RFID TRANSPONDER TECHNOLOGY
DOC. 212-R2-ENG
EK20-IDSCAN USER MANUAL
The “RFIDSCOPE”
ID-SCAN is a powerful RFID detector covering all the most used transponders on the market.
The function LF/HF/UHF SCANNER permits to identify a tag in few seconds.
The function PAGE READ permits to read the memory contents (UID/EPC,TID,USER PAGE)
The tags actually detected by IDSCAN are listed below:
LF SCANNER 125 KHz
Type Page Read
UNIQUE-EM4102 UID only
Q5 UID/PAGE Read from front side (LF-HF)
TK5577 UID/PAGE
TITAN-EM4550 UID/PAGE
HITAG 1 UID/PAGE
HITAG 2 UID/PAGE
HITAG S UID/PAGE
HITAG 256 UID/PAGE
HF SCANNER 13.56 MHz
Type Page Read
14443A
MIFARE 1K UID/PAGE
MIFARE 4K UID/PAGE
MIFARE ULTRALIGHT UID/PAGE
MIFARE PLUS UID
MIFARE DESFIRE_D40 UID
MIFARE DESFIRE_EV1 UID
MIFARE DESFIRE_EV2 UID
14443A GENERIC UID/PAGE
15693
ICODE NXP 1K UID/PAGE
ICODE NXP 2K UID/PAGE
LRI-2K STM
15693 GENERIC UID/PAGE
14443B
SRIX STM 512 UID/PAGE
SRIX STM 4K UID/PAGE
ST19-WR08 STM UID
CALYPSO UID
14443B GENERIC UID/PAGE Read from bottom side(UHF)
UHF SCANNER 868MHZ (EU)
Type Page Read
MONZA2 EPC/TID/PAGE
MONZA3 EPC/TID/PAGE
MONZA4D EPC/TID/PAGE
MONZA4U EPC/TID/PAGE
MONZA4QT EPC/TID/PAGE
MONZA4E EPC/TID/PAGE
MONZA5 EPC/TID/PAGE
HIGGS2 EPC/TID/PAGE
HIGGS3 EPC/TID/PAGE
UCODE G2XM EPC/TID/PAGE
UCODE G2XL EPC/TID/PAGE
UCODE G2iL EPC/TID/PAGE
UCODE G2iL+ EPC/TID/PAGE
UHF GENERIC EPC/TID/PAGE
Permits to read EPC lengths from 2 to 16 bytes.

2
OPERATION MODE
IDSCAN use two area to operate:
WORKING AREA is the scan operation area.
SETTINGS AREA is an area where to set some useful parameters.
TURN ON/OFF
TURN-ON Press for a short time the key
TURN-OFF Press the key for about 2 sec.
WORKING AREA
After turn on the LCD display the current version.
If IDSCAN remains inactive for more than 3 minutes automatically will be turn off to preserve the battery.
LOW BATTERY
If a low battery is detected appears:
The LCD lamp and BUZZER flash three times and IDSCAN turn-off.
If no alarm detected appears :
BATT: show the battery level %.
RFID SCANNER
To start the tag detection press .
IDSCAN attempt to recognize an unknown transponder.
Before it run a scan on LF frequency
and next a scan on HF
and next a scan on UHF
When a TAG is detected the LCD lamp and BUZZER flashes 3 times.
On the LCD appear the Tag Type and the UID detected.
The UID length and meaning is different for any Type of Tag.
Refer to the “Technical Specification” of that TAG.
If no detection:
PAGE READ
Place the TAG in the RF field.
To read the UID press .
To read the PAGES on the tag use to increment or decrement
the PAGE number and press .
Will appear the read value in HEX format.
If a Data Error was detected appear Read Error.
To repeat press
IDSCAN 5.0
Low Battery
Scanner Ready
BATT: - - - -
Running LF
Running HF
Running UHF
HITAG-1 UID
TAG UNKNOWN
HITAGS UID
34C456F8
HITAGS 004
12345678
HITAGS 004
Read Error

3
SOME EXAMPLES
UNIQUE-Q5-TK5557
The UID display the content of the USER AREA in HEX format (5bytes).
Q5 and T5577 have a PAGE containing an UNIQUE SERIAL NUMBER.
Use to change to PAGE 000 and press .
Q5 PAGE Serial Code (5 bytes HEX).
T5577 PAGE Serial Code (8 bytes HEX).
HITAG S
Read Serial Code (4 bytes HEX)
Read Page 004 (4 bytes HEX)
ISO 14443A
MIFARE CLASSIC 1K Serial Code (4 byte Hex)
Select a Page (Block 001)
Then press to display 16 bytes HEX of the selected page.
ISO 15693
ICODE NXP 1K Serial Code (5 bytes HEX).
Read PAGE 002 (4 bytes HEX).
ISO 14443B
SRIX-ST-512 Serial Code (8 bytes HEX).
Read PAGE 010 (4 bytes HEX).
UHF
MONZA5 EPC Code (12 or 16 bytes HEX or ASCII).
Press to display the EPC code
Use to change to TID and press .
Use to scroll the PAGES of USER AREA and press .
Any pages shows 16 bytes in HEX
Es. mode HEX
Es. mode ASCII
UNIQUE UID
15F53244D5
Q5 000
A534C21233
T5577 000
E015015576B4F899
HITAGS UID
467BF970
HITAGS 004
53535353
MIFARE-1K UID
5C63161D
MIFARE-1K 001
1234567890ABCDEF
FFFFF3245778BDE25
ICODE NXP 1K UID
0009CA1B95
ICODE NXP 1K 002
696F2050
SRIX-ST-512 UID
F082CB67C71802D0
SRIX-ST-512 010
33343536
MONZA5 EPC
3000000000000000
00000000
MONZA5 TID
E2801100200054C6
155F016F
MONZA5 002
3031303230333034
3035303630373038
Paul Smith
CAMRAS SA

4
SETTINGS AREA
To pass from WORK AREA to SETTINGS AREA and vice versa, hold down the ESC key for 3 seconds.
When enter the SETTING AREA appear the first selection of the MENU list.
1)
Set the SCAN MODE:
LH scan only LF and HF tags.
LU scan only LF and UHF tags.
HU scan only HF and UHF tags.
LHU scan all tags.
Lscan only LF tags.
H scan only HF tags.
U scan only UHF tags.
Pressing , the cursor moves on the selection and stores the value.
Scroll down to the next item.
2)
Set the reading mode of an UNIQUE code.
NORM is the INOUT format. Example: F040F2B370
INV is the SOKYMAT format 0F024FCD0E
Pressing , the cursor moves on the selection and stores the value.
Scroll down to the next item.
3)
Set the reading mode for EPC and USER MEMORY of an UHF tag.
ASC the reading is made in ASCII format.
HEX the reading is in HEX format.
Pressing , the cursor moves on the selection and stores the value.
Scroll down to the last item.
4)
Set all the Mifare Cripto KeyA for all Sectors at the default value: FFFFFFFFFFFF
into the reader chip.
Pressing , the cursor moves on the selection and stores the value.
Scroll down to the last item.
5)
Set the power on the UHF antenna between 15dbm to 16dbm (default=1).
Pressing , the cursor moves on the selection and stores the value.
AVAILABLE MODELS
EK20-IDSCAN-LH Model with LF and HF antennas
EK20-IDSCAN-LHU Model with LF and HF and UHF antennas.
The USB interface is always present in all the models.
SC:LH LU HU LHU
L H U
Unique:NORM INV
UHF_E_U:ASC HEX
MIF:ALL KEY DEFAULT
UHF POWER: 1 2 3 4

5
FIRMWARE AND TEXT UPGRADE
Open the folder: “IDSCAN_CD”
INSTALL THE DRIVER USB
1) Open the folder “MCP2200WindowsDriver”.
2) In “DriverInstallationTool” select “X64” forr 64bit or “X86” for 32 bit.
Launch “MCP2200DriverIstallationTool”. Press "Install" and wait for the end of the driver installation.
INSTALL COM PORT ON PC
1) Turn off the READER. Insert the USB connector and turn on the READER.
2) Begin he installation of a new device. Wait for the complete installation of the assigned COM PORT.
Turn on IDSCAN.
Will appear on the LCD:
Now double click on the icon to launch the program “EK20 UPLOADER”.
- Set the COM PORT and the bit rate at 19200.
- Press UPLOAD PROGRAM.
- Select the file IDSCAN_5.x.BIN
- Set the Reader address to which to send the program.
- Press START and wait for the text (Upload OK).
- Turn off the READER.
To upgrade the TEXT in different languages repeat the before operations selecting “Upload Language”
and load the file “IDSCAN_5.x.txt”.
TECHNICAL SPECIFICATION
USB Connected
Operate from PC
TRIPLE FREQUENCY
LF 125Khz HF 13.56Mhz UHF 868Mhz
READ DISTANCE
LF max 1,5cm HF max 2cm UHF max 10cm
DISPLAY LCD
2 row x 16 chari White-Blue
ACOUSTIC WARNING
Buzzer
BATTERY
LIPO 400mah rechargeable via USB (5VDC). Complete charge: 4hour
DATA TRANSMISSION 19200-8-N-1
USB2.0
OPERATING TEMPERATURE
-20’C to +65’C
DIMENSIONS
WEIGHT
125mm x 70mm x 23mm
170 grammi
INOUT RFID s.r.l Via Milano,14/H 20064-Gorgonzola (ITALY)
Phone:+39 02.95138.139 Fax:+39 02.95.158.694
Table of contents
Popular Security Sensor manuals by other brands

Guardian Fall Protection
Guardian Fall Protection 42001 instruction manual

Powerfix Profi
Powerfix Profi 273599 Operation and safety notes

i4Technology
i4Technology BugHunter Professional BH-03 Expert Operation manual

Mustang Survival
Mustang Survival RESCUE STICK MRD100 owner's manual

koban
koban KDP1 360FP manual

Blaupunkt
Blaupunkt DC-S2 quick guide