INVT ICA100-02 Series User manual


ICA100-02 IoT Data Transmission Terminal Change history
Change history
No.
Change description
Version
Release date
1
First release.
V1.0
December 2021
2
3
4
5
6
7
8
9
10


ICA100-02 IoT Data Transmission Terminal Contents
i
Contents
Contents....................................................................................................................................i
1 Product overview..................................................................................................................1
1.1 Product features...........................................................................................................1
1.2 Product specifications ..................................................................................................2
1.3 Model instruction ..........................................................................................................2
1.4 Port instruction .............................................................................................................3
1.5 Indicator instruction......................................................................................................4
2 Installation.............................................................................................................................5
2.1 Overview ......................................................................................................................5
2.2 Unpacking inspection...................................................................................................5
2.3 Outline Dimensions......................................................................................................5
3 Operation guide....................................................................................................................6
3.1 Operation description...................................................................................................6
3.2 IoT policy configuration ................................................................................................7
3.3 FAQs ............................................................................................................................9

ICA100-02 IoT Data Transmission Terminal Product overview
-1-
1 Product overview
INVT ICA100-02 series IoT data transmission terminal is a kind of WIFI wireless data terminal
for Internet of Things (IoT). Aiming at the need for RS485 communication, the data
transmission terminal collects the device data of the RS485 interface through the ModbusTCP
protocol, and provides users with wireless long-distance data transmission function through
the public operator network. Its stability and reliability meet the requirements of industrial
application scenarios.
The product adopts a high-performance industrial-grade 32-bit communication processor and
industrial-grade wireless module, with an embedded real-time operating system as the
software support platform, and also provides RS485 interfaces, thus enabling PLC and other
devices to upload the data to the cloud.
1.1 Product features
Standard set-up for easy operation
Provides standard RS485 interfaces for direct connection to serial devices for data
acquisition.
Provides easy-to-use configuration tools.
With intelligent data terminal, able to enter the data transmission status after the terminal
is connected to the router WIFI.
Adopts standard rail installation.
With powerful center management software, facilitating device management. (Optional)
Powerful functions
Supports cloud-platform management on devices, facilitating remote management and
device intelligence.
Embedded with standard TCP/IP protocol stacks, supporting multiple transmission
protocols.
Able to directly connect to serial devices, supporting up to 40 groups of Modbus register
collection for terminal devices.
Supports software watchdog to guarantee system stability.

ICA100-02 IoT Data Transmission Terminal Product overview
-2-
1.2 Product specifications
Function
Description
Function mode
AP Server: Create a hotspot. Wireless configuration is available in this
mode.
STA Client: Connect remote server through router to upload the collected
data to the cloud.
Supported
interfaces
1 RS485 interface
1 factory reset button
Indicator
Power indicator, network status indicator, running status indicator
Communication
protocol
MoudbusRTU protocol
IoT MQTT communication protocol
Wireless
parameters
WIFI standard: 2.4Ghz, IEEE802.11b/g/n
Data transmission rate: Up to 150Mbps
Transmission distance: not less than 30 meters under barrier-free
conditions
Power supply
DC10–25V
Temperature
range
-25–+60ºC
Shell
With shell, ingress protection (IP) rating IP20
Installation
method
Rail-mounted
1.3 Model instruction
Model name illustration of INVT ICA series data transmission terminal:
ICA***–***–**
①② ③ ④⑤ ⑥ ⑦ ⑧⑨
Symbol
Description
Contents
①
Product series
abbreviation
ICA: Internet CommunicationAdapter
②
Wireless
communication
mode
0: Do not support wireless communication
1: WIFI
2: GPRS
3: 3G
4: 4G
5: 5G

ICA100-02 IoT Data Transmission Terminal Product overview
-3-
Symbol
Description
Contents
③
Wire communication
mode
0: Do not support wire communication
1: Ethernet
④
Local data collection
mode
0: RS485
1: Ethernet
2: CAN
3: RS485+Ethernet
4: RS485+CAN
5: Ethernet+CAN
6: RS485+Ethernet+CAN
7: RS485+Ethernet+VPN
⑤
SIM card type
0: Plug-in card (Standard, default)
1: Embedded SIM card
This bit is omitted for WIFI products.
⑥
IP rating
0: IP00 (without shell)
1: IP20 (wall-mounted shell)
2: IP20 (rail-mounted shell)
6: IP65 (direct-insert shell)
⑦
Special function
G: with GPS
U: with USB flash disk
A: supports audio
V: supports video
This bit is omitted for standard configuration since it
does not carry additional functions.
⑧
Voltage type
5: 4.5–6V.
The voltage for standard configuration is 10V–30V,
so this bit is omitted for standard configuration.
⑨
International version
CN: China version
EU: Europe version
LA: Latin America version
This bit is omitted for WIFI products.
1.4 Port instruction
Port identifier
Port description
24V
Power supply +
GND
Power supply -
485+
485A

ICA100-02 IoT Data Transmission Terminal Product overview
-4-
Port identifier
Port description
485-
485B
WIFI
WIFI antenna
RESET
Press and hold the button for 6s to restore to the default
settings
1.5 Indicator instruction
Indicator identifier
Description
NET
Network indicator
ON: AP mode
Flash (ON: 1s and OFF: 1s): Networking is not configured in
STA mode
Flash (ON: 100ms and OFF: 100ms): Connecting to the
network
Flash (ON: 100ms and OFF: 3s): Network is connected
RUN
Running indicator
Flash (ON: 1s; OFF: 1s): System runs properly
ON or OFF: System exceptions
POWER
Power supply indicator

ICA100-02 IoT Data Transmission Terminal Installation
-5-
2 Installation
2.1 Overview
ICA series IoT data transmission terminal must be installed properly to achieve the designed
function. Generally, the installation must be done under the guidance of our certified and
qualified engineers.
Note: Do not conduct installation with the power on.
2.2 Unpacking inspection
Before unpacking, check whether the package is in good condition and its product information
is the same as on the order. The packing materials should be well maintained during
inspection for future transshipment. If any question, please contact the supplier.
Table 2-1 Product deliverables
Deliverables
Qty
Remark
WIFI data transmission terminal
1
WIFI antenna
1
PIN terminal
1
4PIN terminal
2.3 Outline Dimensions
The outline dimension of the IP20 model is as follows (unit: mm)
122.8
55.7
114
32
51.7

ICA100-02 IoT Data Transmission Terminal Operation guide
-6-
3 Operation guide
3.1 Operation description
Equipment required: Networked computer, WIFI data transmission terminal.
3.1.1 WIFI configuration procedure
1. Connect the power cable and WIFI antenna based on the port description and power on
the WIFI data transmission terminal. If the NET yellow indicator is ON in AP mode, a
hotspot has been created on the WIFI module.
2. Download the iWoStudio software from the official website and install it on your laptop.
3. In the bottom right corner of your desktop, click the network button to select the WIFI
hotspot corresponding to the WIFI module in the wireless network list.
Note: The name of the WIFI hotspot is the serial number on the barcode, and the
password is "00 + the secret key on the barcode".
4. Start the iWoStudio software and go to the WIFI card configuration page. Select or enter
the router WIFI name, enter the password, and click Config.
5. WIFI data transmission terminal is switched to the STA mode after the configuration. The
network connection status can be viewed by the NET indicator.
Note: To make changes to the configuration, press and hold the RESET button for more
than 6s to restore to the default settings and configure again.
3.1.2 IoT monitoring procedure
1. Record the device ID and 6-digit key from the label and add them to the IoT monitoring
system (website: https://iot.invt.com/login).
2. Connect the power cable, RS485 communication cable, and WIFI antenna based on the
port description.
3. Configure the WIFI module, power on and start the WIFI data transmission terminal.

ICA100-02 IoT Data Transmission Terminal Operation guide
-7-
4. If the yellow NET indicator is ON for 100ms and OFF for 3s, the WIFI module is network
ready and the data transmission starts.
5. Go to real-time monitoring interface to review relevant information in IoT monitoring
system.
3.2 IoT policy configuration
The product is equipped with powerful and easily-operated parameter configuration tool
(Assist) which carried user-friendly interface and supports one-key configuration and policy file
upgrades.
1. Create a new text file with suffix set as viewable in attribute, and write the policy
configuration command into the file one by one per below format:

ICA100-02 IoT Data Transmission Terminal Operation guide
-8-
The first line is commands for setting up APN network, user name, and password.
The second line is commands for Modbus address clearing.
The third line is commands for setting up Modbus address of the device; M (device
quantity 1), W (5s waiting time), R (rewrite times), ADDR (address 1), B (baud rate), D
(data bit), S (stop bit), P (parity bit NONE:0,ODD:1,EVEN:2), T (J: construction
machinery), G: (number of register groups), group 1 (number of registers: start address of
register: data-rewrite interval), group 2 (number of registers: start address of register:
data-rewrite interval).
The forth line is commands for network port IP setting; MSIP (device IP), PORT (port),
LOCALIP (local IP).
The fifth line is commands for turning off the commissioning information.
The sixth line is commands for policy name which is the same as the file name.
The seventh line is the end line command.
Change the suffix of the file name to tac and click Save. Then, re-open the file path, and
click Config to complete. In the advanced function, click the corresponding policy inquiry
button and check in the feedback message box whether the policy is the same with the
setting.
2. The Advance function allows you to view all configured policies and commissioning
information, set APN, and reset and upgrade the firmware version.
Note: Policy file creation and burning can also be done in iWoStudio. See the iWoStudio
help manual for details.

ICA100-02 IoT Data Transmission Terminal Operation guide
-9-
3.3 FAQs
1. After powering on, the power indicator does not flash or light up.
Answer: Check if input voltage VIN and GND are in consistent with the silkprint on the casing.
2. After power on for three minutes, the network status indicator indicates that the
network is connected, but no data is displayed on the web page.
Answer:
1) Check that the router network is available;
2) Move the antenna of the IoT transmission terminal to a place with good signal.
3) Contact the factory to check whether the device ID is registered.
3. Data uploading doesn't match the web page display.
Answer:
1) Re-power on and upload all data again.
2) Check whether the order and device type is matching, if not, please contact the
manufacturer.
4. The indicator flashes normally but the web system displays no data.
Answer: Check the communication cable between the Modbus terminal device and IoT
transmission terminal is well connected.
5. The web system only displays data content but can't send command.
Answer: Check that the signal enabling switch of the Modbus terminal device is turned on.

202112 (V1.0)
66001 - 0 0 928