IMS RX5 User manual

IMS
Inductive Ring Sensor
Dimensions
Non
Alarm output
A
CX 30 68 Tn Vn 3 N F
Reset time
O
Fixing
On-delay function
A
Response time
Item
*(2)
Number Unit:mm
Vn Channel spacing
nNumber,4、6、8...
Number Unit:mm
Number Unit:mm
V:Channel spacing ,n:number(mm)
Tn:channel number,no need to fill in single channel
Length of sensing area,no need to fill in the ring series
Width of sensing area
Accuracy/Sensitivity
*(1)
Output
CX
RX
EX
Frame seires
Ring series
Slot series
PG Miniature
Fixing
Off-delay functionF
NPN
PNPP
N
O
Alarm
Model
Sensing hole
0.7mm 1.2mm 3mm 4mm
Max. 100mA
NPN、PNP
Minimum Resolution
Output
Circuit protection
Response time
Life expectancy
Power voltage
Application range
Cable
Current consumption
Load current
Material
Degree of protection
Weight
Accessory
φ4mm,4-wire,Length:2m
25mA Max.(not including the load)
DC10~30V(including voltage ripple of 10%(p-p)max.)
PC
Instruction,M4*12(2 pcs)
IEC:IP64
Approx. 85g
RX5 RX10 RX18 RX30
D=5mm D=10mm D=18mm D=30mm
Case
Button
Bushing
silicone
silicone
Metal particles
Power on delay,power supply reverse polarity protection,output
short-circuit protection,output reverse polarity protection
1ms
Sensitivity adjust Key
100,000 times min.(frequency of opening and closing:1,800 times per hour)
Ambient illumination
Ambient temperature
Ambient humidity
Incandescent lamp:Max. 5,000lx /Sunlight:Max. 50,000lx
Operation:-20 ~ 65 ℃/Storage:-25 ~ 80 ℃(with no icing and
condensation)
Operation:45 ~ 85%RH/Storage:35%~95%RH(with no condensation)
The influence of metal proximity to sensing area
If a moving metal part is near the sensing area, the sensor output may
be disturbed. To avoid this, keep a distance from the metal object when
installing the sensor to ensure that the sensor function correctly.
Every object passing through the sensor should be spaced at least one
sensor width distance. If more than a sensor is installed in the adjacent
area, the minimum distance between the sensors must be observed as
shown in the following table.
Model RX5 RX10 RX18 RX30
A(Fig.1)mm
B(Fig.2)mm
60 80 100 120
10 30 50 70
※ For each model, except for the hole dimension (φ18), the other dimensions are the
same as above.
INSTRUCTION MANUAL
! WARNING
! CAUTION
Thank for you selecting IMS product.This sheet primarily describes precautions
required in installing and operating the product.Before operating the product,read
the sheet thoroughly to acquire sufficient knowledge of the product.For your
convenience,keep the sheet at your disposal.
Failure to follow these instructions may result in serious injury or death:
Fail-safe device must be installed when using the unit with machinery that may
cause serious injury or substantial economic loss. (e.g. nuclear power control,
medical equipment, ships, vehicles, railways, aircraft, combustion apparatus,
safety equipment, crime/disaster prevention devices, etc.)
Failure to follow these instructions may result in product damage:
Do not use this unit over rated voltage;
Do not use this unit where there is flammable or explosive gas;
Do not use this unit where there is vibration or impact;
In cleaning the unit, do not use water or an oil-based detergent.
Features
Ordering information
Suitable for the detection of small metal object
Digital display, sensitivity can be adjusted according to the size of object
There are various ring dimension to meet different requirements
Dual LED makes you easy to know the current operating situation
Only 12mm thickness, to meet the high-speed blanking requirements
Specifications
*(1) :Accuracy refers to the smallest particle size to achieve no blind area detection;
*(2) :Non-standard structure can be designed.

Function setting
Operation flowchart
The difference between dynamic detection
and static detection
The sensitivity of dynamic detection is higher than that of static
detection. Dynamic detection is suitable for fast moving detection
of metal objects(such as counting) , while static detection is more
suitable for metal proximity detection(such as wire detection).
Output white line grounding and hanging correspond to NPN NO and
NC output respectively.
1、Press the "Mode”and“Enter" buttons at the same time, for more
than 3 seconds. The display shows“Fn”, it means the sensor has
2、
F1 is usd to set ON_Delay time, which ranges from 0 to 99, and
the corresponding time length is about 0 to 25 ms.
F2 is usd to set OFF_Delay time, which ranges from 0 to 99, and
the corresponding time length is about 0 to 25 ms.
F3 is usd to set One_Shot time, which ranges from 1 to 99, and the
corresponding time length is about 1 to 100 ms.
F4 is usd to set One_Shot time, which ranges from 1 to 99, and the
corresponding time length is about 1 to 100 ms.
F5 is usd to set the output mode. If it is 1, select the output mode
of One_Shot for the sensor; if it is 0 by default, select the normal
output mode.
F6 is used to set detection mode, dynamic detection mode is
selected when it is 0, and static detection mode is selected when
it is 1.
in ys display state, all parameters are automatically set to
the factory mode.
Connection
Sensitivity adjustment
Output mode conversion method
1、After pressing the “Mode” button once, the unit’s digit of the
sensitivity will be increased by 1. If you hold it for more than 2
seconds, the display will automatically increase the number by 1,
and the biggest number is 99.
2、After pressing the “Enter” button once, the unit’s digit of the
sensitivity will be decreased by 1. If you hold it for more than 2
seconds, the display will automatically decrease the number by 1,
and the smallest number is 0.
10-30VDC
+
-
Brown
Black
Blue
1
2
White
Definition Range Default parameter
ON_Delay 0~99 0
OFF_Delay 0~99 0
One_Shot 1~99 5
OFF_Shot 1~99 1
Output mode 0
0
- /1 - 0 -
Detection mode - -1 - 0
Factory_setting no/ys no
/
※1:Load connection for NPN output
※2:Load connection for PNP output
Fn
F1
Mode Enter
0~99 0~99
F2 0~99 0~99
F3 1~99 1~99
F4 1~99 1~99
F6 - 0 - 1
F7 no ys
F5 0 - 1 -
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Enter
Enter
Enter
Enter
Enter Enter
Enter Enter
Enter
Enter
Enter Enter
Enter
Enter
Power indicator Output indicator
Caution for using
Main product
Photoelectric sensor
Light curtain
Proximity sensor
Pressure sensor
Counting sensor
Distance sensor
Liquid level sensor
Label sensor
Hall sensor
Pressure meter
Counting machine
Dust sensor
Intellisense Microelectronics
Tel:0592-8268993
Tax:0592-8268997
Web:www.chinasensors.cn
E-mail:sales@chinasensors.com.cn
Add:1F NO. 34 Guanri Rd, Xiamen software Park,Xiamen P.R. China
1、Please make sure the wiring is correct before power-on.
2、Use a visor or a hood so that excessive light(e.g. sunlight, spotlight)does not directly
enter into the inclination angle of the sensor.
3、When more than 2 sets of Through-beam type sensor are used closely,it might cause inter-
4、Sensor can mulfunction due to light entering from adjacent sensor, so sensors must be
installed with enough seperated distance.
5、If the sensor is installed directly on a flat surface, the reflection off the surface may cause
malfunction. Make sure there is enough space between the sensor and the surface.
6、If the sensor is wired with a high voltage line or power line, it may cause product damage
or malfunction. Use separate wiring or a dedicated conduit.
7、Please use short cables for wiring the sensors. Power surge from extended wiring may cause
product malfunction;
8、When the lens is stained by foreign substances, clean the lens lightly with dry cloth. Do not
use chemical or organic solvents.
This manual suits for next models
3
Other IMS Accessories manuals
Popular Accessories manuals by other brands

elero
elero Aquero manual

Barbarian Basketball Systems
Barbarian Basketball Systems Titanium Series Assembly instructions and owner's manual

SkyWriter
SkyWriter SL-300 instruction manual

Oase
Oase InScenio 230 operating instructions

GolfAchiever
GolfAchiever GA SIM Setup guide

Byron
Byron BY201F Installation and operation instruction