Safety Instructions
1. Before starting the Magnum 86072 Series replace and
DM chimney installation, read these installation instructions
carefully to be sure you understand them completely. Failure
to follow them could cause replace malfunction resulting in
serious injury or property damage.
2. Always check local building codes governing replaces and
replace installations. The Magnum 86072 Series replace and
DM chimney installation must comply with all local, regional,
state and national codes and regulations.
3. Magnum 86072 Series replace and DM chimney systems
are intended for use in any application where a traditional
masonry type replace would apply. The chimney system must
always vent vertically to the outside of the building.
4. Creosote and soot formation and the need for removal: When
wood is burned slowly, it produces tar and other organic vapors
which combine with expelled moisture to form creosote. The
creosote vapors condense in the relatively cool chimney ue of
a slow burning re. As a result, creosote residue accumulates
on the ue lining. When ignited this creosote makes an
extremely hot re.
Because of creosote and soot buildup it is necessary
to inspect and clean the replace and chimney prior to use
and periodically during the heating season. Cleaning of the
replace and the chimney system should be done annually at
a minimum. In colder climates, chimney cleaning may need to
be done periodically throughout the heating season.
5. Before servicing, allow the replace to cool. Always shut
off any electricity or gas to the replace while working on it.
6. Use only solid fuel or natural or LP gas log sets in this
unit. Do not use articial wax based logs, chemical chimney
cleaners or ame colorants in this replace.
7. Never use gasoline, kerosene, gasoline-type lantern fuel,
charcoal lighter uid, or similar liquids to start or “freshen up”
a re in this replace. Keep all ammable liquids at a safe
distance from the replace.
8. Always keep the ue damper open when heat is present in
the replace.
9. Do not use a replace insert or any other product not
specied for use with the Magnum 86072 Series replace and
DM chimney systems unless written authorization is given by
Earthcore. Failure to heed this warning may cause a re hazard
and will void the warranty.
10. This replace is not intended to heat an entire home or
to be used as a primary heat source. It is designed to ensure
homeowner comfort by providing supplemental heat to the
room.
11. Always ensure that an adequate supply of replacement
combustion air from the outside of the house is accessible to
the re to support normal combustion. Fireplaces consume
large volumes of air during the normal ring process.
In the event the home is tightly sealed and has modern
energy efcient features, the optional combustion air supply
kits may not provide all the air required to support combustion
and the proper ow of combustion gases up the chimney.
The manufacturer is not responsible for any smoking
or related problems that may result from the lack of adequate
air supply owing into the house. It is the responsibility of the
builder/contractor to ensure that adequate air supply has been
provided for the replace.
12. “Smoke free” operation is not warranted nor is the
manufacturer responsible for inadequate system draft caused
by mechanical systems, general construction conditions,
inadequate chimney heights, adverse wind conditions or
any unusual environmental conditions or factors beyond the
manufacturer’s control.
Caution: When used with the Magnum 86072 Series replace
system, all gas log sets must be operated with the damper
clamped in the fully open position. This includes unlisted
“vent free” log sets. Only listed “vent free” log sets may be
operated with the damper in the closed position.
13. When in doubt about a component’s usability - has visible
or suspected physical damage - consult your Isokern distributor
or authorized Isokern representative for advice.
14. Modication to Magnum 86072components not mentioned
in this manual may void claims, listings and approvals and
could result in an unsafe and potentially dangerous installation.
Alterations to the Magnum 86072 rebox are allowed
with prior written approval and instructions from Earthcore
Industries, LLC. The installer indemnies the manufacturer of
all claims and under no circumstances will manufacturer be
liable for consequential, incidental, indirect, punitive or other
damages of any kind or nature, whether foreseeable or not,
based on any claim by any party as to the modications of the
Isokern replaces.
15. Keep all insulation, vapor barriers, “house wrap”
paper and other insulating type membranes and products,
including berglass, cellulose and other insulation,
(anything that carries an “R” rating) a minimum of three
inches (3”) away from all rebox and chimney surfaces.
Exception:
If insulation is used in walls surrounding the replace,
insulation may be installed behind sheathing of gypsom board,
plywood, particle board or other material on the side facing
the Isokern. The facing material cannot be within 1 1/2” to the
replace sidewalls.
WARNING: Do not pack required air spaces with insulation
or other materials.
16. Never leave children unattended when there is a re
burning in the replace.
17. Burning some fuels (such as charcoal) can be hazardous due
to the possibility of producing carbon monoxide, a colorless,
odorless gas. Early signs of carbon monoxide poisoning
resemble u symptoms, including headaches, dizziness or
nausea. Over exposure to carbon monoxide can lead to illness
and death. It is strongly recommended to install smoke and
carbon monoxide alarm / detector devices wherever replaces
are in use.
6