IOtech DaqBoard /1000 Series User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Measurement Computing / IOtech DaqBoard/2000 at our website: Click HERE

© 1999 through 2005 by IOtech, Inc. 879194 Printed in the United States of America
DaqBoard/1000 and /2000 Series User’s Manual
For PCI-bus & Compact PCI-bus Data Acquisition Boards
IOtech, Inc.
25971 Cannon Road
Cleveland, OH 44146-1833
Phone: (440) 439-4091
Fax: (440) 439-4093
Internet: www.iotech.com
DaqBoard/1000 & /2000 Series
User’s Manual
For PCI-bus &Compact PCI-bus
Data Acquisition Boards
p/n 1033-0901 Rev. 8.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ii
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Warranty Information
Your IOtech warranty is as stated on the product warranty card. You may contact IOtech by phone,
fax machine, or e-mail in regard to warranty-related issues.
Limitation of Liability
IOtech, Inc. cannot be held liable for any damages resulting from the use or misuse of this product.
Copyright, Trademark, and Licensing Notice
All IOtech documentation, software, and hardware are copyright with all rights reserved. No part of this product may be
copied, reproduced or transmitted by any mechanical, photographic, electronic, or other method without IOtech’s prior
written consent. IOtech product names are trademarked; other product names, as applicable, are trademarks of their
respective holders. All supplied IOtech software (including miscellaneous support files, drivers, and sample programs)
may only be used on one installation. You may make archival backup copies.
CE Notice
Many IOtech products carry the CE marker indicating they comply with the safety and emissions standards of the
European Community. As applicable, we ship these products with a Declaration of Conformity stating which
specifications and operating conditions apply.
Warnings, Cautions, Notes, and Tips
Refer all service to qualified personnel. This caution symbol warns of possible personal injury or equipment damage
under noted conditions. Follow all safety standards of professional practice and the recommendations in this manual.
Using this equipment in ways other than described in this manual can present serious safety hazards or cause equipment
damage.
This warning symbol is used in this manual or on the equipment to warn of possible injury or death from electrical
shock under noted conditions.
This ESD caution symbol urges proper handling of equipment or components sensitive to damage from electrostatic
discharge. Proper handling guidelines include the use of grounded anti-static mats and wrist straps, ESD-protective
bags and cartons, and related procedures.
This symbol indicates the message is important, but is not of a Warning or Caution category. These notes can be of
great benefit to the user, and should be read.
In this manual, the book symbol always precedes the words “Reference Note.” This type of note identifies the location
of additional information that may prove helpful. References may be made to other chapters or other documentation.
Tips provide advice that may save time during a procedure, or help to clarify an issue. Tips may include additional
reference.
Specifications and Calibration
Specifications are subject to change without notice. Significant changes will be addressed in an addendum or revision to
the manual. As applicable, IOtech calibrates its hardware to published specifications. Periodic hardware calibration is
not covered under the warranty and must be performed by qualified personnel as specified in this manual. Improper
calibration procedures may void the warranty.
Quality Notice
IOtech has been an ISO 9001 registered firm since 1996. Prior to shipment, we thoroughly test our products and
review our documentation to assure the highest quality in all aspects. In a spirit of continuous improvement,
IOtech welcomes your suggestions.
DaqBoard/1000 and /2000 Series User’s Manual iii
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

iv DaqBoard/1000 and /2000 Series User’s Manual
Your order was carefully inspected prior to shipment. When you receive your system, carefully
unpack all items from the shipping carton and check for physical signs of damage that may have
occurred during shipment. Promptly report any damage to the shipping agent and your sales
representative. Retain all shipping materials in case the unit needs returned to the factory.
Using this equipment in ways other than described in this manual can cause
personal injury or equipment damage. Before setting up and using your
equipment, you should read all documentation that covers your system.
Pay special attention to Warnings and Cautions.
Note: During software installation, Adobe®PDF versions of user manuals will automatically
install onto your hard drive as a part of product support. The default location is in the
Programs group, which can be accessed from the Windows Desktop. Initial
navigation is as follows:
Start [Desktop “Start” pull-down menu]
⇒Programs
⇒IOtech DaqX Software
You can also access the PDF documents directly from the data acquisition CD by using
the <View PDFs> button located on the opening screen.
Refer to the PDF documentation for details regarding both hardware and software.
A copy of the Adobe Acrobat Reader®is included on your CD. The Reader provides
a means of reading and printing the PDF documents. Note that hardcopy versions of
the manuals can be ordered from the factory.
PDF
1033-0901
DaqBoard 1000 and 2000 Series.pdf
Contains the DaqBoard/1000 and /2000 Series hardware-related and software-related
chapters, as well as links to the .pdf files listed below. This pdf file, plus the
following constitute a complete set of documentation for the DaqBoards discussed.
Note that the Programmer’s Manual (1008-0901) and the DBK Option Cards &
Modules
(457-0905) are completely separate documents. The later does not apply to
DaqBoard/1000 Series boards.
PDF
457-0909
DaqView.pdf
Discusses how to install and use this “out-of-the-box” data acquisition program.
PDF
1086-0926
1086-0922
PostAcquisition Analysis.pdf
This pdf consists of two documents. The first discusses eZ-PostView, a post data
acquisition analysis program. The application is included free as a part of DaqTemp
product support. The second includes information regarding eZ-FrequencyView and
eZ-TimeView. These two applications have more features than does eZ-PostView and
are available for purchase. They can; however, be used freely during a 30-day trial
period.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

DaqBoard/1000 and /2000 Series User’s Manual v
PDF
457-0905
DBK Options.pdf
The DBK Option Cards and Modules Manual discusses each of the DBK products
available at the time of print. The DBK Options document does not apply to
DaqBoard/1000 Series boards.
PDF
1008-0901
Programmers Manual.pdf
The programmer’s manual pertains to developing custom programs using
Applications Program Interface (API) commands.
Programmers should check the readme.file on the install CD-ROM for the location of
program examples included on the CD.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

vi DaqBoard/1000 and /2000 Series User’s Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Manual Layout
DaqBoard/1000 and /2000 Series, Installation Guide (p/n 1033-0940)
DaqBoard/2000c Series, Installation Guide (p/n 1061-0940)
Chapter 1 – Daq Systems and Device Overviews. This chapter begins with a discussion of the “modular
concept” that is associated with Daq data acquisition systems. The chapter then goes on to provide
an overview for each DaqBoard/1000 and /2000 Series board.
Chapter 2 –Connections and Pinouts, DaqBoard/1000 Series -This chapter includes board pinouts for
the DaqBoard/1000 Series 68-pin connector. It includes screw terminal identification for TB-100,
which is an optional terminal board connector.
Chapter 3 - Connections and Pinouts, DaqBoard/2000 Series -This chapter includes board pinouts
for the DaqBoard/2000 Series boards’ 100-pin connector (P4). The chapter includes an overview of
the DBK200 Series P4 adapters that can be used to obtain DB37 type connectors (P1, P2, and P3).
Chapter 4 - CE Compliance pertains to CE standards and conditions that are relevant to DaqBoard/1000
and /2000 Series boards. A CE Kit, which can be used for DaqBoard/2000 Series boards, is also
discussed.
Chapter 5 - Calibration lists the order in which to perform calibration-related adjustments and briefly
discusses DaqCal.exe, a program that provides on-screen instruction, graphics, and prompts.
Glossary
Reference Notes:
During software installation, Adobe®PDF versions of user manuals are automatically
installed onto your hard drive as a part of product support. The default location is in the
Programs directory, which can be accessed from the Windows Desktop.
A copy of the Adobe Acrobat Reader®is included on your CD. The Reader provides
a means of reading and printing the PDF documents. Note that hardcopy versions of manuals
can be ordered from the factory.
ÜDaqView – explains the use and features of the included out-of-the-box data
acquisition software.
ÜPost Acquisition Data Analysis User’s Guide – discusses three post-acquisition data
analysis programs: eZ-PostView, eZ-TimeView, and eZ-FrequencyView.
ÜFor detailed information regarding specific DBKs, refer to the DBK Option Cards
and Modules User’s Manual, p/n 457-0905. Each DBK section includes device-
specific hardware and software information. The document includes a chapter on
power management. DaqBoard/1000 Series boards do not support DBK options.
ÜFor programming-related information refer to the separate Programmer’s Manual,
p/n 1008-0901.
DaqBoard/1000 and /2000 Series User’s Manual 959695 vii
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

viii 969594 DaqBoard/1000 and /2000 Series User’s Manual
This page is intentionally blank.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

DaqBoard/1000 and /2000 Series User’s Manual 959695 ix
Table of Contents
DaqBoard/1000 and /2000 Series, Installation Guide (p/n 1033-0940)
DaqBoard/2000c Series, Installation Guide (p/n 1061-0940)
1 – Daq Systems and Device Overviews
Daq Systems, the Modular Concept ……1-1
Theory of Operation, DaqBoard/1000 and/2000 Series Boards…… 1-3
DaqBoard/1000 ….. 1-7
DaqBoard/1005 ….. 1-9
DaqBoard/2000…… 1-11
DaqBoard/2001 …… 1-13
DaqBoard/2002 …… 1-15
DaqBoard/2003 …… 1-17
DaqBoard/2004 …… 1-19
DaqBoard/2005 …… 1-21
Using DBK Cards & Modules for Signal Conditioning ……1-23
Note: DBK options do not apply to DaqBoard/1000 Series Boards
Daq Software …… 1-23
Specifications – DaqBoard/1000 Series Boards …… 1-25
Specifications – DaqBoard/2000 Series Boards …… 1-29
2 – Connections and Pinouts, DaqBoard/1000 Series
Overview …… 2-1
TB-100 Terminal Connector Option …… 2-2
Pinouts for DaqBoard/1000 Series Boards …… 2-3
3 – Connections and Pinouts, DaqBoard/2000 Series
Overview …… 3-1
DBK200 Series, P4 Connector Options …… 3-2
Pinouts for DaqBoard/2000 Series and /2000c Series Boards …… 3-8
4 – CE-Compliance
Overview …… 4-1
CE Standards and Directives …… 4-1
Safety Conditions …… 4-2
Emissions/Immunity Conditions …… 4-2
CE Enhancements for DBKs ...... 4-3
CE Cable Kits for DaqBoard/2000 Series and /2000c Series Boards…… 4-3
5 – Calibration
Glossary
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

x 969594 DaqBoard/1000 and /2000 Series User’s Manual
This page is intentionally blank.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

DaqBoard/1000 and /2000 Series Installation
This guide tells how to complete the following steps for a successful installation.
Step 1 – Install Software …… page 2
Step 2 – Install Boards in Available PCI Bus-Slots …… page 3
Step 3 – Configure Boards ….. page 5
Step 4 – Test Hardware ….. page 6
Reference Note:
After you have completed the installation you should refer to the electronic documents that
were automatically installed onto your hard drive as a part of product support. The default
location is in the Programs group, which can be accessed from the Windows Desktop.
You should keep your DaqBoard’s serial number and your DaqView/2000 authorization code (if
applicable) with this document. Space is provided below for recording up to 4 board numbers and their
PCI bus-slot locations. The board serial number is located on the connector as indicated in the following
figure.
Serial Number Location on DaqBoard/2000 Series Connector
The location is similar for DaqBoard/1000 Series Board.
Board Type (e.g.,
1000, 1005, 2000,
2001, etc.)*
Serial Number PCI Bus-Slot Location
Board 1
Board 2
Board 3
Board 4
The host PC can support up to four Boards.
*Note: DaqBoards have device labels which read, for example, “DaqBoard/1000,” “DaqBoard/2001,” “DaqBoard/2002,”
etc. The name labels are convenient for users of more than one board type.
DaqView/2000 Authorization Code ____________________________
Customers who ordered DaqView/2000 can find their authorization code on the authorization code sheet located inside the sleeve of the install CD.
Note that earlier documents may refer to this as a “registration code” or “registration ID.”
Customers who did not order DaqView/2000 can run a 30-day free trial version, as discussed elsewhere in the User’s Manual.
Take ESD precautions (packaging, proper handling, grounded wrist strap, etc.)
Use care to avoid touching board surfaces and onboard components. Only handle boards by their
edges (or ORBs, if applicable). Ensure boards do not come into contact with foreign elements such as
oils, water, and industrial particulate.
© 1999 through 2004 by IOtech, Inc. 898195 1033-0940, rev.8.0 IG-1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Reference Notes:
(1) Each DaqBoard plugs into a PCI bus-slot. Consult your PC owner’s manual as needed.
(2) DaqBoard/2000 Series users should read about the DBK cards and modules applicable to their acquisition system.
Specific DBK information can be found in the world wide web at http://www.daqboard.com; and in the DBK Option Cards
and Modules User’s Manual (p/n 457-0905). After the install you can navigate to the DBK manual and other relevant
electronic documents from your desktop as follows: Start ⇒Programs ⇒IOtech DaqX Software ⇒DaqBoard 2000
Series Users
Note: DaqBoard/1000 Series boards do not support DBK options.
Reference Note: Adobe PDF versions of user manuals will
automatically install onto your hard drive as a part of product
support. The default location is in the Programs group, which
can be accessed from the Windows Desktop. Refer to the PDF
documentation for details regarding both hardware and
software. Note that hardcopy versions of the manuals can be
ordered from the factory.
Minimum System Requirements
PC system with Pentium®Processor
Windows Operating System
RAM, as follows:
32 Mbytes of RAM for Windows 95/98/NT
64 Mbytes of RAM for Windows Me
64 Mbytes of RAM for Windows 2000
64 Mbytes of RAM for Windows XP
Installation, A Pictorial Overview
Step 1 –Install Software
IMPORTANT: Software must be installed before installing hardware.
1. Remove previous version Daq drivers, if present. You can do this through Microsoft’s Add/Remove
Programs feature.
2. Place the Data Acquisition CD into the CD-ROM drive. Wait for PC to auto-run the CD. This may
take a few moments, depending on your PC. If the CD does not auto-run, use the Desktop’s
Start/Run/Browse feature and run the Setup.exe file.
3. After the intro-screen appears, follow the screen prompts.
Upon completing the software installation, continue with step 2, Install Boards in available
PCI Bus-slots.
IG-2 DaqBoard/1000 and /2000 Series Installation Guide 898195 1033-0940, rev 8.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Step 2 – Install Boards in available PCI Bus-slots
IMPORTANT:Software must be installed before installing hardware.
Turn off power to, and UNPLUG the host PC and externally connected equipment prior to
removing the PC’s cover and installing the DaqBoard. Electric shock or damage to equipment
can result even under low-voltage conditions.
Take ESD precautions (packaging, proper handling, grounded wrist strap, etc.)
Use care to avoid touching board surfaces and onboard components. Only handle boards by their
edges (or ORBs, if applicable). Ensure boards do not come into contact with foreign elements such
as oils, water, and industrial particulate.
IMPORTANT: Bus Mastering DMA must be Enabled.
For a DaqBoard/1000 or /2000 Series board to operate properly, Bus Mastering DMA must be
Enabled on the PCI slot [for which the board is to be installed]. Prior to installation, verify that
your computer is capable of performing Bus Mastering DMA for the applicable PCI slot. Note that
some computers have BIOS settings that enable [or disable] Bus Mastering DMA. If your
computer has this BIOS option, ensure that Bus Mastering DMA is Enabled on the appropriate
PCI slot.
Refer to your PC Owner's Manual for additional information regarding your PC and enabling
Bus Mastering DMA for PCI slots.
1. Turn off power to, and UNPLUG the host PC and externally connected equipment.
2. Remove the PC’s cover. Refer to your PC Owner’s Manual as needed.
3. Choose an available PCI bus-slot.
4. Carefully remove the DaqBoard from its anti-static protective bag. If you have not already done so,
write down the serial number of your board at this time.
5. Refer to the figure at the right. Remove the screw that
secures the blank adapter plate, which is associated with the
PCI slot you will be using. Refer to your PC Owner’s
Manual if needed.
6. Remove the blank adapter plate.
Removing a Blank Adapter Plate
1033-0940, rev 8.0 898195 DaqBoard/1000 and /2000 Series Installation Guide IG-3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

7. Refer to the figure at the right. Align the groove in the
DaqBoard’s PCI edge-connector with the ridge of the
desired PCI slot, and with the PC’s corresponding rear-
panel slot.
8. Push the board firmly into the PCI slot. The board will
snap into position.
9. Secure the board by inserting the rear-panel adapter-plate
screw.
10. Using the previous steps, install additional boards into
available PCI bus-slots, if applicable to your application.
11. Replace the computer’s cover.
12. Plug in all cords and cables that were removed in step 1.
13. Apply power to, and start up the PC.
Note: At this point some PCs may prompt you to insert an
installation disk. While this is rare, if you do receive such a
prompt simply place the install CD-ROM into the disk drive
and follow additional screen prompts.
Installing a DaqBoard/2000 Series Board
IG-4 DaqBoard/1000 and /2000 Series Installation Guide 898195 1033-0940, rev 8.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Step 3 –Configure Boards
DaqBoard/1000 and /2000 Series Boards have no jumpers or switches to set. Configuration is performed,
in its entirety, through software. Refer to the following figure and steps to complete the configuration.
The numbers in the figure correspond to the numbered steps immediately following the figure.
Accessing the DaqBoard/2000 Properties Tab
Note: Images are similar for DaqBoard/1000 Series.
1. Run the Daq Configuration control panel applet. Navigation from the desktop to the applet is as follows:
Start ⇒Settings ⇒Control Panel ⇒Daq*Configuration (double-click)
2. Double-click on the Device Inventory’s DaqBoard2K0 or DaqBoard1K0 icon, as applicable. The DaqBoard’s
Properties tab will appear. If the DaqBoard icon is not present, skip to the upcoming Using ‘Add Device’
section.
3. Enter a “Device Name” in the text box, or use the default, e.g., DaqBoard2K0. The Name is for identifying the
specific DaqBoard, but actually refers to the PCI slot.
4. Verify that the “Device Type” shows the correct board, e.g., “DaqBoard/1000, DaqBoard/2001, etc.”
Note that available device types can be viewed via the pull-down list.
5. Confirm that the DaqBoard’s text box shows a Bus #, Slot #, and Serial Number.
If this text box is empty, use its pull-down list and select the serial number that matches the one for your board.
1033-0940, rev 8.0 898195 DaqBoard/1000 and /2000 Series Installation Guide IG-5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Using “Add Device”
This method is for users who have accessed the Daq Configuration
control panel applet, but have no DaqBoard1K icon or DaqBoard2K icon
[as described on page IG-5, step 2].
(A) After accessing the Daq Configuration control panel applet, click on
the <Add Device> button (see figure, right). The Select Device Type
window will appear.
(B) Using the Device Type’s pull-down list, select the applicable board.
In the example at the right DaqBoard/2000 is selected.
(C) Click the <OK> button. The board’s Properties tab will appear.
Note that this tab will apply to all boards in the series.
At this point, complete steps 3 through 5 from page IG-5.
Using “Add Device”
Step 4 –Test Hardware
Use the following steps to test the DaqBoard board. Note that these steps are continued from those listed under the
previous section, “Configure Board.”
1. Select the “Test Hardware” tab.
2. Click the “Resource Test” button.
3. After the test is complete, click “OK.”
System capability is now tested for the DaqBoard and a list
of test results appears on screen.
Note: If you experience difficulties, please consult your user
documentation (included on your CD) before calling for
technical support. Note that the user documentation
includes a troubleshooting chapter, as well as a great
deal of information regarding specific DBK cards and
modules, which can be used with DaqBoard/2000
systems.
Test Hardware Tab
(Condensed Screen Image)
At this point we are ready to connect signals.
•For DaqBoard/2000 Series boards, signal connection is typically accomplished with the use of a
DBK200 Series option.
•For DaqBoard/1000 Series boards, connection is typically made via a terminal board, such as the
optional TB-100.
Reference Notes:
ÜDaqBoard/2000 Series users: For detailed information regarding the DBK200 Series options, refer
to the DBK Option Cards and Modules User’s Manual (p/n 457-0905).
ÜDuring software installation, Adobe®PDF versions of user manuals are automatically installed onto
your hard drive as a part of product support. The default location is in the Programs group, which
can be accessed from the Windows Desktop. A copy of the Adobe Acrobat Reader®is included on
your CD. The Reader provides a means of reading and printing the PDF documents. Note that
hardcopy versions of manuals can be ordered from the factory.
IG-6 DaqBoard/1000 and /2000 Series Installation Guide 898195 1033-0940, rev 8.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

DaqBoard/2000c Series Installation
This guide tells you how to complete the following steps for a successful installation.
Step 1 – Install Software …… page 2
Step 2 – Install Boards into Available, 5 Volt, Compact-PCI Bus-Slots …… page 2
Step 3 – Configure Boards ….. page 4
Step 4 – Test Hardware ….. page 5
Reference Note:
After you have completed the installation you should refer to the electronic documents that
were automatically installed onto your hard drive as a part of product support. The default
location is in the Programs group, which can be accessed from the Windows Desktop.
You should keep your DaqBoard/2000c Series board’s serial number and your DaqView/2000
authorization code (if applicable) with this document. Space is provided below for recording up to 4 board
numbers and their compact-PCI bus-slot location. Board serial numbers are located on the 100-pin P4
connector.
Board Type
e.g., DaqBoard/2005c
Serial Number Compact-PCI Bus-Slot Location
Board 1
Board 2
Board 3
Board 4
Compact PC support for DaqBoard/2000c Series boards varies. A system can support no more than four boards.
*Note: The DaqBoard/2000c Series boards have their board identity indicated on the latch, as indicated in
the photo on the front page of this guide. This identification is provided since the boards look very
much alike and are visually identical once installed.
DaqView/2000 Authorization Code ____________________________
Customers who ordered DaqView/2000 can find their authorization code on the authorization code sheet located inside the
sleeve of the install CD. Customers who did not order DaqView/2000 can run a 30-day free trial version, as discussed in the
user’s manual.
CAUTION
Take ESD precautions (packaging, proper handling, grounded wrist strap, etc.)
Use care to avoid touching board surfaces and onboard components. Only handle
boards by their edges (or ORBs, if applicable). Ensure boards do not come into contact
with foreign elements such as oils, water, and industrial particulate.
Reference Note:
During software installation, Adobe®PDF versions of user manuals are automatically installed
onto your hard drive as a part of product support. The default location is in the Programs
group, which can be accessed from the Windows Desktop. A copy of the Adobe Acrobat
Reader®is included on your CD. The Reader provides a means of reading and printing the
PDF documents. Note that hardcopy versions of manuals can be ordered from the factory.
Note: In regard to functionality, the DaqBoard/2000c Series boards are identical to their
DaqBoard/2000 Series counterparts.
© 2001 through 2004 by IOtech, Inc. 979294 1061-0940, rev. 4.0 IG-1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Reference Notes:
ÜEach DaqBoard/2000c Series Board plugs into a 5 volt, compact-PCI bus-slot located on the PC’s backplane. Note
that the 5 V compact-PCI bus-slot contains a blue key (see page 3). Consult your PC owner’s manual as needed.
ÜBe sure to read about the DBK cards and modules applicable to your acquisition system. Specific DBK information
can be found in on the world wide web at http://www.daqboard.com; and in your DBK Option Cards and Modules
User’s Manual (p/n 457-0905). After the install you can navigate to the DBK manual and other relevant electronic
documents from your desktop as follows:
Start ⇒Programs ⇒IOtech DaqX Software ⇒DaqBoard 2000 Series Users
Reference Note: Adobe PDF versions of user manuals will
automatically install onto your hard drive as a part of product
support. The default location is in the Programs group, which
can be accessed from the Windows Desktop. Refer to the PDF
documentation for details regarding both hardware and
software. Note that hardcopy versions of the manuals can be
ordered from the factory.
Minimum System Requirements
PC system with Pentium®Processor
Windows Operating System
RAM, as follows:
32 Mbytes of RAM for Windows 95/98/NT
64 Mbytes of RAM for Windows Me
64 Mbytes of RAM for Windows 2000
64 Mbytes of RAM for Windows XP
Step 1 –Install Software
IMPORTANT: Software must be installed before installing hardware.
1. Remove previous version Daq drivers, if present. You can do this through Microsoft’s Add/Remove
Programs feature.
2. Place the Data Acquisition CD into the CD-ROM drive. Wait for PC to auto-run the CD. This may
take a few moments, depending on your PC. If the CD does not auto-run, use the Desktop’s
Start/Run/Browse feature.
3. After the intro-screen appears, follow the screen prompts.
Upon completing the software installation, continue with step 2, Install Boards in available 5 Volt,
Compact-PCI Bus-slots.
Step 2 –Install Boards in available 5 Volt, Compact-PCI Bus-slots
IMPORTANT:Software must be installed before installing hardware.
IMPORTANT: Bus Mastering DMA must be Enabled.
For a DaqBoard/2000c Series board to operate properly, Bus Mastering DMA must be enabled.
Prior to installation, verify that your computer is capable of performing Bus Mastering DMA for
the applicable compact-PCI bus-slot. Note that some computers have BIOS settings that enable
[or disable] Bus Mastering DMA. If your computer has this BIOS option, ensure that Bus
Mastering DMA is Enabled on the appropriate compact-PCI bus-slot.
Refer to your PC’s owner manual for additional information regarding Bus Mastering DMA.
IMPORTANT: The Compact-PCI Bus-Slot must be keyed for 5 Volt use.
Note: The 5 Volt Key location is indicated in the first photograph on page 3.
IG-2 DaqBoard/2000c Series Installation Guide 979294 1061-0940, rev 4.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

CAUTION
Turn power OFF, and UNPLUG the host PC and externally connected equipment prior to
removing any cover plates or modules. Electric shock or damage to equipment can result even
under low-voltage conditions.
Take ESD precautions (packaging, proper handling, grounded wrist strap, etc.)
Use care to avoid touching board surfaces and onboard components. Only handle boards by their
edges or ORBs. Ensure boards do not come into contact with foreign elements such as oils, water,
and industrial particulate.
1. Turn the PC’s power OFF.
2. Turn power OFF to externally connected equipment.
3. UNPLUG the host PC and all externally connected
equipment.
4. Remove the computer’s compact-PCI bus-slot cover plate
[or remove an unwanted module, if applicable].
Refer to your PC Owner’s Manual as needed.
5. Verify that the available compact-PCI bus slot is for
5 volt applications.
The computer’s 5 volt compact-PCI bus-slots can be
recognized by a blue voltage key that is located in the
center of the slot (see figure).
6. Carefully remove the DaqBoard/2000c Series Board
from its anti-static protective bag. If you have not
already done so, write down the serial number of your
board at this time. The serial number is located on the
100-pin P4 connector.
7. With the board’s injector/ejector down, guide the board
into the PC’s slot. Note that the top and bottom edges of
the board locate in edge-guides, within the PC.
8. Push the board back into the PC to engage the board’s
compact-PCI connector with the computer’s compact-
PCI bus-slot.
9. Pull the board’s injector/ejector up. This will fully
engage the connectors.
10. Secure the board by tightening the upper and lower lock
screws.
11. Using the previous steps, install additional boards into
available compact-PCI bus-slots, if applicable to your
application.
Note: The lower lock screw is accessed through an opening
on the injector/ejector as indicated in the right-hand
figure.
Injector/Ejector and Lower Lock Screw
Voltage
Key
Compact-PCI Bus-Slot with Blue 5 Volt Identifier Key
Upper Lock Screw
Injector/
Ejector
Lower Lock Screw
(see note)
Installing a DaqBoard/2000c Series Board
Lower Lock
Screw
1061-0940, rev 4.0 979294 DaqBoard/2000c Series Installation Guide IG-3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Other manuals for DaqBoard /1000 Series
1
This manual suits for next models
4
Table of contents
Other IOtech Controllers manuals