Status indicators
The status indicators on the keypad provide a quick
visual reference for system status.
The indicator lights when the system is ready to turn on (arm).
The indicator lights when the system is on (armed).
The indicator lights when there is a trouble condition.
The indicator lights when dangerous gases are present including
carbon monoxide (NFPA 720).
The indicator lights when the system has power.
Audible tones
The keypad has a built-in speaker that produces
several distinct warning tones. The keypad backlight
illuminates when it emits an audible tone. You can use
a passcode to silence the tone.
The tones include:
• Fire signal. When an area is in fire alarm, the keypad
emits a pulsed, high-pitched bell tone.
• Gas signal. When a gas point activates, the keypad
emits a unique high pitched tone.
• User alarm. When a user alarm (such as panic and
medical alarms) occurs, the tone sounds for the
programmed amount of time.
• Burglary signal. When an area is in alarm, the keypad
emits a steady, high pitched bell tone.
• Entrance warning. The keypad emits an intermittent
beep tone during entry delay periods to remind the
user to disarm the area.
• Exit warning. The keypad emits an intermittent beep
tone during exit delay.
• Invalid button buzz. When an invalid button, or
sequence of buttons, is pressed, the keypad emits a
flat buzz tone.
• Keypad encoding tone. The keypad emits a muted
beep tone as each button is pressed to indicate that
the entry was accepted.
• Trouble buzzer. When a trouble event occurs, such as
a service alert, the keypad emits a two-tone warble
until you enter a programmed passcode with the
appropriate authority.
• Watch tone. A single clean tweedle tone alerts the
user anytime a watch point is faulted.
Certifications and approvals
Region Regulatory compliance/quality marks
Australia RCM ACMA
Europe CE EMC, RoHS [B915, B920, B930, B430,
B208, B308, B901]
USA UL
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 636 - Holdup Alarm Units and Sys-
tems
Region Regulatory compliance/quality marks
UL UL 985 - Household Fire Warning Sys-
tem Units (6th edition)
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
CSFM California State Fire Marshal
FCC Part 15 Class B
Canada ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
ULC Underwriters Laboratories of Canada
S1871-20121210
IC ICES-003 - Information Technology
Equipment (ITE)
Installation/configuration notes
Mounting considerations
Mount in indoor, dry locations.
Power supply
A compatible control panel supplies the power and
data requirements to the keypad through a four-wire
connection.
Enclosure and wiring
The sliding self-locking enclosure has an integrated
bubble level and custom gap-free, lift-gate style
terminal blocks to make installation easier.
Compatible control panels
B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512/B5512E firmware v2.02 and higher
B4512/B4512E firmware v2.02 and higher
B3512/B3512E firmware v2.02 and higher
D9412GV4/D7412GV4 firmware v2.02 and higher
Parts included
Quan
tity
Component
1Keypad
1 Hardware pack
2| B930 ATM Style-Alpha Numeric Keypad (SD12)