Inventus Power SBM-01 User manual

inventuspower.com
info@inventuspower.com
+1 877.423.4242
Inventus Power, Inc.
1200 Internationale Parkway
Woodridge, IL 60517
Designed & Manufactured by
Smart Battery Monitor
User Manual
SBM-01

2
PROformance Add-On Device
User Manual
Applicable Models
Document Information
Inventus Power® is a trademark of Inventus Power.
Copyright© 2023 Inventus Power All rights reserved.
Technical Support
If you have any technical questions regarding the PROformance Add-On Device, please
contact our technical support team at:
Phone: +1.877.423.4242
E-mail: tech_support@inventuspower.com
Release Date Revision Scope of Change
2023-03-15 V1.4 Minor edits to V1 release
Model Part Number
U1LiFePROTM Smart Battery Monitor Kit 903-09472-001
PROTRXionTM 48V60-TRX-HD Smart Battery Monitor Kit 903-09472-002
PROTRXionTM 24V80 24V90 36V80 48V60 Smart Battery Monitor Kit 903-09472-003
PROTRXionTM 12V100-TRX-HD 24V60 Smart Battery Monitor Kit 903-09472-004
PROTRXionTM 48V60 (Old Pinout) Smart Battery Monitor Kit 903-09472-005

3
Contents
Introduction .................................................................................................................................... 4
Safety and Tools ............................................................................................................................ 4
Installation Guide .......................................................................................................................... 5
Operating Guide ........................................................................................................................... 8
Pin Definition ................................................................................................................................ 10
Mechanical Specifications ........................................................................................................ 10

4
Introduction
Thank you for choosing Inventus Power, the leading provider of advanced battery and power
systems for global OEMs.
The SBM-01 is a intelligent battery monitor, specifically designed to complement Inventus
Power PROformance batteries with an operating voltage range between 9 - 60VDC. With
integrated intelligence, the Smart Battery Monitor can receive data from the battery system
to communicate battery health, critical battery data, as well as indicate low battery capacity
(Limp Home Notification), so the system can return safely back to a charging station.
We’ve made the SBM-01 easy to install and intuitive to setup.
• Quick installation and set up
• For step-by-step instructions, refer to this manual for easy-to-follow directions
• Need more help? Contact Tech_Support@inventuspower.com or +1.877.423.4242
Safety and Tools
Before working with any electrical products or where electricity is present, the
following guidelines are required:
• Turn o system power, disconnect battery, and place battery in ship mode
• Proper PPE (Personal Protective Equipment)
• Rubber gloves
• Safety glasses
• Removal of any jewelry
Tools Needed
• Drill and 51mm hole cutter
• Hand saw
• Insulated torque wrench
• Insulated Philips Screwdriver (optional)
• Sandpaper

5
Mounting Hole
NOTCH TO SECURE MONITOR
(5.5mm WIDE x 4.5mm)
CABLE
ALIGNMENT KEY
(5.14mm x 4.2mm)
CLEARANCE HOLE
(Ø51.7 ± 0.2MM)
1. Insert Smart Monitor threaded body through clearance hole (51.7±0.2mm) using alignment
key with notch (reference note above for creating clearance hole)
2. Secure monitor with nut and tighten to 3 Nm torque
3. Attach 8-pin Cable to Rear of Smart Monitor (reference pages 6-8 for specific battery model
and wire harness part number)
Note: A hole will need to be cut if the existing panel does not include a 51.7mm diameter hole.
1. Using a drill with a 51mm hole cutter, cut hole (Note: if the SBM-01 cannot be inserted
through the clearance hole easily, the hole can be increased using the sandpaper)
2. Locate top of hole, mark desired location to cut alignment notch
3. Using a handsaw, cut a 5.5mm x 4.5mm notch as shown in above figure
Installation
Ø51.7±0.2 mm
5.5±0.2 mm 4.5±0.2 mm

6
Cable Installation
Smart Battery Monitor SKU P/N: 903-09472-003
Applicable Battery Models:
Smart Battery Monitor SKU P/N: 903-09472-005
Reference above image
Applicable Battery Models:
M-48V60-TRX†
S-48V60-TRX†
S-36V80-TRX*
M-36V80-TRX*
S-48V60-TRX*
M-48V60-TRX*
Connection Steps:
1. Connect battery M12 signal port to cable harness
(See battery user manual for proper installation).
2. Connect Smart Battery Monitor to 8-pin connector.
*Proceed to steps 3-5 only if applicable (for 36V and 48V batteries only).
3. Connect 4-pin connector on wire harness to 4-pin connector on ring terminal harness.
4. Connect black wire M8 ring terminal to negative terminal on the battery (See battery user
manual for proper installation).
5. Connect red wire M10 ring terminal to positive terminal on the battery (See battery user
manual for proper installation).
1. Connect battery M12 signal port to cable harness
(See battery user manual for proper installation).
2. Connect Smart Battery Monitor to 8-pin connector.
3. Connect 4-pin connector on wire harness to 4-pin connector on ring terminal harness.
4. Connect black wire M8 ring terminal to negative terminal on the battery (See battery user
manual for proper installation).
5. Connect red wire M10 ring terminal to positive terminal on the battery (See battery user
manual for proper installation).
† This SKU is compatible only with older models of S/M-48V60-TRX (MFG Date before March 1, 2023) where pin 6 is auxilary
power
Not to scale
1
3
2
4
5
1.8m1.8m
S-24V80-TRX
M-24V80-TRX
S-24V90-TRX
M-24V90-TRX

7
Smart Battery Monitor SKU P/N: 903-09472-002
Applicable Battery Models:
M-48V60-TRX-HD
S-48V60-TRX-HD
1. Connect battery signal port to cable harness (See battery user manual for proper installation).
2. Connect Smart Battery Monitor to 8-pin connector
1 2
2.0m2.0m
Not to scale
Smart Battery Monitor SKU P/N: 903-09472-004
Applicable Battery Models:
S-12V100-TRX-HD
M-24V60-TRX
S-24V60-TRX
Connection Steps:
1. Connect battery M12 signal port to cable harness
(See battery user manual for proper installation).
2. Connect black wire M8 ring terminal to negative terminal on the battery (See battery user
manual for proper installation).
3. Connect red wire M8 ring terminal to positive terminal on the battery (See battery user
manual for proper installation).
4. Connect Smart Battery Monitor to 8-pin connector.
4
1
2
3
1.8m1.8m
Not to scale

8
Smart Battery Monitor SKU P/N: 903-09472-001
Applicable Battery Models:
M-12V40-U1
S-12V40-U1
M-24V20-U1
S-24V20-U1
1. Connect battery RJ-45 signal port to cable harness
(See battery user manual for proper installation).
2. Connect black wire M6 ring terminal to negative terminal on the battery (See battery user
manual for proper installation).
3. Connect red wire M6 ring terminal to positive terminal on the battery (See battery user
manual for proper installation).
4. Connect Smart Battery Monitor to 8-pin connector.
4
1
3
2
1.8m1.8m
Not to scale
Operating SBM-01
1. Display
2. MODE Button
• Activates display while in shutdown or sleep mode
• Shuts down monitor when pressed for 3 secs
• Toggle between Home Screen and Status Screen
Once the monitor is installed, powered up, and establishes communication with the battery, the
Startup Screen will be displayed for 3 seconds, followed by the Home Screen. To shutdown the
monitor, hold the MODE button for 3 seconds.
1
2

9
The monitor will go to sleep after 5 minutes of battery inactivity and the display will turn o. To
activate the display, tap the MODE button.
Note: Reference Battery User Manual and Battery Software User Guide for more information
on fault codes displayed by the Smart Battery Monitor.
Get To Know Your Smart Monitor Display Settings
Startup Screen Home Screen Status Screen
• Battery State of Health
displayed for 3 seconds
• Battery charging icon
(only in charge mode)
• State of Charge (%)
• Battery Runtime Remaining
• Battery Voltage (V)
• Battery Fault Alert (only
appears when there is a fault)
• ERROR: Battery Fault Code
• BATT TEMP: Battery
Temperature (°C)
• LIFE AH USED: Cumulative
lifetime discharge capacity
(Ah)
• CURRENT: Charge/Discharge
Current (A)
• SW VER: Battery Software
Version [BQ, ATSAM, SBM-01]
Battery Sleep Screen Limp Home Screen
• Indicates the battery is in
Sleep Mode.
• Operate the system to wake
up the battery and re-
establish communication with
the Smart Battery Monitor.
• Indicates the battery has low
State of Charge and should
be charged.

10
Connector Pin Definition
Pin Signal Description
1 CANH CANbus high signal
2 CANL CANbus low signal
3 Aux Power Auxiliary Power
4 Ground Ground
5 B+ Battery Positive
6 B- Battery Negative
7 Sense - Sense Negative
8 Sense + Sense Positive
PIN 8
PIN 4
PIN 5
PIN 1
Mechanical Dimensions (SBM-01)
All dimensions are in millimeters. For tolerances and inches, please reference datasheet.
Need More Help?
Contact Tech_Support@inventuspower.com
+1.877.423.4242
19.4
(VIEWING AREA)
29.0
(VIEWING AREA)
60
7.4 30.0
56.000
43.1
51.2
4.9
4.3
UNRELEASED DRAFT
FOR PROTOTYPING ONLY
REVISIONS
REV.
DESCRIPTION
DATE
ECN
AUTHOR
CHECKED
BY
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
CREATED
DATE
NAME
SIZE
B
PART NO.
REV
1 OF 1
SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
--
--
THIS DOCUMENT AND ANY ASSOCIATED DATA CONTAIN
CONFIDENTIAL, PROPRIETARY INFORMATION THAT IS
INVENTUS POWER PROPERTY. DO NOT DISCLOSE TO OR
DUPLICATE FOR OTHERS EXCEPT AS AUTHORIZED BY
INVENTUS POWER.
4/29/2022
DIMENSIONS ARE IN
TOLERANCES:
Description
INTERPRET GEOMETRIC TOLERANCING
PER: ASME Y14.5M-2018
THIS DOCUMENT MAY CONTAIN U.S. EXPORT CONTROLLED TECHNICAL DATA AND/OR TECHNOLOGY. U.S. GOVERNMENT APPROVAL
MAY BE REQUIRED PRIOR TO DISCLOSURE TO NON-U.S. PERSONS, (WHEREVER LOCATED); OR AS AUTHORIZED BY U.S. LAW AND
REGULATIONS.
sbm-01-rENDER-DRAWING
eli.goldin - 11/11/2022 12:27:13 PM
DECIMALS
ANGLE
EXPORT CONTROL
ROHS CERTIFICATION
REQUIRED WITH
DELIVERY
REACH
CERTIFICATION
REQUIRED WITH
DELIVERY
MATERIALS USED IN
THIS PART MUST BE
CONFLICT FREE
MINERALS
PROJECTION
DESCRIPTION:
mm
CROSS REFERENCE PART NO.
X X
N/A
Other manuals for SBM-01
1
Table of contents
Other Inventus Power Monitor manuals