IPOX UTP76 Series Specification sheet

Quick setup wizard
24 Ports PoE Gigabit
L3 Managed Ethernet Switch

Content
1 Product Introduction 1
1.1 Overview 1
1.2
Board Diagram
1.3 2
Product Feature
3
2
Installation 4
2.1 Shipping List
2.2
Installation Precautions
4
2.2.1 Safety Precautions 4
2.2.2 Installation Requirements 5
2.3
Installation Way
2.3.1 Rack Installation
2.3.2 Workbench Installation
2.3.3 Wall-hung Installation
3 Function Configuration Guide
3.1 Computer Requirements
3.2 Set up Network Connection
3.2.1 Set Static IP for the Management Computer
3.2.2
Confirm the Network Connection by Ping Command
12
3.2.3
Cancel the Proxy Server 12
1.4 Specification
1
2.2.3
The Requirements of Electromagnetic Environment 5
3.3
Web Page Configuration Guide 13
3.3.1 Start and Login 13
3.3.2 Change Language 14
4
6
7
7
10
10
10
10
6
2.4 Cable Connection
2.4.1 Device Connection
2.4.2 Configuration Cable Connection
2.4.3 Power Cable Connection
9
9
9
9

1.3 Diagram Board
1 Product Introduction
1.1 Overview
The switch series contain 24 ports switch(PoE and no PoE) and 16 ports
switch(PoE and no PoE).
The 24 ports PoE Gigabit managed Ethernet switch(abbreviated to 24P switch),
which provide 24* PoE Gigabit downlink Ethernet ports , 4* 10Gigabit uplink SFP
ports . The Products support IEEE 802.3 af/at ,support Web layer-3 network
management and PoE management. Products are widely used in security
surveillance, network engineering projects and so on.
The 16 ports PoE Gigabit managed Ethernet switch(abbreviated to 16P
switch),is similar to 24P switch;only the downlink ports quantity is 16,and the
power watts is 320W but the 24P switch’s is 450W.The 24P switch as an example
to introduce below.
1.2 Product Feature
provide 24* PoE Gigabit downlink Ethernet ports , 4* 10Gigabit uplink SFP
ports ;
Provide web-based layer 3 network management and PoE management
by simple operation;
Support high-speed data forwarding, very suitable for large flow of video data
forwarding in security surveillance;
Support recovery of IP address & user password by one key recovery button;
Quick Installation, simple operation, convenient for wall/desk/rack
installation.
12
The front panel
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
135 7 911 13 15 17 19 2123 1
246810 12 14 16 18 20 22
3
2
2×10GBA SE-X
2×10G BASE -X
Powe r1 2
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
135 7 911 13 15 1
246810 12 14 16
3
2
2×10GBA SE-X
2×10G BASE -X
Powe r1 2
16 Ports switch(16S) ↓
24 Ports switch(24S) ↓
OOB ports
Web control
Recovery buttom
Reset to defaults
16 Ports PoE switch(16P) ↓
24 Ports PoE switch(24P) ↓
console ports
CLS control Gigabit PoE ports 10Gigabit
SFP+ ports
indicator LED
The back panel
Ground terminal
AC power input

Products are subject to change without prior notice.
3 4
2 Installation
Anti-counterfeiting label is attached to switch's cover. Product damage
caused by unauthorized disassembly is not covered under warranty.
Caution
2.1 Shipping List
2.2 Installation Precautions
To avoid device damage or personal injury by improper use, please observe the
following precautions.
P
contact your local dealer.
lease check the following items before installation, if any missing, please
This is level A product, which may cause radio disturbance in living
environment. Users may need to take corresponding and effective
measures to solve the problem.
Item Name Quantity Unit
1 Switch pc
2 AC Power Line pc
4
Accessory
1 set
3
Quick setup wizard
1 pc
2.2.1 Safety Precautions
Instruction
1.4 Specification
Item
24P
16P
24S
16S
Power
Power Supply
Mains on load
Voltage Range
AC 100 240V 50/60Hz~
Consumption
450W
320W
Redundance Power
2*60W
Network
Connector
Ethernet Port
1 16/24 ports: 10/100/1000Mbps RJ45
Auto-MDI/MDI-X ports
support IEEE 802.3 af/at
~
1 16/24 ports: 10/100/1000Mbps
RJ45 Auto-MDI/MDI-X ports
~
Uplink:10GEBase-X SFP+ Module ports
support 1000Base X,setup the " ports settings " on Web management-
Transmission
Distance
Ethernet ports:100m
SFP ports: depend on SFP module
PoE
Sigle port<30W
Whole<390W
Sigle port<30W
Whole<270W
N/A
Network
Switch
Network Standard
IEEE802.3,IEEE802.3u,IEEE802.3ab,IEEE802.3z,IEEE802.3X,IEEE
802.1Q,IEEE 802.1p,IEEE 802.3ad,IEEE802.3ae
Switch Capacity
24P and 24S 128Gbps;16P and 16S 112Gbps
Packet Buffer
12Mb
Packet Forwarding
Rate
24P and 24S 95.2Mpps;16P and 16S 83.3Mpps
MAC Address
16K
Manageme
nt
Management
Management L3 + PoE
Protection
ESD
6KV/8KV Per:IEC61000 4 2- -
Lighting Protection
6KV Per: IEC61000-4-5
Environme
ntal
Working Temperature
-10 ~45℃℃
Storge Temperature
-~40 85℃℃
Humidity(non-
condensing)
0 95%~
Mechanica
l
Dimension(LxWxH)
442mm×315mm×44mm
Material
Sheet Metal
Color
Black
Weight
4.5kg
1
1*
* the 24S and 16S switch have redundance power module, including 2 AC
power lines.

5 6
Figure 2-1 Install hangers diagram
Pull out the power plug before cleaning the switch. Do not use wet cloth nor
liquid to wipe or wash the switch;
Do not leave the switch close to water or wet place so as to prevent water or
dampness from entering into the switch;
Make sure the switch work in a clean environment. Excessive dust may
cause electrostatic adsorption, which will affect the equipment life and cause
communication failure;
The switch will work normally under the correct voltage. Please ensure the
voltage indicated on the switch corresponds to the power voltage;
To avoid the danger of electric shock, please do not open the switch case.
Do not open the switch case even if the switch is powered off;
The accessories (including but not limited to power cables, etc.), which can
be used for the switch only, is prohibited for other applications.
The device should work in indoor environment to avoid thunder stroke. It is
important to obey the following requirements no matter you install it in the
cabinet or on the workbench directly:
Enough space (larger than 10cm) for air outlet so as to facilitate the
heating dissipation; Good ventilation system for cabinets and workbench
is preferred;
Ensure the Cabinet and workbench is sturdy enough to support the
switch and it’s accessories’s weight;
Cabinet and workbench with good grounding is preferred.
When it is working, the switch may be affected by external interference outside
the system through the ways of radiation and conduction. Please pay attention
to the followings:
AC power supply is TN system, so it is necessary to use single phase power
socket (PE) which can protect ground wire so that the filter circuit can
effectively filter out the power grid disturbances;
The switch should work far away from high-power radio transmitters, radar
transmitters, high-frequency devices;
Use electromagnetic shielding if necessary, such as shielded cable;
Interface cables should be arranged indoor rather than outdoor to prevent
over-voltage or over-current damage to the signal port.
2.2.2 Installation Requirements
2.2.3 The Requirements of Electromagnetic Environment
The diagram is for reference only, the products are subject to actual
product.
2.3 Installation Way
2.3.1 Rack Installation
There are 3 installation ways: rack, workbench and installation. wall-hung
Installation process:
(1) Check rack with good grounding and stability;
(2) Use screws to fit hangers at the device board side;
Please pull out the power plug before installing or moving the switch.
Grounding and anti-lightening can greatly increase the protection level of the
switch. please connect the grounding terminal to the earth area by using at
least wire 20.
Caution
Instruction
(3) Put the device on the rack’s bracket and move the rack along the slot to
proper position ;
(4) Use screws to fit the installation hanger at rack’s fixed slot, make sure the
device is installed at rack’s bracket steadily.

7 8
Figure 2-2 Install switch to the rack
This product’s fixing hangers are just to fix the switch rather than support
it. Use brackets under the device (fixed to the rack) to support switch
when install the switch to the rack.
Instruction
2.3.2 Workbench Installation
2.3.3 Wall-hung Installation
You also can put the product on clean, steady vertical wall. Installation
procedure is below:
(1) Use the screws to fix the hangers;
You can put this product on clean, stable, grounded workbench. The installation
procedure as below:
(1)Carefully put the device upside down, clean the grooves on the chassis
backplane with soft cloth to make sure there is no oil or dust in it;
(2)Remove the stickers on the foot pad, paste the foot pad in backplane groove;
(3)Carefully put the device upright on the workbench.
Figure 2-3 Hangers installation diagram
Figure 2-4 Fix the switch on wall
(2) Drill holes on the strong position of wall and then drive the rubber plug into
the hole;
(3) Drive these screws into the hole for the rack and fix the product by aiming at
the rubber plug .

9 10
2.4 Cable Connection
2.4.1 Device Connection
U s e c r o s s n e t w o r k c a b l e o r c r o s s - o v e r c a bl e t o c on n e c t P C o r
other device with switch's Ethernet port;
2.4.2 Configuration Cable Connection
If web management,use a network cable to connect the OOB port and the
computer ’RJ45 port;
If CLS management,use a console cable to connect the Console port and
the computer’serial port(DB9);
as the following figure:
Figure 2-5 Connect configuration cable
2.4.3 Power cable Connection
Figure 2-6 Connect power cable
(1 Connect one side of switch’s power cable with the switch's AC power port,
and connect the another side with external AC power socket;
heck if switch's AC power LED is on, that means
power connected correctly;
)
(2)Turn on the power ,c
(3)Use the power plug snap to jammed the AC Power cable.
3.2.1 Set Static IP for the Management Computer
Operation steps (take Windows XP as sample):
3.1 Computer Requirements
Make sure the management PC has already been installed with Ethernet adapter;
3.2 Set Up Network Connection
(1) You need to set the IP of the PC and the switch in the same
network segment. The default IP address of the switch is 192.168.1.200,
network gate is 255.255.255.0.
(2) The port to connect management PC for Web setting must be
management VLAN. By default, management VLAN is VLAN 1,and each
port of the switch is VLAN1.
(3) If you need to connect the remote network, please make sure the
management PC and the router can do the job above.
(4) This product can't assign the IP address for the management PC, you
need to set the management static IP by yourself.
3 Function Configuration Guide
(1) Click <start> to enter the [start]
menu, select “control panel”. Double
click “network connection” icon,
double click the “local connection”
icon, pop out “local connection
status” window.
Use network cable connect Ethernet ports with network card of PC(Except the
console port).
Instruction

11 12
(2) Click <property> button, enter "local
connection property" window.
DNS server address can be empty or be filled in with the real server
address.
Instruction
(3)Select "Internet protocol (TCP/IP),
click <property> button, enter”Internet
protocol (TCP/IP) property” window.
Select “ use the IP address below”
button, input IP address ( use arbitrary
value between 192.168.1.1~
192.168.1.254, besides 192.168.1.200)
and the subnet mask(255.255.255.0).
Click "OK" to finish the configuration.
3.2.2 Confirm the Network Connection by Ping Command
Operation Steps below:
(2) Input "ping 192.168.1.200", click
<confirm> button. If there is equipment
response show in the pop out dialog,
that means network connection succeed,
otherwise please check if the network
connection is correct.
(1) Click <Start> button to enter [Start]
menu, select [Run], pop out the dialog.
3.2.3 Cancel the Proxy Server
If this management PC use proxy server to visit the internet, then you must prohibit the
proxy service, following is the operation:
(1) In browser, select [ tool/Internet
option] enter [Internet option] window.

13 14
(2) Select “connection” tabs in [Internet
option] window, and click [LAN Setting]
button.
(3) Make sure the “Use proxy server for LAN”option is not selected. If selected, please
cancel it and click <yes> button.
The menu bar has the following options: [System Status], [Port Configuration],
[VLAN Settings], [QoS management], [link management], [Port Security],
[network management], [Network Statistics], [System management], [Exit] and
drop-down menu bar of the "language switching function". Click a option to
make corresponding setting. The following will explain the function of each
option.
3.3 Web Page Configuration Guide
3.3.1 Start and Login
This product web default IP address:
1 9 2 . 1 6 8 . 1 . 2 0 0 , s u b n e t m a s k :
2 5 5 . 2 5 5 . 2 5 5 . 0 , a d m i n i s t r a t o r
account: admin, password:admin.
A f t e r i n s t a l l i n g t h e e q u i p m e n t
correctly and setting up the computer,
open the browser, input the switch
d e f a ul t a d dr es s i n t h e b r ow se r
address bar: ,
then press the Enter key, the user
login page will show in front of you as
follows:
http://192.168.1.200
The browser version recommend:IE7 and later, Firefox browser, Chrome, 360
browser (IE7 and later).
Please follow the steps to check if the switch is installed correctly:
(1) Whether the physical connection of the equipment is correct?
the link
LED of the port is on.
(2) Whether the computer TCP/IP agreement setting is correct?
~
(3) Whether
same as each port of switch.
Use network cable to connect the product’s Ethernet port(except the
console port) with managed computer network card, and ensure
Your computer's IP address must be 192.168.1.x (x range is 1 254 and x
can not be 200, otherwise it will conflict with the product IP address
192.168.1.200 ), subnet mask: 255.255.255.0.
the computer's port VLAN ID is 1?
By default, the management VLAN is VLAN 1,
After inputting the correct password, click <Login in>, the browser will display
the product Web management page as the picture below:
Caution
As shown below, in the upper right corner of the Web page, click on the drop-
down menu bar, select [Chinese] or [English], to complete Web language
switching.
3.3.2 Change Language
Web management page diagram
Web English language switching page diagram

This product design is environmental friendly and the product should be stored,
used and dicarded in accordance with relevant national legal / regulatory
requirements.
En v i ronm e n t prot e c tion
15
This manual suits for next models
2
Table of contents
Popular Switch manuals by other brands

Siemens
Siemens SIMATIC NET SCALANCE X005TS Commissioning manual

UPOWER
UPOWER A03-ATS16A user manual

Marmitek
Marmitek Connect 310 UHD 2.0 user manual

Costar Video Systems
Costar Video Systems CRIS12 Operation manual

Mellanox Technologies
Mellanox Technologies MSX6536-10R Hardware installation guide

Avocent
Avocent DSR Series DSR1020 Firmware release notes