IQ-group E-808 Assembly instructions

INSTALLER GUIDE
PIR Motion Detector
E-808
Version 2 : 02/05
IQ-SA-180-D-GR
IQ Europe Limited
Sandbeck Lane, Wetherby LS22 7TW.
Visit us at www.iq-europe.co.uk
Installation helpline 0871 717 1100
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 1

MANUFACTURER'S EXTENDED WARRANTY
In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe)
Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship
which affect its designed ability to detect or switch. During this period if the product has a defect
of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar
one of higher specification, ON CONDITION THAT:-
The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is
bought.
If the product has a defect outside the period of any seller's 'return to store' scheme it should be
returned to IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England
at the expense of the buyer together with evidence of the date of purchase (it is the responsibility
of the buyer to prove delivery to IQ).
The product has been bought by the user.
The product has not been misused or handled carelessly, installed incorrectly, or used on a
voltage supply other than that shown on it.
Repairs have not been attempted by anyone other than IQ's staff.
The product has been used for domestic purposes only.
The product has not been installed in any unusually exposed or harsh environmental conditions.
If the buyer is resident in the EU the product or its replacement will be returned to the buyer at
the expense of IQ.
This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable
parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other
than those expressly set out above and does not cover any claims for consequential loss or
damage.
This guarantee is offered as an additional benefit and does not affect your statutory rights as a
consumer.
This contract is subject to the laws of England and Wales.
*** IMPORTANT ***
As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in
England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical
system, but the work must be done in accordance with the Regulations.
Where you employ an electrician who is a member of a competent person self-certification scheme, they
will be able to certify the work complies with the Regulations.
If you decide to carry out the work yourself we recommend that you make yourself aware of the
Regulations before you begin and if you require any clarification you should contact your Local Authority
Building Control Department.
Details of the Building Regulations can be obtained on the internet via the government website
www.odpm.gov.uk/explanatory-booklet
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 2

SECTION ONE
GENERAL INFORMATION
The unit utilises passive infrared technology to detect heat radiation of moving human bodies.
The dual output facility operates the attached lighting load at two light levels during the hours of
darkness: high power security output when it senses movement within its detection field,
dimmable courtesy output to provide an attractive low level of light when no movement is
detected.
PARTS INCLUDED
- PIR Sensor unit.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack.
TOOLS & PARTS NEEDED
- 3 core flexible cable
- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver
- Large slotted/philips screwdriver
- Wire cutters
This product is suitable for wall or ceiling mount.
Lighting loads connected must not exceed maximum 1000W tungsten halogen (security output)
and 120W incandescent (courtesy output). It is not recommended to use this product with
compact fluorescent energy saving lamps.Do not attempt to install during wet weather, if you are
suffering from nausea or dizzy spells or on medication with similar side effects.If in any doubt,
consult a qualified tradesperson or electrician.
SECTION TWO
SELECTING THE LOCATION
The motion detector has a number of detection zones, at various vertical and horizontal angles
as shown (see diagram A).
A moving human body needs to cross/enter one of these zones to activate the sensor. The best
all-round coverage is achieved with the unit mounted at the optimum height of 2.5m.
Careful positioning of the sensor will be required to ensure optimum performance. See diagram
A detailing detection range and direction.
The sensor is more sensitive to movement ACROSS its field of vision than to movement directly
TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the
likely approach path.
Avoid positioning the sensor where there are any sources of heat in the detection area (extractor
fans, tumble dryer exhausts etc.) including opposite any other light sources such as other
security lights.
Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may
cause false activation under extreme conditions.
During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does
not indicate a fault with the sensor. Once normal weather conditions return, the sensor will
resume normal operation.
LIGHT POLLUTION
To reduce the risk of light pollution, consider the following when installing the any lights controlled
by this unit.
Position the light to ensure that the light emitted does not encroach onto neighbouring properties.
Angle the floodlight downward to focus the illumination onto the ground, not into the sky.
Consider using a lower wattage bulb (200W, 300W) to save energy and reduce high light output if
not required.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 3

GB
SECTION THREE
INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows:
The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to
switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not
required or for maintenance purposes.
This product is designed to be mounted on walls or under eaves, see diagram E. The sensor can
be rotated through 180 degrees to direct detection where required, decide on your location before
installation.
Remove the unit from its packaging.
Unscrew the wiring box fixing screw shown on diagram F. This screw is captive, do not fully
remove.
Detach the wiring box from the Sensor body.
Using the wall plate as a template, mark the position of the fitting holes.
Drill the holes. Insert the wall plugs into the holes.
PIERCE & PASS THE CABLE(S) THROUGH THE GROMMET(S) BEFORE PROCEEDING.
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal.
Attach the mounting plate to the wall using screws provided. Do not overtighten the mounting
screws as this could damage the unit. If using a power screwdriver, use the lowest torque
setting.
This unit features an installation aid. Simply hang the Sensor onto the wall plate by use of the clip
arrangement on the wall plate. See diagram H. This allows you to use your hands to hold the
screwdriver, and install the incoming cables with ease.
Connect the incoming and outgoing cables as follows
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or switching off
the circuit breaker before proceeding with the installation.
CONNECTION
Connect the mains supply cable to the terminal block on the unit as follows (see connection
diagram): NEUTRAL (Blue) N
EARTH (Green/Yellow)
LIVE (Brown) L
Connect the cable from the lighting load(s) to the terminal block on the unit as follows (see
connection diagram):
Security Output Courtesy Output
NEUTRAL (Blue) N NEUTRAL (Blue) N
EARTH (Green/Yellow) EARTH (Green/Yellow)
LIVE (Brown) L1 LIVE (Brown) L2
Ensure that all connections are secure.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 4

CONNECTION DIAGRAM
Isolation
Switch
Mains
Supply
Ensure that all connections are secure.
Ensure the terminal block is attached to its mounting posts in the sensor body.
Un-hook the sensor unit from the wall plate and re-attach to the wall plate box as follows:-
Ensure no wires are trapped.
Align the sensor centrally over the wiring box and attach the top edge of the sensor to the wall
plate. see diagram I. There will be an audible click indicating that the top clips are located into the
wallplate.
Slowly rotate the sensor body downwards and and ensure no wires are trapped, the lower edge of
the unit will locate into the wallplate.
Fullly tighten the fixing screw. See diagram F.
Installation is complete.
MANUAL OVERRIDE MODE
The light can be switched on for longer time periods by use of the Manual Override Mode. This
can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker off/on off/on within 1 second. The unit will now
illuminate continuously until dawn or until it is switched back into Auto Mode.
To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker off/on once
within 20 seconds. The unit will return to Auto Mode.
Security
Load
Max 1000W
Courtesy
Load.
Max 120W
Common
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 5

TOP VIEW
180º
SIDE VIEW
12m
2.5m
A C
Less
sensitive
More
sensitive
B D
Lens Mask
Restrict long detection Restrict short detection
Restrict RHS detection Restrict LHS detection
Dusk Time
DIM
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 6

SECTION FOUR
OPERATION AND TESTING
WALK TESTING PROCEDURE
The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in
the desired direction.
Set the adjustment controls on the underside of the unit (diagram C) to the following positions:
DUSK - Fully clockwise
DIMMER - Fully anti-clockwise
TIME - Fully anti-clockwise
The unit will now operate during daytime as well as at night, illuminating the lamp at full power for
approx. 5 seconds each time. This allows testing to be carried out to establish the best position
for the sensor.
The lamp will immediately illuminate as the unit goes through its "warm-up" period. After
approximately 1 minutes the lamp will extinguish. Try to remain outside the detection area during
the warm-up period.
Walk across the detection area approx 5 metres from the unit. As you cross a detection "zone"
the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5
seconds).
Start moving again. As you cross each "zone" the lamp will illuminate.
Repeat the above, walking at various distances and angles to the unit. This will help you to
establish the detection pattern.
If the detection area is too small for your requirements, try angling the sensor head up. This will
increase the coverage distance. Angling the head downwards will reduce the range should a
smaller coverage area be required.
SETTING UP FOR AUTOMATIC OPERATION
When walk tests are complete, the unit can be switched to automatic operation :
The TIME setting controls how long the unit remains illuminated following activation & after all
motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the
maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting
between these limits.
The DIMMER control determines the brightness of the lamp in the dimmed mode. Set the control
between minimum (fully anti-clockwise, dimmer OFF) and maximum (fully clockwise, 60% output)
at the desired level.
The DUSK control determines the level of darkness required for the unit to start operating. The
setting is best achieved by the procedure below:
Set the DUSK control knob fully anti-clockwise. The unit will now start operating at dusk.
If you require the light to activate earlier, wait until the ambient light level reaches the level of
darkness at which you wish the lamp to become operative, SLOWLY rotate the control in a
clockwise direction until a point is reached where the lamp illuminates. Leave the control set at
this point.
At this position, the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie.
when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late
(ie. dusk), adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 7

SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
Dimmer adjustment
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
Warranty
Up to 12 metres
180º
240 V AC ~ 50Hz
1000W Tungsten Halogen (Security Output)
120W Incandescent (Courtesy Output)
0 to 60% of maximum output
5 seconds - 5 minutes
Day & night or night only operation
IP44 (suitable for outdoor use)
12 months
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to store.
Telephone the IQ Customer Helpline
0871 71 71 100 Weekdays 9.00am - 5.00pm
[email protected] www.iq-europe.co.uk
Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 8

SECTION SIX
TROUBLESHOOTING GUIDE
PROBLEM
oLamp stays ON all the time at
night.
oPIR keeps activating for no
reason / at random.
oPIR sensor will not operate at
all.
oThe PIR sensor will not
operate at night.
oUnit activates during the
daytime
oPIR coverage is poor/sporadic
o Detection range varies from
day to day
SOLUTION
Cover PIR lens with a thick cloth. If the light turns out, check
detection area for heat or reflective source.
If the light stays on, check wiring. See Section 3.
Reset unit. Leave for a maximum of 5 minutes. If light
activates, check area for false activation from heat or
reflective source.
Check that the power is switched ON at the circuit
breaker/internal wall switch.
Turn OFF the power to the unit and check the wiring
connections.
Check the lamp. If the lamp has failed, replace. Ensure that
the lamp is seated correctly in the lampholder. Please note
that the unit will not detect through glass.
The level of ambient light in the area may be too bright to
allow operation at the current DUSK setting. During the hours
of darkness, adjust the DUSK control slowly clockwise until
the lamp illuminates. Refer to previous section for more
details.
Adjust the setting anti-clockwise to lower the level of ambient
light required for activation.
Unit may be poorly located. See previous section - ‘Selecting
The Location’ and re-locate the unit.
PIR sensors are influenced by climatic conditions. The colder
the ambient temperature, the more effective the sensor will
be. You may need to make seasonal adjustments to the
sensor head position to ensure trouble-free operation all year
round.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 9

E
G
Wall Mount Ceiling or eave mount
180 degree rotation
of sensor head
ensures accurate
detection control
Wiring Box fixing
screw.
F
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 10

H
I
Installation aid. Clip main
body onto wall plate for
easier wiring
Extra view shows detail of
clip arrangement
1. Align top edge and “click
2. Rotate sensor body down and
“click” lower edge into place
Fully tighten sensor fixing screw
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 11

?
DID YOU KNOW...
IQ products are designed and manufactured to give many
years of trouble-free service.
The materials used during manufacture have been
selected to allow the product to be easily recycled when
no longer functional.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling
advice
LIGHT POLLUTION & CONSIDERATE LIGHTING
Please be aware of the annoyance over-lighting an area
can cause to your immediate neighbours.
Light pollution caused by incorrectly installing a unit or
over-lighting an area can be limited by carefully considering
the location and position of your unit before installation. The
light spread on all halogen floodlights can be reduced by
angling the floodlight downwards on the mounting bracket.
This will also concentrate the light on your property and
limit the potential inconvenience of the light shining into
your neighbours windows etc.
Please see Selecting a Location for information on
choosing the optimum location for your security light.
SF-SA-180-D PIR HiLo 10A.qxd 16/05/2005 11:17 Page 12
Table of contents
Other IQ-group Security Sensor manuals
Popular Security Sensor manuals by other brands

B.E.G.
B.E.G. LUXOMAT PD11-KNX-FLAT-DX Short manual

INTERTECHNO
INTERTECHNO PIR-3000 operating instructions

IFM
IFM OJ50 laser Series operating instructions

Intelbras
Intelbras IVP 4101 PET user manual

Sierra Monitor Corporation
Sierra Monitor Corporation 3600I instruction manual

Jabra
Jabra NOISE GUIDE quick start guide