4
SECTION 2: CONTROLS
REMOTE OPERATION
On first use insert the batteries into the remote control handset - see battery replacement
section. With mains supply connected and the fire switched on the fire can be operated.
CARE
DO NOT drop - DO NOT immerse in liquids - DO NOT leave flat batteries in the unit -
Clean only with a dry cloth.
As this product operates using infra-red, ensure there is a
clear line of sight between the handset and the appliance for
it to operate effectively.
By pressing the ON/OFF button the operational features of
the fire are enabled; if you then press the LAMP button the
Visual effect will operate; if you then press the HEAT 1 button
the 1kW heat setting will operate together with the Visual
effect; if you then press the HEAT 2 button the 2kW heat set-
ting will operate together with the Visual effect. From here if
you press a different button it will go back to that status - if
you press the O/OFF button it will turn the fire off. Please
note that it is possible to miss out steps once the operational
features are enabled e.g. if you press the ON/OFF button
then the HEAT2 button the fire will go straight to 2kW together with the Visual effect.
NOTE: Each function is accompanied by an audible beep.
MANUAL OVER-RIDE OPERATION
If the Remote handset is mislaid or the batteries run out the fire can be operated manually
by use of the membrane pad situated next to the thermostat.
With the mains supply connected and the fire switched on the fire can be operated.
By pressing the ON/OFF FUNCTION button the features of the
fire can be used. This is a single touch button and when pressed
sequences through the available functions.
NOTE: Each function is accompanied by an audible beep.
LED DISPLAY EXPLANATION
Red LED on LHS of pad illuminated: Fire in standby mode. (not
illuminated when other functions in use or fire is off)
Green LED on RHS of pad flashes 5 times then goes out: Visual effect on.
Amber LED on RHS of pad flashes 5 times then goes out: Visual effect + 1kW on.
Red LED on RHS of pad flashes 5 times then goes out: Visual effect + 2kW on.
THERMOSTAT
The thermostat enables the room temperature to be controlled around a pre-set level and
can be used when the 1Kw or 2Kw switches are on (this is best done prior to fitting the
Frame). To set the thermostat, first set the control at position 9 then turn on the heating
elements and heat the room to the desired temperature. When this temperature has been
reached reduce the setting by turning the control anti-clockwise towards a lower figure
until you hear the thermostat click off and the heat from the fan stops. When the room
temperature drops the thermostat will turn the fire back on again until the selected heat
setting is reached.
The thermostat control is designed to operate at room temperatures of 0 – 40oC.
At very low temperatures (approx. 6° C) the thermostat will NOT turn the fire off until the
temperature rises above approx. 8°C.