InWin RJ-460-08 User manual

RJ-460-08 User Guide PAGE 1 OF 35
RJ-460-08 USER GUIDE
Version 1.1
2022/3/15

RJ-460-08 User Guide PAGE 2 OF 35
1 Table of Contents
1 Table of Contents .................................................................................................................................. 2
2 Introduction .......................................................................................................................................... 3
2.1 Overview ....................................................................................................................................... 3
2.2 Key Features .................................................................................................................................. 4
2.3 SAS Topology ................................................................................................................................. 5
3 System Interface ................................................................................................................................... 8
3.1 Overview ....................................................................................................................................... 8
3.2 Front Panel .................................................................................................................................... 8
3.2.1 LED ........................................................................................................................................ 8
3.2.2 Button Control ...................................................................................................................... 9
3.2.3 Advance Button Control ...................................................................................................... 10
3.2.4 Buzzer .................................................................................................................................. 10
3.3 Rear Panel ................................................................................................................................... 10
3.4 Bridge Expander Module ............................................................................................................ 11
3.5 Edge Expander Module ............................................................................................................... 15
4 Command Line Interface (CLI) ............................................................................................................. 16
4.1 help ............................................................................................................................................. 16
4.2 rev ............................................................................................................................................... 17
4.3 showmfg ...................................................................................................................................... 18
4.4 sasaddr ........................................................................................................................................ 18
4.5 date ............................................................................................................................................. 19
4.6 showlogs ..................................................................................................................................... 19
4.7 clearlogs ...................................................................................................................................... 20
4.8 showpost ..................................................................................................................................... 20
4.9 sesinfo ......................................................................................................................................... 21
4.10 sensor .......................................................................................................................................... 22
4.11 hdd .............................................................................................................................................. 23
4.12 console ........................................................................................................................................ 24
4.13 bpsys ........................................................................................................................................... 24
4.14 ipconfig ........................................................................................................................................ 30
4.15 fdl ................................................................................................................................................ 33
4.16 tftpfdl .......................................................................................................................................... 34

RJ-460-08 User Guide PAGE 3 OF 35
2 Introduction
2.1 Overview
In-Win’s RJ-460-08 JBOD System is a high performance, reliable storage system with sensors to
monitor system health and high-density 4U 60-bay enclosure. We provide state-of-the-art
management functionality for users to monitor and manage JBOD systems efficiently and
flexibly. Users can manage JBOD systems through serial port and/or Ethernet according to the
system configuration on the system.
FIGURE 1 RJ-460-08 INTERNAL BACKPLANES
Figure 1 depicts the internal boards system. The backplanes, front panel and power suppliers
are shared by primary (BRIDGE-P, EDGE1-P and EDGE2-P) and secondary domain (BRIDGE-S,
EDGE1-S and EDGE2-S). The secondary domain is optional for redundant applications.

RJ-460-08 User Guide PAGE 4 OF 35
2.2 Key Features
Reliable High Data Rate Support (up to 12Gbps)
o SAS3 12Gbps support and SATA3 6Gbps support to provide a reliable high-
performance data rate.
Dual SAS3 Domain Support
o System can accommodate dual domain expanders to support data redundancy
capability.
Power Redundancy
o System can accommodate 2 sets of power modules as redundancy. Either power
module could work independently while the peer is out of order or not selected.
Hot-swappable Modules
o The PSUs are hot-swappable. System can keep operating during PSU
replacement.
o The fan modules are hot-swappable. System can keep operating during fan
module replacement.
o The HDDs are hot-swappable. No need to shut down the system for HDD
installation and/or replacement when needed.
TCP/IP Network Support
o Support ethernet 10/100/1000Mb TELNET/TFTP/HTTP network. User can use
ethernet port to enter console and control the system.
Faulty System Alarm
o The Faulty System red LED indicator on the front panel illuminates along with a
beeping sound while there is faulty part(s) in the system. The buzzing alarm can
be muted by pressing the mute button on the front panel.
Smart Fan Control
o The fan modules possess a smart control feature set by the providing seven
levels of speed RPM according to the detected system temperature.
Zoning
o This system support feature dividing disk drives into two or three different
groups depending on the system preference. Each group can own users-
configurable number of HDDs independently. This feature enables single JBOD to
serve multiple hosts.
Cascading
o There are cascading ports for cascading another JBOD system to expand disk
space when more space is required

RJ-460-08 User Guide PAGE 5 OF 35
2.3 SAS Topology
Tree topology reduces the number of cascade levels (or hops), avoiding or reducing the unfair
arbitration that can affect the far-end devices in cascade topology. RJ-460-08 uses tree
topology to reduce the number of cascade levels, avoiding or reducing the unfair arbitration.
There are 3 expanders to extend the number of devices in a SAS domain. Bridge expander is the
root and two edge expanders cascaded. Figure 2 depicts the topology.
FIGURE 2 RJ-460-08 SAS TOPOLOGY
RJ-460-08 can support path redundancy applications. It constructs path-redundant topologies
using multi-ported devices as the Figure 3 illustrates. This topology is suitable for high-
availability systems since it can fail over to a different path when one path fails.

RJ-460-08 User Guide PAGE 6 OF 35
FIGURE 3 REDUNDANT SAS SYSTEM
RJ-460-08 system is a 60-bays redundant JBOD system. There is a SAS-3 path-redundancy
topology and is suitable for high availability system. Each SAS-3 domain has three expanders.
One is called bridge expander and the others are called edge expander. HDD bay 1~24 are
controlled by edge1, 25~48 are controlled by egde2 and 49~60 are controlled by bridge. Bridge
expander connects both edges (downstream) and RAID or HBA card (upstream from host side).
Figure 4 and 5 show examples of the RAID application view with 7 HDDs case. RJ460BridgeP
expander has slot56, slot57 SATA SSD hard disks installed. RJ460Edge2P expander has slot32
SAS, slot42 SATA SSD hard disks installed. RJ460Edge1P expander has slot3 SATA SSD, slot17
SAS, slot20 SATA SSD hard disks installed.

RJ-460-08 User Guide PAGE 7 OF 35
FIGURE 4 MEGARAID EXAMPLE
FIGURE 5 LSI STORAGE AUTHORITY EXAMPLE

RJ-460-08 User Guide PAGE 8 OF 35
3 System Interface
3.1 Overview
The RJ-460-08 system components includes:
Front panel with power, ID, and mute buttons and HDD status, system status and ID
LED.
Rear side with fan, bridge expander and CRPS modules
Inside of the chassis with edge expander modules, HDD trays and other backplanes.
3.2 Front Panel
Figure 6 shows the buttons, LEDs detail on front panel.
FIGURE 6 FRONT PANEL DETAIL
3.2.1 LED
The system is equipped with LEDs to provide status information for indicating component
current state.

RJ-460-08 User Guide PAGE 9 OF 35
Power LED (blue color)
Power is applied to the system(PSU). LED is illuminated when system is in operating.
Bay LED (dual color)
Indicates hard disk current state. There are dual color LED that blue is used for
operational and red is used for warning, error or failure.
o Blue LED steady ON – hard disk is installed and powered
o Blue LED in 4 Hz blinking – hard disk is accessed or in activity
o Red LED steady ON – hard disk is failed
o Red LED in 0.5 Hz blinking – hard disk is identified (LOCATE)
o Red LED in 1 Hz blinking – hard disk is in RAID rebuild state
Status LED (red color)
System current status
o Steady ON – System overheats
o 1 Hz blinking – System fans in error condition
ID LED (green color)
Push button and turn on to identify the enclosure
3.2.2 Button Control
There are three push-buttons on front panel and two push-buttons on rear side (on bridge
expander module).
Power button
The button is for applying or removing power from the power supply to the system
o Turn on – Press and hold for more than 3 seconds to power on system
o Turn off – Press and hold for more than 3 seconds to shutdown system
ID button
Press the button to toggle the ID LED ON and OFF
Mute button
Press the button to toggle the buzzer beeping or silence

RJ-460-08 User Guide PAGE 10 OF 35
3.2.3 Advance Button Control
Feature
Description
Auto Power-ON
Press
ID +
P
ower
buttons
simultaneously
to toggle th
is
feature. Power LED
blinks when this feature is engaged.
Cooling Mode
Press
and hole
ID
button
for
more than
5
seconds to change mode
in
turns.
There are three fan cooling modes to setup - quiet, normal, aggressive.
Default is normal mode. ID LED blinks when cooling mode is engaged.
Mute Mode
Press
and hold
Mute
button
for
more than
5
seconds to toggle mute
feature. Status LED blinks when feature engaged.
3.2.4 Buzzer
The buzzer is to notify system warning states
System Status Description
Fan Error
0.2
5
s beep and 1.
75
s silence repeatedly. (slow beeps)
Thermal Error 0.25s beep, 0.25 silence, 0.25 beep and 1.25s silence
repeatedly. (fast beeps)
Fan & Thermal Error
Alter
‘
Fan Error
’
and
‘
Thermal Error
’
repeatedly
PSU Error continuous beep
3.3 Rear Panel
FIGURE 7 BACKSIDE DETAIL

RJ-460-08 User Guide PAGE 11 OF 35
Fan modules, bridge expanders and PSU modules can be plug-in/out on the backside (rear-
side). Figure 7 depicts the location of the components.
3.4 Bridge Expander Module
FIGURE 8 BRIDGE EXPANDER MODULE
Bridge expander module (Figure 8) is the main component that controls and manages the RJ-
460-08 JBOD system. Users can use ethernet or RS-232 console cable to connect to the bridge
module using telnet or some console applications to command it by CLI.
Host port (SFF-8644)
External uplink port
RAID or HBA card connect to the bridge module
There are 4 ports (Host1, Host2, Host3 and Host4) for host connection
Expansion port (SFF-8644)
External downlink port to cascade another expander

RJ-460-08 User Guide PAGE 12 OF 35
Status LED
Works like front panel status LED
Indicates the system current state
o Steady ON – the system overheats
o 1 Hz blinking – the system fans in error condition
Port LED
There are Host1, Host2, Host3, Host4 and Expansion port LEDs
Illuminated LED Indicates host port connection (from RAID or HBA) or expansion
expander is physically connected
ID LED
Works synchronously with front panel ID LED
Illuminate to identify the chassis
ID button
Works synchronously with front panel ID button
Press to toggle the ID LED ON/OFF
UART Console
The RS-232 port on the Bridge Expander module provides a serial connection for users
to manage the JBOD system with terminal application such as Tera Term, Hyper
Term…etc. To manage the JBOD system through the serial port, configure the terminal
console as per the settings below to connect it.
Parameter
Value
Baud Rate 115200
Data
8 bit
Parity None
Stop Bit
1 bit
Flow Control None
Ethernet
Support 10M/100M/1G bps ethernet PHY
Support TCP/IP protocol
Support Telnet CLI
Support Webpages (http). IP address could be check from CLI then view the webpages
for system information on a web browser. Figure 9-12 are the examples of the web
pages.

RJ-460-08 User Guide PAGE 13 OF 35
FIGURE 9 VERSION PAGE
FIGURE 10 SYSTEM PAGE

RJ-460-08 User Guide PAGE 14 OF 35
FIGURE 11 NETWORK PAGE
FIGURE 12 HARD DISK PAGE

RJ-460-08 User Guide PAGE 15 OF 35
3.5 Edge Expander Module
FIGURE 13 EDGE EXPANDER MODULE
This edge expanders are connected to the bridge expander module by internal SFF-8643 cables.
they are controlled by bridge expander. User may manage it through bridge CLI interface
(ethernet or RS-232).
Host port (SFF-8643)
Internal uplink port
There are 2 ports (Host1 and Host2) connecting to middle plane. Host1 port must
connect to middle plane CN6 and Host2 must connect to middle plane CN7.
Expansion port (SFF-8643)
Not applicable

RJ-460-08 User Guide PAGE 16 OF 35
4 Command Line Interface (CLI)
The RJ-460-08 system provide flexible and useful commands to monitor and manage hard disk,
expanders and backplane system. Users can use telnet or console applications to manage the
system with CLI commands.
4.1 help
List all command list and the usage
Syntax
help [Command]
- X means a mandatory argument described as x
- [X] means an optional argument
- <X> means replace argument with value
- X(D) means a decimal value
- X(H) means a hexadecimal value
- X(*) means special formatting is specified
- X(s) means a decimal value in seconds
- X(ms) means a decimal value in milliseconds
- opt1|opt2|opt3 means literally specify "opt1","opt2", or "opt3"
- X1 X2 ... means a variable number of arguments
Example
Bridge >help
================================================================================
Description Command
================================================================================
Show Sensors sensor
Remote Command 2 edge2
Remote Command 1 edge1
Remote Command 0 bridge
…
Bridge >help fdl
================================================================================
Description Command
================================================================================
File download fdl <BufferID(H)> <Offset(H)> <Erase(*)>
- Erase is replaced with "Y" or "N"

RJ-460-08 User Guide PAGE 17 OF 35
================================================================================
4.2 rev
Show vendor ID, product ID, active firmware and firmware version information
Syntax
rev
Example
Bridge >rev
================================================================================
Hardware Revision Information:-
================================================================================
Vendor ID :IN-WIN
Product ID :RJ-460 Bridge(P)
Product Revision Level :Minor = 0x01, Unit = 0x02
Component Type :Cub
Component ID :0x0238 (Bond Option :48)
Component Revision Level :1 (B0)
================================================================================
Firmware Revision Information:-
================================================================================
Active Firmware: Firmware Copy 2
Boot Image:
Revision: 2.1.0.0
Platform Name: IN-WIN Cub Expander System
Version Name: SAS35xFW-02.01.00.00 07/17/20
Firmware Family: 0 OemFamily: 0
Fast Boot: Yes Image Address: 0x10000000
Firmware Copy 1:
Revision: 2.1.2.0
Platform Name: IN-WIN Cub Expander System
Version Name: SAS35xFW-02.01.02.00 08/04/21
Firmware Family: 0 OemFamily: 0
Fast Boot: Yes Image Address: 0x10180000
Firmware Copy 2:
Revision: 2.1.2.0
Platform Name: IN-WIN Cub Expander System
Version Name: SAS35xFW-02.01.02.00 08/04/21
Firmware Family: 0 OemFamily: 0
Fast Boot: Yes Image Address: 0x10300000
================================================================================
SDK Revision:-
================================================================================

RJ-460-08 User Guide PAGE 18 OF 35
HAL Revision: 0.16.0.0
SES Revision: 0.16.0.0
SCE Revision: 0.16.0.0
Spico Fw Revision: 0x8a69_014f
CSWLib Revision: 0.0.17.0
================================================================================
Current Toolchain Revision:-
================================================================================
ARM RVDS v.410713
4.3 showmfg
Show manufacture configuration version information
Syntax
showmfg
Example
Bridge >showmfg
================================================================================
Manufacturing Image Version Information:-
================================================================================
Product ID : 3
Platform ID: 3
Associated Firmware Revision: 0:11:0:0
Mfg Revision: 2:1:1:0
Product Name: RJ-460 Bridge(P)
Platform Name: Expander Cub x48
Mfg Image Creation time stamp: 8/18/21 7:27 (mm/dd/yy hr:min)
4.4 sasaddr
display expander’s SAS address
Syntax
sasaddr
Example
Bridge >sasaddr
Expander SAS Addresses -
SxP Port 0 SAS Address: 0x500605B0000272BD
SxP Port 1 SAS Address: 0x500605B0000272BF
SxP Port 2 SAS Address: 0x0000000000000000

RJ-460-08 User Guide PAGE 19 OF 35
4.5 date
Show or set current date time. There are no RTC in system. System always starts up at
incorrect date. System log will record event with datetime. User can set datetime and
broadcast the new value to other expanders by ‘date send’
Syntax
date [ set <newdate(*)> | send [<SasAddrHi(H)> <SasAddrLow(H)>] |
recv [<SasAddrHi(H)> <SasAddrLow(H)>] ]
- no arguments, output local expander date/time and uptime
- 'set <newdate(*)>' Set local expander date/time using format for <newdate> of
YYYYMMDDHHMMSS
- 'send [sas_addr]' If sas_addr set then set the remote expander's clock using the
local expander's current clock value. If sas_addr not specified then set clock
for all expanders in the domain.
- 'recv [sas_addr]' If sas_addr set then fetch the remote expander's current clock
and output the result. If sas_addr not specified then get and output the current
clock for all expanders in the domain.
Example
Bridge >date
Wed Jan 1 00:00:32 2020
Current expander uptime is 0 days, 0 hours, 16 minutes, 26 seconds
Bridge >date set 20210910103000
Expander date/time set to Fri Sep 10 10:30:00 2021
Bridge >date send
Result sending SET TIMESTAMP to 5fae190a0000167d: SUCCESS
Bridge >edge1 date
>>>edge1:
Fri Sep 10 10:30:26 2021
Current expander uptime is 0 days, 0 hours, 16 minutes, 59 seconds
4.6 showlogs
Show the current system logs
Syntax
showlogs [hex|detail|default]

RJ-460-08 User Guide PAGE 20 OF 35
Example
Bridge >sho
wlogs
<Jul 14 2021 02:59:35.328>:SES Log:SES cfg pg (id EE04) is unreadable
<Jul 14 2021 02:59:35.332>:PLATFORM:Firmware initialization started
<Jul 14 2021 02:59:36.668>:EXP:FW COPY 1 REGION: FW image missing
<Jul 14 2021 02:59:36.670>:EXP:FW COPY 2 REGION: FW image missing
<Jul 14 2021 02:59:36.670>:CONFIG:Expander MFG image is not valid
…
4.7 clearlogs
Clear the system logs
Syntax
clearlogs
Example
Bridge >clearlogs
Bridge >showlogs
Bridge >
4.8 showpost
Show POST (Power-On-Self-Test) status of expander
Syntax
showpost
Example
Bridge >showpost
POST status of expander on-chip devices
================================================================================
On-Chip Device POST Status
================================================================================
Smart Serial :PASS
Watchdog Timer :PASS
Timer 1 :PASS
Table of contents
Other InWin Storage manuals
Popular Storage manuals by other brands

LaCie
LaCie SRD0FV0 user manual

Lindy
Lindy Gigabit soho nas box Quick installation guide

Seagate
Seagate Barracuda 7200.8 ST3400832A product manual

XBOX
XBOX Wasabi 360 Ultra installation guide

Sony
Sony MSAC-US40 - MemoryStick Flash Memory Card USB 2.0... operating instructions

Habey
Habey BIS-6621 Quick setup guide