FEATHERWEIGHT
22 FEATHERWEIGHT BIRD SCALE rev.01
Scale 2
Calib weight: 10000
Push + for next step
Scale is: Empty
5.6.4 Scale Calibration
The scales must be calibrated regularly. We recommend calibrating the
scales between each flock for maximum accuracy.
Select the "5. Installation" option from the main menu using the arrow
keys. Press the right-arrow key. Note that this menu is only available
from the installer mode (see sec. 5.6.1).
Select the "Calibration" menu using
the arrow keys. Press the right-arrow
key.
Select the desired scale using the ar-
row keys. Press the right-arrow key.
Enter the calibration weight using the
adjustment buttons.
Make sure the scale is stable and
empty before starting the calibration.
When the scale is stable and empty,
the message "Scale is: empty" is
displayed. Press for next step.
Wait until the message "Scale is :
Laden" is displayed. Put the calibra-
tion weight on the scale. It is recom-
mend to use a precision weight of
10kg ±250mg. Wait until the scale
becomes stable again. Press . The message "Scale is : Saved" is
then displayed for 1 minute. The scale calibration is now over. Follow
the same procedure for each activated scale.
Scale 2
Calib weight: 10000
Push + for next step
Scale is: Laden
5. Installation
3. Scale calibration
5.3 Scale
calibration
1. Scale 2
2. Scale 3
7
FEATHERWEIGHT BIRD SCALE rev.01
3. INSTALLATION
3.1 MOUNTING INSTRUCTIONS
Open the latch and lift the cover. Remove the black caps located on each of the
four mounting holes. Mount the enclosure on the wall using four screws. Be
sure the electrical knockouts are at the bottom of the enclosure in order to prevent
water from entering the controller. Insert the screws in the mounting holes and
tighten. Fasten the four black caps provided with the controller onto the four
mounting holes. The enclosure must be mounted in a location that will allow the
cover to be completely opened right up against the wall.
3.2 CONNECTIONS
To connect the controller, refer to the wiring diagram enclosed with this user's
manual. Use the electrical knockouts provided at the bottom of the enclosure.
Do not make additional holes in the enclosure, particularly on the side of the
enclosure when using a computer communications module.
All wiring must be done by an authorized electrician and must
comply with applicable codes, laws and regulations. Be sure power
is off before doing any wiring to avoid electrical shocks and
equipment damage.
Do not install rigid conduit into electrical knockouts. Only nylon
cable glands are permitted for cable or wire fastening.
The controller has no power-on switch. An external switch or circuit
breaker shall be included in the building installation to interrupt power
to L and N electric power lines. It shall be in close proximity to the
equipment and within easy reach of the operator. It shall be marked as
the disconnecting device for the equipment.
3.3 INTERNAL SWITCHES
The internal switches are located inside of the front
cover of the controller. When the controller is
shipped from the factory, all the switches are set to
OFF.
#FFONO
1SMARGSDNUOP
21-2DESUTON
ON
OFF
121110987654321