Inovonics FA130 User manual

FA130
Frequency Agile£900MHz
Wireless Keypad
Installation Instructions
02583B
800-782-2709
For technical support
or a
pp
lication assistance
Inovonics Wireless Corporation
315 CTC Blvd
Louisville CO 80027
www.inovonicswireless.com
Attention: The FA130 keypad requires Vision Plus
panel firmware
C2020 V1.4x or greater and FA400 receiver firmware V1.5x
or greater.
1
4
7
2
5
8
0
3
6
9
FIRE
POLICE
SPECIAL
EMERGENCY
STAY
AWAY
CUSTOM
OFF
REVIEW
CHIME
ENTER
Figure 1: FA130 Keypad
Recommended programming:
Type: KEYPAD
Monitored: No (Not Applicable)
Audible: No (Not Applicable)
Relay out: No (Not Applicable)
Recommended Check-in: 30 seconds*
Typical battery life: 3-4 years
Battery type: BAT604 Duracell DL123A 3V
Low battery monitoring: automatic
* Programmed check-in values are executed at 3-times the interval shown to
extend battery life. For example, " 30 seconds" results in a 90-second check-
in interval.
Important Notes
nThis product is designed to be installed and maintained by
professional security technicians.
nUnless specifically noted, Inovonics products are intended for
indoor use. This receiver is intended for use with indoor
security systems. Use in outdoor applications may impair
performance.
nTt t ll

FA130 Keypad
The FA130 keypad is a 900MHz wireless transmitter used to arm and disarm
the Vision Plus™ or Wireless Guardian™ system. The FA130 is a one-way
device, which can be programmed as a supervised point. Functionally, the
FA130 emulates the KP130 hardwire executive keypad, without the LCD
display.
PROGRAMMING THE KEYPAD:
1. If desired, identify the point number of the unit with numbered labels
provided with the Vision Plus™ or Wireless Guardian™ panel.
2. Turn the phillips-head screw on the bottom of the housing slightly.
Separate the housing halves.
3. Complete program data entry as shown below Figure 1. When prompted
to "Plug in Xmitter", connect the programming cable between
programming headers on the hardwire executive keypad and the FA130
wireless keypad. Refer to Figure 2 to locate the programming header.
4. Press the reset button on the FA130 keypad. When programming has
been confirmed by the hardwire executive keypad, disconnect the
programming cable.
5. Test the FA130. Pressing any arming key will cause the keypad to
transmit and the transmit LED under the ENTER key to flash during
transmissions. The panel will decode the message to determine if it is
valid.
6. Mount the keypad using hardware provided.
3.0V +
RESET BUTTON
PROGRAMMING
HEADER
TRANSMIT LED
(SURFACE MOUNT CHIP)
Figure 2: FA130 programming
MOUNTING THE FA130
1. Turn the phillips-head screw on the bottom of the housing one turn.
Separate the housing halves.
2. Use supplied hardware to attach the FA130 securely to a wall.
3. Use the mounting holes in the backplate as needed to locate screws or
wall anchors.
MOUNTING HOLES
(4 PLACES)
Figure 3: back housing mounting holes

Using the FA130
ENTERING ACCESS CODES: The FA130 "reads" access code keypresses on a first-in-first-out
basis. When an arming key or OFF is pressed, the keypad transmits only the last four digits
entered. If the user makes an error entering an access code, it is only necessary to re-enter the
correct code before pressing an arming key or OFF. If an arming key is not pressed within
15 seconds, the keypad will clear any input data.
TO ARM THE SYSTEM: enter the access code, and press the STAY, AWAY or CUSTOM key.
The Transmit LED will light indicating that the keypad is sending data.
TO ARM THE SYSTEM (EZ ARMING ENABLED): Press ENTER followed by STAY, AWAY or
CUSTOM. Normal entry and exit delays will be in effect. FOR INSTANT MODE: Press the STAY
or the CUSTOM key again during the delay period. All delayed points will be armed as instant.
TO DISARM THE SYSTEM: Enter an access code-and press the OFF key.
TO HEAR ARMING STATUS from the nearest hardwire keypad or from an audio speaker
connected to the control panel: Press the REVIEW key on the FA130 keypad. See Figure 4 for
descriptions of various status tones.
OFF (DISARMED
)
ARMING AWAY MODE
ARMING HOME MODE ARMING CUSTO
M
Figure 4: Arming Status Tones
OTHER STATUS TONES: The Vision Plus or Wireless Guardian™ system will generate status
tones from the hardwire executive keypad and the audio output as shown in Figure 5.
ALARM ON SENSO
R
PROGRAMMED
AUDIBLE = "YES"
ENTRY or EXIT CHIME
FIRE ALARM OR
KEYPAD FIRE ALAR
M
SENSOR INACTIVE OR
LOW BATTERY
(7-SECOND INTERVAL)
SYSTEM NOT READY
(WHEN ARMING) DELAY SENSOR T
R
(2-SECOND INTER
V
ALARM HAS OCCURRED
(WHEN DISARMING)
DISARMING
Figure 5: Panel status tones
Using the Emergency Alert Keys
POLICE
SPECIAL
EMERGENCY
STAY
AWAY
CUSTOM
OFF
REVIEW
CHIME
ENTER
FIRE
Figure 6: FA130 function keypad
NOTE: TO USE EMERGENCY ALERT KEYS, EZ ARMING MUST BE ENABLED.
Keypad emergency alarms can be activated by pressing the ENTER key, followed by the
appropriate key. (See Figure 6.) The CHIME function, activated by pressing ENTER, then
CHIME, is available regardless of the EZ ARMING status. These keys activate the system
alarm and send a keypad emergency code to the monitoring station, if selected.
TO SEND A KEYPAD FIRE ALERT: ENTER FIRE
TO SEND A KEYPAD POLICE ALERT: POLICE
ENTER
TO SEND A KEYPAD SPECIAL ALERT: SPECIAL
ENTER
TO SEND A KEYPAD EMERGENCY ALERT: EMERGENCY
ENTER
TO TURN CHIME ON AND OFF: CHIME
ENTER
The chime function is always available. It silences or activates the chime feature on
disarmed intrusion points which have been programmed with chime enabled.

Warranty & Disclaimer
Inovonics Wireless Corporation ("Inovonics") warrants its products
("Product" or "Products") to conform to its own specifications and to be
free of defects in materials and workmanship under normal use for a
period of twenty-four (24) months from the date of manufacture. Within
the warranty period Inovonics will repair or replace, at its option, all or any
part of the warrantied product. Inovonics will not be responsible for
dismantling and/or reinstallation charges. To exercise the warranty, the
User ("User", "Installer" or "Consumer") must be given a Return Material
Authorization ("RMA") Number by Inovonics. Details of shipment will be
arranged at that time.
This warranty does not apply in cases of improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse,
accident or tampering, and repair by anyone other than Inovonics.
This warranty is exclusive and expressly in lieu of all other warranties,
obligations or liabilities, whether written, oral, express, or implied,
including any warranty of merchantability or fitness for a particular
purpose. Inovonics will not be liable to anyone for any consequential or
incidental damages for breach of this warranty or any other warranties.
This warranty will not be modified, varied or extended. Inovonics does not
authorize any person to act on its behalf to modify, vary or extend this
warranty. This warranty will apply to Inovonics products only. All other
products, accessories or attachments used in conjunction with Inovonics
equipment, including batteries, will be covered solely by their own
warranty, if any. Inovonics will not be liable for any direct, incidental or
consequential damage or loss whatsoever, caused by the malfunction of
Product due to products, accessories, or attachments of other
manufacturers, including batteries, used in conjunction with Inovonics
products.
This warranty does not warrant the replacement of batteries that are used
to power Inovonics Products.
The User recognizes that a properly installed and maintained security
system may only reduce the risk of events such as burglary, robbery,
personal injury and fire. It does not insure or guarantee that there will be
no death, personal damage and/or damage to property as a result.
Inovonics does not claim that the Product may not be compromised
and/or circumvented, or that the Product will prevent any death, personal
and/or bodily injury and/or damage to property resulting from burglary,
robbery, fire or otherwise, or that the Product will in all cases provide
adequate warning or protection.
Inovonics shall have no liability for any death, injury or damage, however
incurred, based on a claim that Inovonics Products failed to function.
However, if Inovonics is held liable, directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of
cause or origin, Inovonics' maximum liability will not in any case exceed
the purchase price of the product, which will be fixed as liquidated
damages and not as a penalty, and will be the complete and exclusive
remedy against Inovonics.
!
Warning: The User should follow all installation, operation and
maintenance instructions. The User is strongly advised to
conduct Product and systems tests at least once each
week. Changes in environmental conditions, electric or
electronic disruptions and tampering, may cause the
Product to not perform as expected.
!
Warning: Inovonics warrants its Product to the User. The User is
responsible for exercising all due prudence and taking
necessary precautions for the safety and protection of lives
and property wherever Inovonics Products are installed.
Inovonics strongly advises the User to program Products to be
supervised whenever used in applications affecting life safety.
Users are warned that unsupervised devices are subject to
undetected failure due to malfunction, battery failure,
tampering, or changes in environment.

Table of contents