Inter-m RFA-102 User manual

Operation Manual
(Webpage Setting)
Receiver for AOE
RFA-102

RECEIVER FOR AOE
Content
Content
Webpage Setting............................................................................................................................1
Ⅰ. Initial Web network setup..............................................................................................................1
Ⅱ. Main Menu S reen ......................................................................................................................2
Ⅱ. 1 RFA-Conne tion Setup...........................................................................................................3
Ⅱ. 2 RFA-Conta t losure Setup.....................................................................................................4
Ⅱ. 3 Network Setup......................................................................................................................5
Ⅱ. 4 Time Setup ...........................................................................................................................6
Ⅱ. 5 View log ..............................................................................................................................7
Ⅱ. 6 System management .............................................................................................................8

RECEIVER FOR AOE
1
RFA-102
Webpage Setting
Webpage Setting
Ⅰ. Initial Web network etup
①INTIAL SETTING INFORMATION OF THE NETWORK EQUIPMENT
②REQUIRED EQUIPMENTS
- Use any network and browser enabled devi e su h as a PC or tablet to onne t to the Web browser of the
RFA-102.
③HOW TO SET UP
a. Conne t the RFA-102 to a network and browser enabled devi e using a straight or ross network able.
b. You an also onne t via a network router or swit h.
. Set the network onfiguration of the RFA-102 and the network devi e.
※Disable the wireless network if your.
※Contents of this Operation Manual are subje ted to be hanged by revision of firmware, please refer
to www.inter-m. om/en for latest one.
DHCP NO IP Address 192.168.1.99
Netmask 255.255.255.0 Gateway 192.168.1.1
DNS1 192.168.32.130 DNS2 192.168.32.132

RECEIVER FOR AOE
2RFA-102
d. From the network devi e browser (Internet Explorer, Chrome, et ) enter the IP address of the RFA-100 in
address bar of the internet browser.
e. When prompted to enter the a ess ID and password, enter the initially set values.
(userid: admin, password:1)
f. Cli k the Network Settings menu in the left Navigation pane to onfigure the network setting of the
RFA-102.
Ⅱ. Main Menu Screen
Above is Default s reen view when first onne ted to the Web page of the equipment.
①Devi e name.
②Sele t language of the web pages. (Korean / English)
③Displays the information of web onne ted devi e. (Devi e Name/Devi e IP/Web Version)
④Navigation menu pane.
⑤When a topi is sele ted in any area, the ontent of that topi appear in this area.
Problems onne ting?
①Make sure the able is in good working order.
②Make sure that you are able to “ping” the RFA-102 from the network devi e.
(If there is no response, rework the network onfiguration)
③Make sure equipment is turned on.

RECEIVER FOR AOE
3
RFA-102
Ⅱ. 1 RFA-Connection Setup
Above is a s reen display when “RFA-Conne tion Setup” menu is li ked.
①Sele t transmission method for re eption. The produ t operates when set same with mode of the server
devi e (AOE-212N)
②Sele t se ondary server to onfigure the redundan y of the streaming server. The produ t onne ts to the
sub server when dis onne ted due to having problems with the main server.
③Sele t buffering time when first a essed. The initial value is set to 0 se onds. A smaller value redu es the
wait time or laten y,whereas the larger the value the longer is the wait time or laten y.Ahigher buffer
ratio will in rease the stream stability and redu e dropouts usually related to network traffi .
④Sele t IP address and port number of the main server. By sele ting dual server operation of ②, inserting IP
address and port number of the sub server is available.
⑤Sele t <Start> to onne t the Main-Server and begin streaming and sele t <stop> toend streaming.
⑥Cli k [Apply] button to apply the modified setting.
Cli k [Initialize] button to reset to the previous data setting.
⑦Displays Help & Tips on RFA-Conne tion Setup.

RECEIVER FOR AOE
4RFA-102
Ⅱ. 2 RFA-Contact clo ure Setup
Above is a s reen display when “RFA-Conta t losure Setup” menu is li ked.
①Sele t onta t servi e operation status.
②Sele ting onta t ontrol number for re eption of onta t information is a essible with sub devi e. Only
within the sele ted onta t ontrol number, the ommand is applied.
③Reset stands for the default of onta t losure when the servi e stops.
④In ase the onta t losure a tives, the operating of onta t losuredelays.
Maximum delay up to 9 se onds 900 milise onds.
⑤It des ribes the prevention of downtime of servi e and dispersion ofservi e load. When the main server
breaks down, it swit hes to theredundan y server.
⑥IP address: Conne t to the server with the preset IP address to onne tserver.
Port: Put the port number related to the server to onne t.
⑦Cli k [Apply] button to apply the modified setting.
Cli k [Initialize] button to reset to the previous data setting.
※Audio annot be played when onta t signal is re eived from set onta t number.

RECEIVER FOR AOE
5
RFA-102
Ⅱ. 3 Network Setup
Above is a s reen display when “Network Settings” menu is li ked. In this display, MAC address,
IPinformation, host name an be seen and be hanged.
①The MAC address of the devi e is displayed.
②Host name of the onfigured devi e is displayed and an also be modified.
③Displays the IP information as applied to the devi e and the user an modify the IP information.
④Cli k [Apply] button to apply the modified setting.
Cli k [Initialize] button to reset to the previous data setting.
⑤Displays Help & Tips on Network setup.

RECEIVER FOR AOE
6RFA-102
Ⅱ. 4 Time Setup
Above is a s reen display when “Time Setup” menu is li ked.
①The default time zone is (GMT+09:00) Seoul. Sele t a orre t time zone in the box a ording to your
geographi al zone.
②Displays the urrent date and time.
③Time Setup
a. Manual Setup
RFA-102 uses internal lo k to make time so that its time has some drift from the orre t time. It
isneeded to adjust the time regularly.
b. Automati Time Syn hronization
It syn hronizes the time from the time server so that RFA-102 an maintain the orre t time.
The default time server is time.bora.net.
④Cli k [Apply] button to apply the modified setting.
⑤Displays Help & Tips on Time Setup.

RECEIVER FOR AOE
7
RFA-102
Ⅱ. 5 View log
Above is a s reen display when “View Log” menu is li ked.
①This page displays the log informationof the RFA-102 setting and history of modifi ation with time.
②[Refresh] button-the urrent log details will be renewed.
[Clear Log] button-the urrent log details will be deleted.
③Displays Help&Tips on View log.

RECEIVER FOR AOE
8RFA-102
Ⅱ. 6 Sy tem management
Above is a s reen display when “System management” menu is li ked.
①Two types of upgrade (software and mainboard) are available.
②Change the password to onne t to the web page of the equipment.
③Restart will reboot the system.
④Fa tory set will initialization the system.

9
RFA-102
NOTE

MADE IN KOREA
October 2015 M100018
Inter-M, Ltd. (Korea) began operations in 1983.
Sin e then, Inter-M has grown to be ome one of the largest manufa turers
of professional audio and ommer ial sound ele troni s equipment in the world.
Inter-M has gained worldwide re ognition for its own branded produ ts,
as well as private label manufa turing of ele troni s sold under other names (OEM).
The ompany is no longer just a Korean ompany, but rather a global ompany
that is truly international in s ope, with fa tories and offi es in Korea and China,
and sales and marketing operations lo ated in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M America , INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA
TEL : +1-562-921-0313, FAX : +1-562-921-0370
Home Page : http://www.inter-m.net, E-mail : [email protected]
Inter-M Corporation
SEOUL OFFICE : 719, DOBONG-RO, DOBONG-GU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
Home Page : http://www.inter-m. om, E-mail : overseas@inter-m. om
Other manuals for RFA-102
1
Table of contents
Other Inter-m Receiver manuals