4 / 60
1. Before starting the MAGNUM fireplace and DM 54
chimney installation, read these installation instructions
carefully to be sure you understand them completely. Failure
to follow them could cause fireplace malfunction resulting
in serious injury or property damage.
2. Always check local building codes governing fireplaces
and fireplace installations. The MAGNUM fireplace and
DM chimney installation must comply with all local, region-
al, state and national codes and regulations.
3. MAGNUM fireplace and DM 54 chimney systems are
intended for use in any application where a traditional
masonry type fireplace would apply. The chimney system
must always vent vertically to the outside of the building.
4. Creosote and soot formation and the need for removal:
When wood is burned slowly, it produces tar and other
organic vapors which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney flue of a slow burning fire. As a result,
creosote residue accumulates on the flue lining. When
ignited this creosote makes an extremely hot fire.
Because of creosote and soot buildup it is necessary
to inspect and clean the fireplace and chimney prior to use
and periodically during the heating season. Cleaning of the
fireplace and the chimney system should be done annually at
a minimum. In colder climates, chimney cleaning may need
to be done periodically throughout the heating season.
5. Before servicing, allow the fireplace to cool. Always shut
off any electricity or gas to the fireplace while working on
it.
6. Use only solid fuel or natural or LP gas log sets in this
unit. Do not use artificial wax based logs, chemical chimney
cleaners or flame colorants in this fireplace.
7. Never use gasoline, kerosene, gasoline-type lantern fuel,
charcoal lighter fluid, or similar liquids to start or “freshen
up” a fire in this fireplace. Keep all flammable liquids at a
safe distance from the fireplace.
8. Always keep the flue damper open when heat is present
in the fireplace.
9. Do not use a fireplace insert or any other product not
specified for use with the MAGNUM fireplace and DM 54
chimney systems unless written authorization is given by
Isokern. Failure to heed this warning may cause a fire hazard
and will void the Isokern warranty.
10. This fireplace is not intended to heat an entire home or
to be used as a primary heat source. It is designed to ensure
homeowner comfort by providing supplemental heat to the
room.
11. Always ensure that an adequate supply of replacement
combustion air from the outside of the house is accessible to
the fire to support normal combustion. Fireplaces consume
large volumes of air during the normal firing process. In the
event the home is tightly sealed and has modern energy effi-
cient features, the optional combustion air supply kits may
not provide all the air required to support combustion and
the proper flow of combustion gases up the chimney.
The manufacturer is not responsible for any smoking or
related problems that may result from the lack of adequate
air supply flowing into the house. It is the responsibility of
the builder/contractor to ensure that adequate air supply has
been provided for the fireplace.
12. “Smoke free” operation is not warranted nor is the
manufacturer responsible for inadequate system draft caused
by mechanical systems, general construction conditions,
inadequate chimney heights, adverse wind conditions or
any unusual environmental conditions or factors beyond the
manufacturer’s control.
13. CAUTION:When used with the MAGNUM fireplace
system, all gas log sets must be operated with the damper
clamped in the open position. This includes unlisted “vent
free” log sets. Only listed “vent free” log sets may be oper-
ated with the damper in the closed position.
14. When in doubt about a component’s usability - has vis-
ible or suspected physical damage - consult your Isokern
distributor or authorized Isokern representative for advice.
15. Modification to MAGNUM components not mentioned
in this manual may void warranties, listings and approv-
als and could result in an unsafe and potentially dangerous
installation.
Alterations to the MAGNUM firebox are not allowed
without prior written approval and instructions from
Earthcore Industries, Inc.
16. Wherever insulation is used, the MAGNUM fireplace
must not be placed directly against it. Keep all insulation or
vapor barriers a minimum of three inches (3”) away from all
fireplace and chimney components.
It is recommended that insulation and vapor barriers, if
used, first be covered with gypsum board, plywood, particle
board or other material to assure that insulation and vapor
barriers remain in place.
17. WARNING – DO NOT PACK REQUIREDAIR SPACES
WITH INSULATION OR OTHER MATERIALS.
18. Never leave children unattended when there is a fire
burning in the fireplace.
19. Burning some fuels (such as charcoal) can be hazardous
due to the possibility of producing carbon monoxide, a col-
orless, odorless gas. Early signs of carbon monoxide poising
resemble flue symptoms, including headaches, dizziness or
nausea. Over exposure to carbon monoxide can lead to ill-
ness and death.
It is strongly recommended to install smoke and carbon
monoxide alarm / detector devices wherever fireplaces are in
use.
Safety Instructions