Recommended DMX-512 Cable Types
CAT5E or CAT6
White/Brown =DMX Ground (Black)
Orange =DMX Data - (Brown)
White/Orange =DMX Data + (Red)
Others =Unused
Belden 9842
Drain Wire =DMX Ground (Black)
Blue/White =DMX Data - (Brown)
White/Blue =DMX Data + (Red)
Orange/White =Unused
White/Orange =Unused
Other similar 100-120 ohm twisted-pair
RS-485 compatible computer
communication cable may be used.
Interactive Technologies, Inc.
5040 Magnolia Creek Drive
Cumming, GA 30028 USA
678-455-9019 (Phone) • 678-455-9071 (Fax)
www.interactive-online.com
Drawn By: Rob Johnston
Date: 11/20/2012
Checked: Rob Johnston
Scale: 1:1
Units: Millimeters [Inches]
Revision
B
D0316: SceneStation Typical Wiring Diagram
DMX-512 Port
DMX Ground (Black)
DMX Data - (Brown)
DMX Data + (Red)
Optional DMX Input
Connect to First DMX Fixture,
Dimmer or Power Supply. DMX
signals then daisy-chain through
each unit.
DMX Output
Optional input from DMX
console or controller.
Power Input
(Non-Polarized)
SceneStation
Model SS-305
Class 2 Power Supply
11-28 VDC (5W minimum)
14-28 VAC (5VA minimum)
Optional Remote Station
DMX Output
(optional)
One or more remote stations may
connect to a master station via
2.4GHz wireless link.
* See table for
recommended
DMX cable types.
DMX Input Note:
SceneStation uses a bi-directional DMX
Port for both DMX Input and Output. If no
Input DMX signal is detected, SceneStation
will output a DMX signal. If an Input signal
is detected (from another console or
controller), SceneStation will automatically
go into "passive" mode, which allows the
upstream controller to be in full control of
the DMX fixtures. SceneStation also uses
this mode to record DMX scenes from the
external source.
18-22 AWG
2-Conductor
Electrical Box
Power Supply
Power