manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IOLINK
  6. •
  7. Control Unit
  8. •
  9. IOLINK S4A Series User manual

IOLINK S4A Series User manual

This manual suits for next models

3

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

S4A Series 4Points DC input/AC Load SSR Board
User’s Guide
Thank you for purchasing product of SAMWON ACT.
Please check model of product that you purchase first, and read this manual prior to use it.
●Caution for Safety
Caution
Case that results in serious damage in human body or equipment, and fire if user handles this equipment wrongly
Warning
Case that results in slight damage in human body or equipment, and fire if user handles this equipment wrongly
Caution
1. Do Not use other voltage except appointed voltage. It may be the cause of fire or damage of equipment.
2. Use it within nominal voltage and current which are marked on load. It may be the cause of fire or damage of equipment.
3. Check COMMON polarity of using controller (PLC, etc) first, and then select proper product.
It may be the cause of fire or damage of this equipment and user's.
4. Make controller and connection cable between relay boards after checking internal wiring of relay board and
PIN(terminal or socket) array of controller if you want to make it for yourself.
It may be the cause of fire, and malfunction or damage of this equipment and user's.
Warning
1. Plug or unplug power line and/or connector for signal after making sure to shut off power so as that
it is prevented to be damaged or malfunctioned.
2. Read this user's guide which is attached to product, and check product's performance, specification,
operation pattern, signal, and how to handle prior to use. Keep user's guide please.
3. When wiring the terminal block, please tighten it with the specified torque using the appropriate tool.
If it is outside of this range torque, it may cause malfunction due to breakage or looseness of tightening surface terminal.
4. Use removal key which is supplemented for replacement.
Using other tools may be the cause of damage of relay or relay socket.
77.4
65(Hole of fixing)
36(Hole of fixing)
43.6
Channel lever
38.9
Relay replacement tool
8.5
M3.5 Bolt
Operation indicator
432
1
8
IN
OUT
76
5
15
+
4
16
OUTPUT
12
8
INPUT
-
+
1
+
2
+
3
13
14
11 10
7 6
9
5
- - -
●Model Selection
Model Installation
Relay
IO
Point(s)
Input
Rated voltage
Common Interface Dimensions
(W*D㎜)
Mounting
method
Input Output Input Output
S4A-5V-2Z PANASONIC
AQG22105
4Point
(4a * 4)
5V DC Individual
Power
(4P Short
bar built)
Individual
Com.
(4P Short
bar built)
Screw Terminal
8.5mm Pitch 43.6 *77.4
Screw
mounting
DIN Rail
(Channel)
S4A-12V-2Z PANASONIC
AQG22112 12V DC
S4A-24V-2Z PANASONIC
AQG22124 24V DC
NO.202001-OM-ENG-S4A(rev.01)
Item
AQG22124
AQG22105 AQG22112 AQG22124
Input
Input voltage 4 to 6 V DC 9.6 to 14.4 V
19.2~28.8V DC
Input impedance
Approx. 0.3kΩApprox. 0.8kΩApprox. 1.6kΩ
Drop-out voltage. min. 1V
Reverse voltage 3V
Output
Max. load current 2A AC (Max.25℃)
Load voltage 75 to 264V AC
Frequency 45 to 65 Hz
Non-repetitive surge current
30A (In one cycle at 60Hz)
Max.“OFF-state leakge current
1.5mA (at 60Hz / 200V AC)
Max.“ON-state leakge drop
1.6V (at Max. carrying current)
Min. load current 20mA
Characteristics
Operate time, max. 1/2 cycle of voltage sign wave+1ms
Release time, max. 1/2 cycle of voltage sign wave+1ms
Breakdown voltage 3000V rms/1min (between input and output)
Insulation resistance, min 10Ω(between input and output)
Country of origin JAPAN
●AQG22124 Specification (Ambient temperature 25℃)
●Dimension ●Diagram
•4Pole Short bar (2ea)
●Material/Specification
●Applicable crimp terminal
●Accessories
Case Modified PPO
Protective cover Polycarbonate
P.C.B Epoxy 1.6t / 2oz
Applicable wire AWG22~16 (MAX 1.5㎟)
Terminal Screw M3.5 X 10L
Screw torque
7~8kgf•cm
(0.68~0.78 N•m)
Ambient
temperature
-10℃~ +50℃
(No condensation)
Major products
■Relay terminal 1, 2, 4, 6, 8, 16, 32point
■Interface terminal 20, 24, 26, 34, 40, 50, 57, 40 x 2pole
■PLC I/O Connecting cables MITSUBISHI, LSIS, CIMON, OMRON, FUJI, YOKOGAWA, HITACHI, SIEMENS, AB, etc.
■Servo Connecting cables Encoder cable, Power cable, Motion cable / MITSUBISHI, YASKAWA, OMRON, PANASONIC, , LSIS, SAMSUNG, etc.
■Wiring harness / Special cable assembly
※The above specifications are subject to change without notice.
※Please contact HQ or branch office where you purchased product for A/S of this product or technique.
■HQ : 47035, 28, Daedong-ro, Sasang-gu, Busan, Korea
TEL : (051)320-7777 FAX : (051)312-2233
■SEOUL Office: 501, Iljik-dong, Gwangmyeong-si, Gyeonggi-do
TEL : (02)837-2230 FAX : (02)837-2226