1. Please cut off the power and clean the shell with natural detergent
when it is dirty. The acid and alkalescent bathroom detergent and BEN,
lacquer thinner, abrasive, etc. are forbidden. Also, do not use nylon
brush to avoid scratching;
2. When cleaning the shell prevent the water droplets getting into the
machine so as to avoid electric shock or short circuit;
3. It's better to cut off the power when off duty to extend the service life;
4. If the power cord is damaged, it should be replaced by the
manufacturer, its service agents or similar qualified person;
5. If the machine breaks down, cut off the power; please commission a
professional to repair it.
1. The product guarantee period is 3 years.
2. The guarantee period for products came into effect from
the date of buying the machine.
3. The following are not covered by the guarantee:
Improper use and the fault caused by demolition, alteration
and repair by technical persons without our company
authorisation.
Fires, earthquakes, thunder and other natural disasters
causing faults, and abnormal voltage.
The faults caused by non matching power.
The faults caused by long time operation in bad working
condition.
Attention: If the air flow becomes weaker, please
clean the filter screen. Do not use water.
Unlock the filter screen and use
the ridge in the middle of the
filter cartridge to pull and remove.
Get the filter from
the filter cartridge.
Put the filter at the right
position in the filter
cartridge, and insert the
filter cartridge into the
body.
Clean the dust on the filter, do not wash.
If there is too much dust, please replace its filter.
1. It is equipped with an automatic infrared ray induction system,
which means you do not have to touch the unit at any time, so this
effectively avoids pathogen cross infection and re-contamination.
2. It has outstanding performance with advanced technology and
infrared sensor.
3. It has a high speed motor with RPM of 24,000.
4. This product comes with over current protection.
5. Easy to install. It is suitable for schools, factories, office buildings,
hotels and similar locations.
Air Speed
Air outlet
1. Do not install it above stainless steel or other shining surface location,
otherwise prone to misoperation.
2. The body should be firmly fixed to the smooth wall to avoid injuries caused
by the decline of product or product damage.
3. Do not install the products in such place with corrosivevor flammable gases
or objects, it may cause fire or product failure and malfunction.
4. Do not install the products in such environment with multi dust or in high
temperature, it may cause product damage.
1. Do not fix in locations where the unit is likely to be splashed by excessive
water in order to avoid electric shock.
2. You must commission a professional electrician to install or else it has
electric shock hazard.
3. You must cut off power before installation and maintenance.
4. Do not dismantle, repair or make alterations to this machine without
authorisation, otherwise there is a risk of electric shock, fire and other
accidents.
10 - 15 sec.

3Intelligent Facility Solutions
Dear customer:
Thanks for your purchase. Please read these
instructions before installation and keep it
for installation and usage or any other
further reference.
1. Please cut off the power and clean the shell with natural detergent
when it is dirty. The acid and alkalescent bathroom detergent and BEN,
lacquer thinner, abrasive, etc. are forbidden. Also, do not use nylon
brush to avoid scratching;
2. When cleaning the shell prevent the water droplets getting into the
machine so as to avoid electric shock or short circuit;
3. It's better to cut off the power when off duty to extend the service life;
4. If the power cord is damaged, it should be replaced by the
manufacturer, its service agents or similar qualified person;
5. If the machine breaks down, cut off the power; please commission a
professional to repair it.
1. The product guarantee period is 3 years.
2. The guarantee period for products came into effect from
the date of buying the machine.
3. The following are not covered by the guarantee:
Improper use and the fault caused by demolition, alteration
and repair by technical persons without our company
authorisation.
Fires, earthquakes, thunder and other natural disasters
causing faults, and abnormal voltage.
The faults caused by non matching power.
The faults caused by long time operation in bad working
condition.
Attention: If the air flow becomes weaker, please
clean the filter screen. Do not use water.
Unlock the filter screen and use
the ridge in the middle of the
filter cartridge to pull and remove.
Get the filter from
the filter cartridge.
Put the filter at the right
position in the filter
cartridge, and insert the
filter cartridge into the
body.
Clean the dust on the filter, do not wash.
If there is too much dust, please replace its filter.
1. It is equipped with an automatic infrared ray induction system,
very easy to use, reducing waste, and no touching, which
effectively avoids pathogen cross infection and re-contamination.
2. It has outstanding performance with most advantage chip
control technology and infrared sensor.
3. It has unified high speed motor with RPM of 24,000.
4. This series product comes with over current protection, which
effectively eliminates accidents.
5. Easy to install. It is suitable for all departments in hospitals,
school, food and pharmaceutical manufacturers, airports, office
buildings, hotels, government agencies and research
institutions and other places.
Air Speed
Air outlet
1. Do not install above stainless steel or other locations with reflective surfaces, otherwise
the unit will be prone to self-operating.
2. The unit should be firmly fixed to a smooth, completely flat wall.
3. A minimum distance of 100mm should be left clear either side of the unit.
4. Avoid locations where people or doors might damage the unit.
5. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, unless they are supervised and instructed how to use the
appliance by the person responsible for their safety.
1. Do not install in the following places as this may cause the unit to malfunction and cause
accidents: - In areas with temperatures below 10°C or above 40°C.
- Where the unit is likely to be splashed by water or can get excessively wet.
- In direct sunlight.
- In an area where there is condensation.
- In an area close to chemicals or gases.
- In altitude over the range of 0-2000m.
2. You must cut off the power before installation and maintenance.
3. Do not dismantle, repair or make alterations to this machine without authorisation, otherwise
there is a risk of electric shock, fire and other accidents.
4. The machine must have an earth connection.
5. If the power is over +/-10% the unit will malfunction. Using an incorrect power supply will
invalidate the guarantee.
Sensor
Mounting plate
Air intake grille
Filter
Components:

Dryflow Viper 4
Dear customer:
Thanks for your purchase. Please read these
instructions before installation and keep it
for installation and usage or any other
further reference.
1. Please cut off the power and clean the shell with natural detergent
when it is dirty. The acid and alkalescent bathroom detergent and BEN,
lacquer thinner, abrasive, etc. are forbidden. Also, do not use nylon
brush to avoid scratching;
2. When cleaning the shell prevent the water droplets getting into the
machine so as to avoid electric shock or short circuit;
3. It's better to cut off the power when off duty to extend the service life;
4. If the power cord is damaged, it should be replaced by the
manufacturer, its service agents or similar qualified person;
5. If the machine breaks down, cut off the power; please commission a
professional to repair it.
1. The product guarantee period is 3 years.
2. The guarantee period for products came into effect from
the date of buying the machine.
3. The following are not covered by the guarantee:
Improper use and the fault caused by demolition, alteration
and repair by technical persons without our company
authorisation.
Fires, earthquakes, thunder and other natural disasters
causing faults, and abnormal voltage.
The faults caused by non matching power.
The faults caused by long time operation in bad working
condition.
Attention: If the air flow becomes weaker, please
clean the filter screen. Do not use water.
Unlock the filter screen and use
the ridge in the middle of the
filter cartridge to pull and remove.
Get the filter from
the filter cartridge.
Put the filter at the right
position in the filter
cartridge, and insert the
filter cartridge into the
body.
Clean the dust on the filter, do not wash.
If there is too much dust, please replace its filter.
1. It is equipped with an automatic infrared ray induction system,
very easy to use, reducing waste, and no touching, which
effectively avoids pathogen cross infection and re-contamination.
2. It has outstanding performance with most advantage chip
control technology and infrared sensor.
3. It has unified high speed motor with RPM of 24,000.
4. This series product comes with over current protection, which
effectively eliminates accidents.
5. Easy to install. It is suitable for all departments in hospitals,
school, food and pharmaceutical manufacturers, airports, office
buildings, hotels, government agencies and research
institutions and other places.
Air Speed
Air outlet
1. Do not install it above stainless steel or other shining surface location,
otherwise prone to misoperation.
2. The body should be firmly fixed to the smooth wall to avoid injuries caused
by the decline of product or product damage.
3. Do not install the products in such place with corrosivevor flammable gases
or objects, it may cause fire or product failure and malfunction.
4. Do not install the products in such environment with multi dust or in high
temperature, it may cause product damage.
1. Do not fix in locations where the unit is likely to be splashed by excessive
water in order to avoid electric shock.
2. You must commission a professional electrician to install or else it has
electric shock hazard.
3. You must cut off power before installation and maintenance.
4. Do not dismantle, repair or make alterations to this machine without
authorisation, otherwise there is a risk of electric shock, fire and other
accidents.

5Intelligent Facility Solutions
Dear customer:
Thanks for your purchase. Please read these
instructions before installation and keep it
for installation and usage or any other
further reference.
1. Please cut off the power and clean the shell with natural detergent
when it is dirty. The acid and alkalescent bathroom detergent and BEN,
lacquer thinner, abrasive, etc. are forbidden. Also, do not use nylon
brush to avoid scratching;
2. When cleaning the shell prevent the water droplets getting into the
machine so as to avoid electric shock or short circuit;
3. It's better to cut off the power when off duty to extend the service life;
4. If the power cord is damaged, it should be replaced by the
manufacturer, its service agents or similar qualified person;
5. If the machine breaks down, cut off the power; please commission a
professional to repair it.
1. The product guarantee period is 3 years.
2. The guarantee period for products came into effect from
the date of buying the machine.
3. The following are not covered by the guarantee:
Improper use and the fault caused by demolition, alteration
and repair by technical persons without our company
authorisation.
Fires, earthquakes, thunder and other natural disasters
causing faults, and abnormal voltage.
The faults caused by non matching power.
The faults caused by long time operation in bad working
condition.
Attention: If the air flow becomes weak, please
clean the filter. Do not use water.
Unlock the filter grille and use
the ridge in the middle of the
filter grille to pull and remove.
Get the filter from
the filter grille.
Put the filter at the right
position in the filter
grille, and insert the
filter grille back onto the
unit, making sure to turn
Clean the dust on the filter, do not wash.
If there is too much dust, please replace the filter.
1. It is equipped with an automatic infrared ray induction system,
very easy to use, reducing waste, and no touching, which
effectively avoids pathogen cross infection and re-contamination.
2. It has outstanding performance with most advantage chip
control technology and infrared sensor.
3. It has unified high speed motor with RPM of 24,000.
4. This series product comes with over current protection, which
effectively eliminates accidents.
5. Easy to install. It is suitable for all departments in hospitals,
school, food and pharmaceutical manufacturers, airports, office
buildings, hotels, government agencies and research
institutions and other places.
Air Speed
Air outlet
1. Do not install it above stainless steel or other shining surface location,
otherwise prone to misoperation.
2. The body should be firmly fixed to the smooth wall to avoid injuries caused
by the decline of product or product damage.
3. Do not install the products in such place with corrosivevor flammable gases
or objects, it may cause fire or product failure and malfunction.
4. Do not install the products in such environment with multi dust or in high
temperature, it may cause product damage.
1. Do not fix in locations where the unit is likely to be splashed by excessive
water in order to avoid electric shock.
2. You must commission a professional electrician to install or else it has
electric shock hazard.
3. You must cut off power before installation and maintenance.
4. Do not dismantle, repair or make alterations to this machine without
authorisation, otherwise there is a risk of electric shock, fire and other
accidents.
Cleaning of Filter
the lock to secure in place.
The air filter must be installed
when operating the unit.

Dryflow Viper 6
Dear customer:
Thanks for your purchase. Please read these
instructions before installation and keep it
for installation and usage or any other
further reference.
1. Please cut off the power and clean the cover with neutral detergent using
a clean soft dry cloth when it is dirty. Do not use solvents, acid or alkaline
cleaners or hard brushes as these can damage the machine surface or cause
it to discolour;
2. When cleaning the cover prevent water droplets getting into the machine
to avoid electric shock or short circuit;
3. If the power cord is damaged, it must be replaced by the manufacturer,
its service agents or similar qualified person;
4. If the machine breaks down, cut off the power; please commission a
professional to repair it.
1. The product guarantee period is 3 years.
2. The guarantee period came into effect from the date of buying
the machine.
3. The following are not covered by the guarantee:
Improper use and fault caused by demolition, alteration
and repair by persons not technically qualified.
Fires, earthquakes, thunder and other natural disasters
causing faults and abnormal voltage.
Faults caused by non matching power.
Faults caused by excessive use in non optimal operating conditions.
Attention: If the air flow becomes weaker, please
clean the filter screen. Do not use water.
Unlock the filter screen and use
the ridge in the middle of the
filter cartridge to pull and remove.
Get the filter from
the filter cartridge.
Put the filter at the right
position in the filter
cartridge, and insert the
filter cartridge into the
body.
Clean the dust on the filter, do not wash.
If there is too much dust, please replace its filter.
1. It is equipped with an automatic infrared ray induction system,
very easy to use, reducing waste, and no touching, which
effectively avoids pathogen cross infection and re-contamination.
2. It has outstanding performance with most advantage chip
control technology and infrared sensor.
3. It has unified high speed motor with RPM of 24,000.
4. This series product comes with over current protection, which
effectively eliminates accidents.
5. Easy to install. It is suitable for all departments in hospitals,
school, food and pharmaceutical manufacturers, airports, office
buildings, hotels, government agencies and research
institutions and other places.
Air Speed
Air outlet
1. Do not install it above stainless steel or other shining surface location,
otherwise prone to misoperation.
2. The body should be firmly fixed to the smooth wall to avoid injuries caused
by the decline of product or product damage.
3. Do not install the products in such place with corrosivevor flammable gases
or objects, it may cause fire or product failure and malfunction.
4. Do not install the products in such environment with multi dust or in high
temperature, it may cause product damage.
1. Do not fix in locations where the unit is likely to be splashed by excessive
water in order to avoid electric shock.
2. You must commission a professional electrician to install or else it has
electric shock hazard.
3. You must cut off power before installation and maintenance.
4. Do not dismantle, repair or make alterations to this machine without
authorisation, otherwise there is a risk of electric shock, fire and other
accidents.

Intelligent Facility Solutions Ltd
Electric Works
3 Concourse Way
Sheffield
S1 2BJ
+44 (0)114 354 0047
service@ihdryers.co.uk
intelligenthanddryers.com
Table of contents
Other Intelligent Dryer manuals
Popular Dryer manuals by other brands

Whirlpool
Whirlpool HybridCare WED9290F Use & care guide

GE
GE Spacemaker DSXH43D owner's manual

AEG
AEG LAVATHERM 56600 operating instructions

Mediclinic
Mediclinic E05 Installation and operating manual

Bosch
Bosch WQG24200GC User manual and installation instructions

Whirlpool
Whirlpool Duet W10182361A Use and care guide