Function setting
Operation flowchart
The difference between dynamic detection
and static detection
The sensitivity of dynamic detection is higher than that of static
detection. Dynamic detection is suitable for fast moving detection
of metal objects(such as counting) , while static detection is more
suitable for metal proximity detection(such as wire detection).
Output white line grounding and hanging correspond to NPN NO and
NC output respectively.
1、Press the "Mode”and“Enter" buttons at the same time, for more
than 3 seconds. The display shows“Fn”, it means the sensor has
2、
F1 is usd to set ON_Delay time, which ranges from 0 to 99, and
the corresponding time length is about 0 to 25 ms.
F2 is usd to set OFF_Delay time, which ranges from 0 to 99, and
the corresponding time length is about 0 to 25 ms.
F3 is usd to set One_Shot time, which ranges from 1 to 99, and the
corresponding time length is about 1 to 100 ms.
F4 is usd to set One_Shot time, which ranges from 1 to 99, and the
corresponding time length is about 1 to 100 ms.
F5 is usd to set the output mode. If it is 1, select the output mode
of One_Shot for the sensor; if it is 0 by default, select the normal
output mode.
F6 is used to set detection mode, dynamic detection mode is
selected when it is 0, and static detection mode is selected when
it is 1.
in ys display state, all parameters are automatically set to
the factory mode.
Connection
Sensitivity adjustment
Output mode conversion method
1、After pressing the “Mode” button once, the unit’s digit of the
sensitivity will be increased by 1. If you hold it for more than 2
seconds, the display will automatically increase the number by 1,
and the biggest number is 99.
2、After pressing the “Enter” button once, the unit’s digit of the
sensitivity will be decreased by 1. If you hold it for more than 2
seconds, the display will automatically decrease the number by 1,
and the smallest number is 0.
10-30VDC
+
-
Brown
Black
Blue
1
2
White
Definition Range Default parameter
ON_Delay 0~99 0
OFF_Delay 0~99 0
One_Shot 1~99 5
OFF_Shot 1~99 1
Output mode 0
0
- /1 - 0 -
Detection mode - -1 - 0
Factory_setting no/ys no
/
※1:Load connection for NPN output
※2:Load connection for PNP output
Fn
F1
Mode Enter
0~99 0~99
F2 0~99 0~99
F3 1~99 1~99
F4 1~99 1~99
F6 - 0 - 1
F7 no ys
F5 0 - 1 -
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Enter
Enter
Enter
Enter
Enter Enter
Enter Enter
Enter
Enter
Enter Enter
Enter
Enter
Power indicator Output indicator
Caution for using
Main product
Photoelectric sensor
Light curtain
Proximity sensor
Pressure sensor
Counting sensor
Distance sensor
Liquid level sensor
Label sensor
Hall sensor
Pressure meter
Counting machine
Dust sensor
Intellisense Microelectronics
Tel:0592-8268993
Tax:0592-8268997
Web:www.chinasensors.cn
E-mail:sales@chinasensors.com.cn
Add:1F NO. 34 Guanri Rd, Xiamen software Park,Xiamen P.R. China
1、Please make sure the wiring is correct before power-on.
2、Use a visor or a hood so that excessive light(e.g. sunlight, spotlight)does not directly
enter into the inclination angle of the sensor.
3、When more than 2 sets of Through-beam type sensor are used closely,it might cause inter-
4、Sensor can mulfunction due to light entering from adjacent sensor, so sensors must be
installed with enough seperated distance.
5、If the sensor is installed directly on a flat surface, the reflection off the surface may cause
malfunction. Make sure there is enough space between the sensor and the surface.
6、If the sensor is wired with a high voltage line or power line, it may cause product damage
or malfunction. Use separate wiring or a dedicated conduit.
7、Please use short cables for wiring the sensors. Power surge from extended wiring may cause
product malfunction;
8、When the lens is stained by foreign substances, clean the lens lightly with dry cloth. Do not
use chemical or organic solvents.