4
NOTE
Installation Guidelines
1. Recommended Mounting Information
54.3”
(138cm)
61”
(155cm)
This is based
on the assumption
that users’ average
height is 5‘7”(170cm)
Floor
Bottom of
Mirror
7.01”
(178mm)
8.31”
(211mm)
2.52”
(64mm)
NOTE
NOTE
2. General Wiring Requirements
Ethernet network wiring to connect with the network switch for communication.
Power Wiring: The minimum recommended wire gauge used for power is 16AWG (1.0mm )
Power Requirements: 12-24VDC +/- 10% / Minimum 24W (12VDC @ 2AMPS)
The iCAM7000 series requires at least the following wires:
2
IMPORTANT: IT IS RECOMMENDED THAT THE IRISACCESS SYSTEM BE PLACED ON A PRIVATE NETWORK
SEPARATE FROM GENERAL CORPORATE OR PUBLIC ACCESS. SYSTEM PERFORMANCE AND STABILITY MAY BE
AFFECTED DEPENDING ON AMOUNT OF GENERAL NETWORK TRAFFIC.
IMPORTANT: IT IS RECOMMENDED TO SUPPLY THE CORRECT AMOUNT OF POWER TO THIS UNIT. AN OVER OR
UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.
2
The iCAM was designed for indoor use only. This device is not weatherproof and must not be
exposed to precipitation or extreme temperatures. If it is required to use this product in an
outdoor or extreme environment, a 3rd Party enclosure may be used to protect the unit from
exposure to dust, moisture, and extreme temperatures. See www.irisid.com - Support &
Service for more information. Installation in a extreme environment without proper protection
may cause permanent damage and void your warranty.
The recommended mounting height for the iCAM7000 series is 138cm (54.3inches) from the
floor to the bottom of the unit. This mounting height can be adjusted to accommodate the
height of the average user at the installed location.
High amounts of ambient light must be avoided. Intense light sources such as sunlight or
halogen lamps may reduce the image capture performance of the iCAM which may result in
an increased “failure to acquire” rate.
Use of a stable power supply and proper guage wire is required. Wire length voltage
drop must be accounted for in order to maintain the correct power at the iCAM unit (with
iCAM connected). For example; with a 12VDC source and 16AWG (1.0mm ) copper wire, the
maximum distance is 71.5 Feet (21 Meters). If a longer power wire distance is required, it is
recommended that a 24VDC power source be used. Voltages within the range of 12VDC and
24VDC are acceptable as long as 24W of power is supplied to each iCAM.
(e.g. 12VDC @ 2AMPS = 24Watts OR 24VDC @ 1AMP = 24Watts).
For systems consisting of only the iCAM and a computer, an Ethernet cross-over cable
may be used.