Intel SSR316MJ2 User manual

Intel®Storage System SSR316MJ2
Power Distribution Module (FMJPDB)
Installation Guide
Order Number: C75952-002

Disclaimer
Information in this document is provided in connection with Intel®products. No license, express or implied, by estoppel or
otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions
of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating
to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability,
or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or
authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of
the Intel product could create a situation where personal injury or death may occur. Intel may make changes to
specifications and product descriptions at any time, without notice.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright ©2004 - 2005 Intel Corporation. All Rights Reserved.

iii Intel®Storage System SSR316MJ2 Power Distribution Module
Important Safety Instructions
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
See Intel Server Boards and Server Chassis Safety Information at
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine
der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-
Serverplatinen und -Servergehäusen unter
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。
和/或http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的
Intel
Server Boards and Server Chassis Safety Information
(《Intel
服务器主板与服务器机箱安全信息》)。
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document
avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety
Information rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/CS-
010770.htm.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.

Intel®Storage System SSR316MJ2 Power Distribution Module iv
WARNINGS
Storage system power on/off: The push-button on/off power switch on the
front panel of the storage system does not turn off the AC power. To remove
AC power from the storage system, you must unplug the AC power cord
from either the power supply or wall outlet.
Hazardous conditions—power supply: Hazardous voltage, current, and
energy levels are present inside the power supply enclosure. There are no
user-serviceable parts inside the power supply; servicing should only be done
by technically qualified personnel.
Hazardous conditions—devices and cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the storage system and disconnect telecommunications systems,
networks, modems, and the power cord attached to the storage system before
opening it. Failure to do so can result in personal injury or equipment
damage.
Avoid injury: Lifting the storage system chassis and attaching it to the rack
is a two-person job. If needed, use an appropriate lifting device. A fully
loaded Intel®Storage System SSR316MJ2 weighs approximately 31.8 kg
(70 lbs.).
CAUTIONS
Temperature: The operating temperature of the storage system, when
installed in an equipment rack, must not go below 5° C (41° F) or rise above
35° C (95° F). Extreme fluctuations in temperature can cause a variety of
problems in the storage system.
Ventilation: The equipment rack must provide sufficient airflow to the front
of the storage system to maintain proper cooling. It must also include
ventilation sufficient to exhaust a maximum of 1900 BTUs per hour for a
fully loaded Intel®Storage System SSR316MJ2.

v Intel®Storage System SSR316MJ2 Power Distribution Module
Contents
About the Power Distribution Module............................................................... 7
Contents.................................................................................................................................. 7
Power Distribution Module Installation Procedures........................................ 8
Required Tools........................................................................................................................ 8
Power Down System and Remove Chassis Cover ................................................................. 8
Un-seat Power Supplies..........................................................................................................9
Remove Fan Assembly Screws ............................................................................................ 10
Disconnect Fan Cables ......................................................................................................... 11
Remove Fan Assembly ......................................................................................................... 12
Cut Cable Ties and Remove DIMM ...................................................................................... 13
Disconnect Power Distribution Module Cables ..................................................................... 14
Disconnect Cables and Remove Power Distribution Module................................................ 15
Install New Power Distribution Module.................................................................................. 16
Connect Cables and Install DIMM......................................................................................... 17
Connect Power Distribution Module Cables.......................................................................... 18
Install Fan Assembly............................................................................................................. 19
Attach Fan Assembly ............................................................................................................ 20
Connect System Fan Cables ................................................................................................ 21
Seat Power Supplies.............................................................................................................22
Finishing Up .......................................................................................................................... 23
Figures
Figure 1. Removing Chassis Cover ........................................................................................ 8
Figure 2. Un-seating the Power Supplies................................................................................ 9
Figure 3. Removing System Fan Assembly Screws ............................................................. 10
Figure 4. Disconnecting System Fan Cables ........................................................................ 11
Figure 5. Removing System Fan Assembly .......................................................................... 12
Figure 6. Cutting Cable Ties and Removing DIMM............................................................... 13
Figure 7. Disconnecting Power Distribution Module Cables ................................................. 14
Figure 8. Remove Power Distribution Module from System ................................................. 15
Figure 9. Installing the Power Distribution Module................................................................ 16
Figure 10. Connecting Cables and Installing DIMM.............................................................. 17
Figure 11. Connecting Power Distribution Module Cables.................................................... 18
Figure 12. Installing System Fan Assembly .......................................................................... 19
Figure 13. Attaching System Fan Assembly ......................................................................... 20
Figure 14. Connecting System Fan Cables .......................................................................... 21
Figure 15. Seating the Power Supplies................................................................................. 22
Figure 16. Installing the Chassis Cover ................................................................................ 23


Intel®Storage System SSR316MJ2 Power Distribution Module 7
About the Power Distribution Module
Enclosed is your new Intel®FMJPDB Power Distribution Module. The FMJPDB Power
Distribution Module is installed into the storage system directly behind the backplane board and the
backplane fan assembly, in front of the power supply.
This document describes how to install the FMJPDB Power Distribution Module into the Intel®
Storage System SSR316MJ2.
Contents
Intel®FMJPDB Power Distribution Module

8 Intel®Storage System SSR316MJ2 Power Distribution Module
Power Distribution Module Installation
Procedures
Required Tools
Cross-head (Number 1 size Phillips*) screwdriver, with a maximum length of 4 inches
Wire-cutter
Power Down System and Remove Chassis Cover
1. Review the safety information and warnings at the beginning of this guide.
2. Power down your Intel® Storage System Console. See letter “A” in Figure 1.
3. Remove both AC power cords from the AC power inputs at the rear of your storage system.
See letter “B” in Figure 1.
4. Loosen the two thumb screws at the rear of the chassis cover. See letter “C” in Figure 1.
5. Facing the front of the chassis, push the top cover rearward, and then lift it up to remove it. See
letter “D” in Figure 1.
A
D
B
C
C
TP01797
Figure 1. Removing Chassis Cover

Intel®Storage System SSR316MJ2 Power Distribution Module 9
Un-seat Power Supplies
1. For each power supply, press the latch the right side of the power supply module. See letter “A”
in Figure 2.
2. While pressing the latch, use the handle to pull the power supply out about one inch. See letter
“B” in Figure 2. It is not necessary to completely remove the power supply modules from the
bays.
TP01880
A
B
Figure 2. Un-seating the Power Supplies

10 Intel®Storage System SSR316MJ2 Power Distribution Module
Remove Fan Assembly Screws
Use a Number 1 size Phillips* screwdriver to remove the screw on each side of the system. See
letter “A” in Figure 3. These screws hold the system fan assembly in place. These screws will be re-
installed later.
A
TP01800
Figure 3. Removing System Fan Assembly Screws

Intel®Storage System SSR316MJ2 Power Distribution Module 11
Disconnect Fan Cables
1. Disconnect the Fan 3 cable from the server board. See letter “A” in Figure 4.
2. Disconnect the Fan 4 cable from the server board. See letter “B” in Figure 4.
3. Disconnect the Fan 5 cable from the server board. See letter “C” in Figure 4.
A
A
B
C
B
C
TP01801
Figure 4. Disconnecting System Fan Cables

12 Intel®Storage System SSR316MJ2 Power Distribution Module
Remove Fan Assembly
Simultaneously pull up on both sides of the system fan assembly to remove the fan assembly from
the storage system. See letter “A” in Figure 5.
A
A
TP01885
Figure 5. Removing System Fan Assembly

Intel®Storage System SSR316MJ2 Power Distribution Module 13
Cut Cable Ties and Remove DIMM
1. Cut the plastic cable ties that bundle the power distribution cables. These ties hold the power
distribution cables against the edge of the system. See letter “A” in Figure 6.
2. Push down the clips at each side of the DIMM connector that is the closest to the wire
connections on the server board. See letter “B” in Figure 6.
3. Lift up on the DIMM to remove it. See letter “C” in Figure 6. Place the DIMM on a static free
surface.
A
BB
C
TP01881
Figure 6. Cutting Cable Ties and Removing DIMM

14 Intel®Storage System SSR316MJ2 Power Distribution Module
Disconnect Power Distribution Module Cables
Disconnect the two 12-pin power distribution module connectors from the backplane board. See
letter “A” in Figure 7.
A
TP01805
Figure 7. Disconnecting Power Distribution Module Cables

Intel®Storage System SSR316MJ2 Power Distribution Module 15
Disconnect Cables and Remove Power Distribution
Module
1. Disconnect the 8-pin cable from the server board. See letter “A” in Figure 8.
2. Disconnect the 24-pin cable from the server board. See letter “B” in Figure 8.
3. Disconnect the 5-pin cable from the server board. See letter “C” in Figure 8.
4. Press down on the lever at the front of the power distribution module. While holding the lever
down, remove the power distribution module from the system. See letter “D” in Figure 8.
Figure 8. Remove Power Distribution Module from System

16 Intel®Storage System SSR316MJ2 Power Distribution Module
Install New Power Distribution Module
1. Position the new power distribution module near the installation location in the system. See
letter “A” in Figure 9.
2. Press down on the lever at the front of the power distribution module. While holding the lever
down, slide the new power distribution module into place. Ensure that the power distribution
module snaps into its seated position. See letter “C” in Figure 9.
3. Insert new plastic cable ties through the two steel links on the side of the chassis. Wrap the
plastic cable ties around the power distribution cables and pull the ties tight around the cables.
See letter “B” in Figure 9.
A
C
B
Figure 9. Installing the Power Distribution Module

Intel®Storage System SSR316MJ2 Power Distribution Module 17
Connect Cables and Install DIMM
1. Connect the 8-pin cable to the server board. See letter “A” in Figure 10.
2. Connect the 24-pin cable to the server board. See letter “B” in Figure 10.
3. Connect the 5-pin cable to the server board. See letter “C” in Figure 10.
4. Position the DIMM above the socket. Align the two small notches in the bottom edge of the
DIMM with the keys in the socket. See letter “D” in Figure 10.
5. Insert the bottom edge of the DIMM into the socket.
6. Push down on the top edge of the DIMM until the retaining clips snap into place. Make sure the
clips are firmly in place. See letter “E” in Figure 10.
TP01883
Figure 10. Connecting Cables and Installing DIMM

18 Intel®Storage System SSR316MJ2 Power Distribution Module
Connect Power Distribution Module Cables
Connect the two 12-pin power distribution module cables to the backplane board. See letter “A” in
Figure 11.
A
TP01808
Figure 11. Connecting Power Distribution Module Cables

Intel®Storage System SSR316MJ2 Power Distribution Module 19
Install Fan Assembly
1. Move loose wires away from the space where the system fan assembly will be installed.
2. Align the holes on the bottom edge of the system fan assembly with the blue plastic shock
brackets on the bottom of the chassis.
3. Set the system fan assembly into place. See letter “A” in Figure 12.
A
A
TP01811
Figure 12. Installing System Fan Assembly

20 Intel®Storage System SSR316MJ2 Power Distribution Module
Attach Fan Assembly
Use a Number 1 size Phillips screwdriver to attach the fan assembly to the chassis, using one screw
at each side of the system. See letter “A” in Figure 13.
A
TP01812
Figure 13. Attaching System Fan Assembly
Other manuals for SSR316MJ2
6
Table of contents
Other Intel Network Storage Server manuals