capital costs.
The SelenioTM VMG-14+ is available as a DC-powered (13 RU) or an AC-powered (14 RU) system, and
both are front-loading systems for use in standard Telco racks.
This SelenioTM VMG-14+ Hardware Setup Guide describes the Selenio VMG system hardware and
provides guidelines for physical installation, initial configuration, and basic troubleshooting.
DocumentOrganization
This guide is organized as follows:
•Chapter 1, Introduction – (this chapter) describes the contents and conventions used in the
SelenioTM VMG-14+ Hardware Setup Guide.
•Chapter 2, Overview – provides a detailed description of the VMG-14+ features and components.
•Chapter 3, Physical Installation – describes the initial steps and requirements for installing the
VMG-14+.
•Chapter 4, Initial Configuration – describes how to prepare a GEN1 system (VMG-14+ populated
with one or more NPM cards) for management by the VMG Element Manager.
•Chapter 5, Troubleshooting and Maintenance – provides information about LED indicators and
component replacement.
•Chapter 6, System Specifications – includes information about regulatory, environmental, electrical,
and mechanical compliances.
•Appendix A, Localized Cautions and Warnings – lists all of this guide’s Caution and Warning
statements in French and German.
•Appendix A, Conformity and Safety Information – provides regulatory compliance information for
the Selenio VMG.
•The glossary and index can be used to quickly reference information.
DocumentAudience
This guide is intended for system administrators who are responsible for installation and maintenance
of the Selenio VMG at Telco and Cable Headends. Users of this guide should be familiar with general
video and networking terminology and should be accustomed to basic network hardware installation.
Most importantly, the user must be familiar with the basics and principles of broadcast network
processing.

SelenioTM VMG-14+ Hardware Setup Guide 10
Related Documentation Gen2 Release 1.4.0
RelatedDocumentation
•Video Multiprocessing Gateway, Element Manager User Guide.
•Video Multiprocessing Gateway, Software Upgrade Guide.
•Video Multiprocessing Gateway Software Release Notes.
•Application Media Processor (AMP) Install Guide for GEN1 VMG Systems.
DocumentConventions
Tabl e 1 provides an easy way to recognize information of particular importance in this manual
Table 1. Document Conventions
When
you see: It means:
Notes point out information that may not be part of the text but provide tips and other helpful
advice.
Cautions let you know that an action may have undesirable consequences if the instructions are
not followed correctly. Cautions also indicate that failure to follow guidelines could cause damage
to equipment or loss of data.
Les symboles "ATTENTION", représentés par l'icône de gauche, indiquent qu'une action peut
avoir des conséquences indésirables si les instructions ne sont pas suivies correctement.
Les symboles " ATTENTION " indiquent également que le fait de ne pas suivre les instructions
peut causer des dommages à l'équipement ou résulter en une perte de données.
Das links abgebildete Symbol Vorsicht weist darauf hin, dass ein Vorgang unerwünschte
Konsequenzen haben kann, falls die Anweisungen nicht korrekt befolgt werden.
Das Symbol Vorsicht weist außerdem darauf hin, dass Geräte beschädigt oder Daten verloren
gehen können, wenn die Anweisungen nicht befolgt werden.
Warnings indicate that failure to take the necessary precautions or to follow guidelines could
cause harm to equipment and personnel.
Les symboles " AVERTISSEMENT ", représentés par l'icône de gauche, indiquent que le fait
de ne pas prendre les précautions nécessaires ou de ne pas suivre les instructions peut
endommager l'équipement ou provoquer des blessures.
Das links abgebildete Symbol Warnung weist darauf hin, dass Geräte beschädigt oder
Personen verletzt werden können, wenn die notwendigen Vorsichtsmaßnahmen nicht
eingehalten oder die Anweisungen nicht befolgt werden.
Hyperlinks: Clicking any blue link takes you to the item to which the link refers.
Localization: See Appendix , “Localized Cautions and Warnings” for the French and German versions of the
caution and warning statements in this manual.

SelenioTM VMG-14+ Hardware Setup Guide 11
Graphics Gen2 Release 1.4.0
Graphics
In some cases the line art and screen-shots shown in this manual may differ slightly from what appears
on the actual product.
All efforts have been made to ensure that the latest images are used. In all cases, the functionality
described is current at the time of writing.
TechnicalAssistance
Use the contact information provided in this section if you need to phone or write to Imagine
Communications Customer Support for assistance with VMG installation, initial configuration, or other
VMG product issues.
See also the RBG Networks web site at http://www.rgbnetworks.com/support for more details.
Table 2. Contact Information for Product Returns
To Do This... Use this contact information
Return product.
Request authorization from
Imagine Communications to
return materials
Customer Portal: http://support.rgbnetworks.com
Phone
From inside USA:
From outside USA:
1.877.RGB.NETW
(977.742.6389)+1.408.701.2800
Email [email protected]
Affix proper address on the
return shipment
Company Address
RMA Number
Use address and RMA number, as advised by
your Imagine Communications Customer
Support contact.

SelenioTM VMG-14+ Hardware Setup Guide 12
CHAPTER 2
Overview
The Imagine Communications Video Multiprocessing Gateway (VMG) products provide stream routing,
switching and video processing for deployment of digital simulcast, digital broadcast and IPTV
streaming in advanced digital cable TV and Telco IPTV networks.
The 14-slot (300-watt) Video Multiprocessing Gateway “Plus” system (VMG-14+) from Imagine
Communications is provides high-level carrier-class service availability through the chassis, service-
level, and module-level redundancy and is engineered for future-proof operations. It is ideally suited
for operations at lower density video headends and hub sizes, to deliver the industry’s highest density
digital video solution per-rack-unit for grooming, statistical multiplexing, and digital program insertion
(DPI), and transcoding.
The VMG-14+ is fully MPEG-2 and H.264 compliant and interoperable with leading video industry
equipment; it shares the same software functionality and application modules (NPMs, AMPs, TCMs,
and VPMs) as all other VMG systems. This chassis is available either as an AC or DC system (Figure 1)
and all system modules and shelf management modules are conveniently loaded at the front of the
chassis cage.VMG-14+ chassis slots support up to 300 watts each, to enable seamless migration to
future high capacity modules. The VMG-14+ provides advanced standard definition (SD) and high
definition (HD) MPEG-2 and MPEG-4/H.264 video processing, which enables telecommunications
deployment of next-generation cable and IPTV services.
Figure 1. VMG-14+ Chassis
VMG-14+ AC System VMG-14+ DC System

SelenioTM VMG-14+ Hardware Setup Guide 13
In This Chapter: Gen2 Release 1.4.0
InThisChapter:
•“Product Features,” next.
•“VMG-14+ Chassis and Components” on page 14.
•“Network Processor Modules” on page 23.
•“VMG-14+ System Modules” on page 26.
•“System Power” on page 30.
•“Cable Management” on page 33.
•“Filler Panels” on page 34.
ProductFeatures
In addition to being software-upgradeable, scalable and reliable, the VMG-14+ platform has the
following features:
•Up to 300 watts per slot.
•Web-based embedded management.
•Front-loading, hot-swappable Video Processor Modules (VPMs), Transcoding Modules (TCM,
TCM2, TCM2+), Network Processor Modules (NPM or NPM2), Application Media Processors
(AMPs), and (two) fan trays.
•Redundancy:
-Intelligent Platform Management Bus (IPMB) interfaces in a radial configuration.
-1:1 Shelf Control Manager (SCM), 1:1 NPM or NPM2 (and AMP) redundancy, N+M VPM and
TCM redundancy, and service-level redundancy.
-Redundant Power Entry Modules (PEMs).
•Mounting flanges for 19” cabinets.
•Chassis size:
-AC system = 14 RU
-DC system = 13 RU
•14 front-loading slots: Two dedicated for NPM or NPM2 insertions.

SelenioTM VMG-14+ Hardware Setup Guide 14
VMG-14+ Chassis and Components Gen2 Release 1.4.0
VMG‐14+ChassisandComponents
The VMG-14+ utilizes a chassis platform fitted either for 13 RU (DC system) or 14 RU (AC system). The
front of the VMG-14+ chassis cage accommodates all system and application modules. For AC systems
(Figure 3), the front also includes the AC PSUs located in the power bay at the base of the system.
Figure 2. VMG-14+ DC System
Figure 3. VMG-14+ AC System
FRONT
13 RU
REAR
19”
21”
FRONT REAR
14 RU
20” 19”

SelenioTM VMG-14+ Hardware Setup Guide 15
VMG-14+ Chassis and Components Gen2 Release 1.4.0
ChassisFront
The VMG-14+ chassis cage front provides 14 vertical slots for loading of the application modules. Two
of these slots are dedicated for use by Network Processor Modules (NPM or NPM2) for 1:1 redundancy
configuration.
•If the VMG-14+ is using GEN2 NPM2 cards, the remaining 12 slots can be used for Transcoding
Modules (TCM2, or TCM2+).
•If the VMG-14+ is using GEN1 NPM cards, the remaining 12 slots can be used for Video Processor
Modules (VPM), Transcoding Modules (TCM), and up to two Application Media Processors (AMPs).
Note: Rules for loading the various modules are applicable. See “Basic Chassis Populations” on page 18
for more information.
System modules fit into numbered slots, from left (1) to right (14). Up to two Shelf Manager modules
fit into the two vertical slots at the left edge of the chassis, alongside slot 1. The AC (Figure 4) and DC
(Figure 5) VMG chassis are identical except for the inclusion of AC PSUs at the base of the AC chassis.
For slot assignments, see Tab le 3.
Rack-mounting flanges are incorporated into the chassis at the left and right front edges, to enable
front-mount at the rack. During installation, you will prepare the rack by attaching a chassis shelf to it,
which will support the rear of the rack-mounted chassis.
Figure 4. VMG-14+ Front—AC System
Power Bay: AC PSUs
Air Intake Grid
Fan Trays
Fan Filter Tray
Cable Management
Bracket
Card Cage:
Slots 1 through 14
ESD Jack
Shelf Control Modules
SCM 2
SCM 1
PSU 4 PSU 3 PSU 2 PSU 1

SelenioTM VMG-14+ Hardware Setup Guide 16
VMG-14+ Chassis and Components Gen2 Release 1.4.0
Figure 5. VMG-14+ Front—DC System
Air Intake Grid
Fan Trays
Fan Filter Tray
Cable Management
Bracket
Card Cage:
Slots 1 through 14
ESD Jack
Shelf Control Modules
SCM 2
SCM 1

SelenioTM VMG-14+ Hardware Setup Guide 17
VMG-14+ Chassis and Components Gen2 Release 1.4.0
ChassisRear
The rear chassis cage contains the power entry modules at the base of the system. All slots at the rear
card cage are covered with RTMs. These must not be removed.
Figure 6. VMG-14+ Rear —AC System
Figure 7. VMG-14+ Rear —DC System
Card Cage:
Slots 1 through 14
for RTMs
ESD Jack
Air Intake Grid
Power Bay:
AC PEMs
Chassis GND
Card Cage:
Slots 1 through 14
for RTMs
ESD Jack
Power Bay:
DC PEMs
Chassis GND

SelenioTM VMG-14+ Hardware Setup Guide 18
VMG-14+ Chassis and Components Gen2 Release 1.4.0
BasicChassisPopulations
Slot assignments determine where to load the system modules, SCMs, fan trays, air filter, and (for AC)
power supply units. The VMG-14+ supports the components and modules listed in Table 3.
:
Table 3. VMG-14+ Chassis Modules and Components
Name Description System
Capacity Slot Assignments
Network Control
Processor (NPM and
NPM2)
Either NPM type provides management
functions and ingress/egress for transport
streams.
The NPM2 also provides packet inspection.
Compatibility Notes:
• The NPM is compatible with the TCM
card.
• The NPM2 is compatible with TCM2 or
TCM2+ cards.
• Various models of NPM cards cannot be
mixed. Use only NPM or only NPM2 cards
in your VMG-14+.
See also “Network Processor Modules” on
page 23.
•NPM:2
or
•NPM2:2
Front,
slots 1 and 2.
System modules Family of modules that includes AMP, TCM,
TCM2, TCM2+, and VPM.
Compatibility Notes:
• The TCM, AMP, and VPM is compatible
with NPM.
• The TCM2 or TCM2+ is compatible with
NPM2 only.
• Various models of TCM cards cannot be
mixed.Use only TCM, TCM2, or TCM2+ in
your VMG-14+.
See also “VMG-14+ System Modules” on
page 26.
•AMP:2
• Others: up
to 12
Front,
slots 3 through 14.
Shelf Control
Manager (SCM)
Manage power and cooling, and system
inter-connectivity via interaction between
the SCM and Intelligent Management
Controllers (IPMC) over IPMB-0.
Enable system management through
Ethernet.
See also “Shelf Control Managers” on
page 19.
2Front, vertically
stacked slots at left
of Slot 1.
SCM2 (top)
SCM1 (bottom)
DC Power Entry
Modules (PEMs)
See also “DC System Power” on page 32.4Rear: in power bay
of DC systems.
DC PEM Terminal
Block Cover(s)
4For attachment to
DC PEM(s)
AC Power Entry
Modules
See also “AC System Power” on page 30.4Rear: in power bay
of AC systems.
AC Power Supplies 4Front:, in power bay
of AC systems.

SelenioTM VMG-14+ Hardware Setup Guide 19
VMG-14+ Chassis and Components Gen2 Release 1.4.0
ShelfControlManagers
The VMG-14+ SCMs fit into the dedicated SCM slots located at the left-front-edge of the chassis. Two
SCMs are required for redundancy, and an SCM in either slot can serve as the primary. When the active
is removed, the remaining SCM changes state—from standby to active.
Note: Although each Shelf Manager module contains a mini DB25 Telco Alarm interface at the RS-232
port, telco alarm LEds, and Telco alarm cutoff push button, the current release does not support
Telco alarm functionality.
The SCM faceplate provides the LEDs and components illustrated in Figure 8, and described in Table 4.
Figure 8. Shelf Control Manager Front Panel
Filler Panels
• Front Filler
• RTM Filler Panels
See also “Filler Panels” on page 34. all empty slots
Fan Tray See also “Fan Trays” on page 21. 2 Fan Tray slot, below
cable management
tray.
Fan Filter Tray See also “Fan Filter Tray” on page 22. 1 Front of chassis,
above fan trays, and
below cable
management tray.
Table 3. VMG-14+ Chassis Modules and Components (Continued)
Name Description System
Capacity Slot Assignments
Table 4. Shelf Control Manager—Front Panel
LED Name Color/Condition Description
Cutoff Button n/a Not supported for the current release.
Reset Button (RST) n/a Reset (power cycle) the SCM. Use a small pointed
object to access and depress this button.
Fault LEDs Green Temperature normal: not exceeding thresholds. This
LED illuminates upon system power-up.
Red Temperature exceeds thresholds.
Ethernet Link
Activity Status
RJ-45 Port ResetRS-232 Port
(not used)
Hot Swap
LED
SCM Status LED
Alarm
Cutoff
Fault
LEDs
Extraction
Lever
Fixing
Screw
Fixing
Screw

SelenioTM VMG-14+ Hardware Setup Guide 20
VMG-14+ Chassis and Components Gen2 Release 1.4.0
Steps for servicing of the Shelf Control Managerare provided in Chapter 5, Shelf Control Manager
Servicing on Page 64.
SerialConsoleConfiguration—SCM
•115200 baud
•No parity
•8 data bits
•1 stop bit
•no flow control
SCM Status (ShMM) Solid Green Active. This LED illuminates upon system powerup.
Blinking Green Standby.
Red Failure.
Hot Swap (FRU) Off SCM is not ready to be removed or disconnected from
the chassis.
Blue SCM is ready to be removed or disconnected from the
chassis.
RJ-45 port Solid/blinking green
Note that the RJ45 LEDs
illuminate even if the cable is
not inserted, to report status
of Ethernet link activity over
the VMG-14+ backplane.
10/100 link status and activity.
10: The RJ-45 port is operating in 10 Mbps mode
(data is being received or transmitted at 10 Mbps).
100: The RJ-45 port is operating in 100 Mbps mode
(data is being received or transmitted at 100 Mbps).
Pinouts for this port are provided in “10/100 Ethernet
Connector,” on this page.
RS-232 port n/a Not supported in the current release for Telco alarm
functions. However, you can directly connect to it for
troubleshooting purposes. See also “Serial Console
Configuration—SCM” on page 20, and “10/100
Ethernet Connector” on page 21.
Table 4. Shelf Control Manager—Front Panel (Continued)
LED Name Color/Condition Description
Table of contents