FUNCTION
The PulseWorx Gateway is a Powerline
I
nterface
Module
much like our
PIM-R RS-232
version that contains an
IP
Web
server and a
T
i
med
Event
Controller.
T
h
is
all-in-one device
makes it easy to enable UPStart Configuration Software or
other IP based device to communicate with a
UPB
network
and devices via a hardwired or
wireless
LAN
network or even
over the
internet.
The PGW
is simple to install – just plug it in to any standard
120VAC
wall outlet and connect a
CAT-5
cable between
it
and a network.
The
long distance capability of a network and
internet makes it possible to locate the PGW virtually
anywhere on site. The PGW is securely accessed with
an
assigned port while username and password protection is
enforced upon connection.
T
h
is
enables remote
c
onnection
of UPStart to a
PulseWorx/UPB
system to access and up
date
an installation or the use of smart phones or tablets with
t
h
e appropriate applications. No additional wiring is required
and no radio frequency
signals
are used for communication.
IMPORTANT SAFETY
INSTRUCTIONS
When using electrical prod
uct
s
,
basic safety precauti
ons
should
always
be
followed,
including the following:
1.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS.
2.
Keep
away from water. If the product comes in
contact
with water or other
liquid,
turn off the circuit breaker
and unplug the product immediately.
3.
Never
use products that have been dropped or damaged.
4.
Do
not use this product outdoors.
5.
Do
not use this product for other than its
int
ended
purpose.
6.
Do
not cover this product with any material when in
the
“
Discover PulseWorx Gateway
”
butto
n.
7.
This
product uses a grounded outlet to reduce the
risk
of
electric shock.
These
plugs and sockets fit only one way.
If they do not fit, consult an electrician.
8.
SAVE THESE
IN
STRUCTIONS.
INSTALLATION
The PGW
is designed for indoor use with a router or hub connected
to
a network.
To
install the
PGW
module follow these steps:
1. Connect an Ethernet cable
(sold
separately) between the
PG
W’s
RJ45
connector and any open port of the router, hub or
network.
2. Plug the
PGW
into any grounded wall outlet.
The
Status
LED
on
the front of the unit should start
blinking
and then stay solid
blue.
3.
The
two
Network
LED’s
on the
RJ45
connector should be solid
orange and
blinking
green once on line.
Status
LED
Indications
The PGW
contains a bi-color
(blue/red)
Status
LED
that
will
also give
a
visual
indication of what
UPB
information is currently on
th
e
powerline.
Blue:
No
UPB
Signal
Magenta:
Received
a
UPB
Message
Red: Transmitted
a
UPB
Message
CONFIGURATION
The PGW is the perfect interface device for use with
PCS’
UPStart
Configuration Software.
To
use the
PGW
with UPStart
Press
the
“Configure”
button in
the
“Powerline
Interface” panel in the
“Network”
tab to bring up the
UPB
Interface Setup dialog.
Select the
“PulseWorx Gateway”
as the Interface
Type
and then press use.
Quick
Start
Guide
PulseWorx
Gateway
PGW
19215 Parthenia St. Suite
D
Northridge,
CA
91324
P:
818.701.9831
pcssale
s
@
p
csl
i
ghting.com
www.
pcs
l
ighting.com
https://pcswebstore.com
©2015 Powerline Control Systems,
Inc.
All
Rights Reserved
v1.1
UPStart will automatically locate the
PGW
on your network
and fill in the
IP
address.
NOTE: The PGW
is
shipped
in
DHCP
mode.
If the IP address does not show up in the
“By
IP Address
window”,
re-click the
“Discover PulseWorx
Gateway”. If
the
PGW
can not be located, their might be issues with
eith
er
the network or
possibly
the PGW.
OPERATION
When the
PGW
is located and an
IP
address has been
assigned,
you can now connect
UPStart. Click
on the Connect
butto
n.
Setting the
IP
Add
r
ess
Now
that you are connected to the
PGW
select
“Network
Settings.”
At this point you have a choice to leave the device in
DHCP mode,
use
the assigned
IP
address or set your own address.
Enter the IP address, subnet mask, and default gateway to configure
the
PGW
on your network.
Y
ou may also change the access port o
n
your router. Note: We
recommend
that it is outside of
DHCP
pool
so its
network address
stays the same. The default router port is
2101.
If
you assign a static address you must disconnect from
UPStart
and then
power
cycle the
Gateway
for the
IP address
to
take
effect.
To
close the Gateway Network settings
click OK.
To
close the
UPB
Interface Setup dialog window
click
the Close
butto
n.
LIMITED
W
A
RRANTY
Seller warrants this product, if used in accordance with all applicable
instructions, to be free from original defects in materials and
workmanship for a period of five years from the date of pu
rchas
e
.
Refer to the warranty information on the
PCS
website
(www.pcslighting.com)
for exact details.
When the communication path is operational, UPStart reads
the firmware version and other items and
displays
what was
read.
“Selected powerline interface is operational” will be visible
upon
co
nnecti
on.

Popular Gateway manuals by other brands

ABB Ability user manual

ABB

ABB Ability user manual

ALTA Monnit MNG2-4-CME-CCE-ND user guide

ALTA

ALTA Monnit MNG2-4-CME-CCE-ND user guide

Dinstar DAG1000-4S Quick installation guide

Dinstar

Dinstar DAG1000-4S Quick installation guide

Nokia AD-42W user guide

Nokia

Nokia AD-42W user guide

Teltonika TRB141 quick start guide

Teltonika

Teltonika TRB141 quick start guide

cypress solutions CTM-ONE Installation

cypress solutions

cypress solutions CTM-ONE Installation

ELTEX TAU-4M.IP Operation manual

ELTEX

ELTEX TAU-4M.IP Operation manual

flamco Smart Node 2 Instruction & installation manual

flamco

flamco Smart Node 2 Instruction & installation manual

XLOCK 100 instruction manual

XLOCK

XLOCK 100 instruction manual

Media5 Mediatrix 4108 Hardware installation guide

Media5

Media5 Mediatrix 4108 Hardware installation guide

Cisco EPC3925 datasheet

Cisco

Cisco EPC3925 datasheet

Neptune Technology R900 Installation supplement

Neptune Technology

Neptune Technology R900 Installation supplement

Teltonika Voice Fax Gateway user manual

Teltonika

Teltonika Voice Fax Gateway user manual

AsiaRF AP7628-UWH manual

AsiaRF

AsiaRF AP7628-UWH manual

Banner SureCross DX80 manual

Banner

Banner SureCross DX80 manual

ZyXEL Communications AMG1001-T10A Specifications

ZyXEL Communications

ZyXEL Communications AMG1001-T10A Specifications

Energy Genius GGAT-1 user manual

Energy Genius

Energy Genius GGAT-1 user manual

Tescom Ts2 user guide

Tescom

Tescom Ts2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.