iSolution FOLL02 User manual

Professional Intelligent Follow Spot
User Guide
Professional Entertainment Technology
1F
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
2.1 Inserting/Exchanging Rotating Gobos
2.2 Beam Angle
3. Lamp
4. How To Set The Unit
4.1 Control Panel
4.2 Main Function
4.3 Home Position Adjust
5. How To Control The Unit
5.1 Universal DMX Controller
5.2 Dedicated Controller
5.3 DMX 512 Configuration
5.4 DMX 512 Connection
6. Troubleshooting
7. Fixture Cleaning

2F
1. Safety Instruction
WARNING
♦ Please keep this User Guide for future consultation. If you sell the unit to another user,
be sure that they also receive this user guide.
♦ Unpack and check carefully there is no transportation damage before using the unit.
♦ Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the unit.
♦ It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
♦ The unit is for indoor use only and only in a dry location.
♦ The unit must be installed in a location with adequate ventilation, at least 50 cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
♦ Disconnect main power before fuse/lamp replacement or servicing.
♦ Replace fuse/lamp only with the same type. Do not use any other type of lamp.
♦ Make sure there are no flammable materials close to the unit while operating as it is
fire hazard.
♦ Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but
always by taking its base.
♦ Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature is
higher than this.
♦ Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand
during its operation. Turn off the power and allow about 15 minutes for the unit to cool
down before replacing bulb or serving as the unit could be very hot.
♦ In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.
♦ Don’t connect the device to any dimmer pack or power pack.
♦ Do not touch any wire during operation as high voltage might be causing electric
shock.
Please read the instruction carefully which includes important
information about installation
,
o
p
eration and maintenance.
3F
•Warning
♦ To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
♦ Never touch bulb with bare fingers as it is very hot after using.
♦ Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
♦ Do not start on the unit without bulb enclosure or housing are damaged.
♦ The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
♦ Do not look directly at the light while the bulb is on.
•Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any
repairs by yourself. If you need any service, please contact your nearest dealer.
•Installation
The unit should be mounted via its mounting system (as show below). Always ensure that
the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
structure to which you are attaching the unit is secure and is able to support a weight of 80
kgs for each unit.

4F
2. Technical Specification
Power supply
-AC 230V 50/60Hz
-AC 100V 50/60Hz / 120V 60Hz (Only for IF-575 version)
Lamp
- MSI 1200W/S / HMI 1200/S K SFc10-4
- HMI 575W & HTI 575W (Osram)or HMQ 575 & HMQ 575/2 (Xenpow)
Optical system
- High efficiency optical system
- High quality optical lens and dichroic colors
- Beam angle: 13°
Shutter/Dimmer
- Blackout, 0~100% smooth dimming and strobe speed variable (1~12 flashes per
second)
Movement
- Pan: 360° Tilt: 90°
Color Wheel
- 8 dichroic colors plus white color
- Rainbow effect at variable speeds
Color Temperature
- Standard 6000K, adjustable 5600K and 3200K
DMX Channels
- Standard DMX512 signal addressing and controlled by any universal DMX controller
Luminous intensity: (HMI 1200W)
Channel 1 = Shutter
Channel 2 = Iris
Channel 3 = Color
Channel 4 = Color temperature
Channel 5 = Dimmer
Channel 6 = Focus
5F
3. Lamp
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful
to the eyes and skin. The high luminance of the arc can cause severe damage to the
retina if looks directly at the lamp.
MSI 1200W/S / HMI 1200/S K SFc10-4
IF-575: HMI 575W & HTI 575W (Osram)or HMQ 575 & HMQ 575/2 (Xenpow)
1.Always switch off the main supply and never handle the lamp or luminant when it is
hot.
2.Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
3.The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp any longer than its specified life.
5. Make sure the lamp is located in the center of the reflector for the best spot.
In case of replacement of the lamp or maintenance, do not open the
fixtu
r
e within 15 minutes until the unit cools down after switchin
g
off.

6F
6. If changing the lamp, remove old lamp from lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb. Insert the new lamp in the lamp socket.
7. Please turn the head in horizontal position. Hinge must be on the upper side of the head.
Turn screws left and remove plastic cover. Loosen head screw and open the lamp cover
8. With the nipple of the lamp facing the back insert one end of the lamp into the socket. Pull
up the spring of the other side of the socket and snap the other end of the lamp into place.
Make sure it fits correctly into the socket. Please refer to the diagram to know how to put
the lamp in correct position.
7F
4. How To Set The Unit
4.1 Control Panel
Display
To show the various menu and to select functions.
Button
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
On/Off
Turns On/Off the power
Fuse
To replace the fuse
Power
To connect the power plug
DMX input/output
For DMX 512 link, use 5-pin XLR plug cable to link the unit together

8F
4.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
Lamp on
Lamp off
MENU
Self-Test
Reset
Fixture Hours
DMX512 Address Setting
DMX 512 Address Setting
Press the MENU button until the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press the ENTER button to setup or automatically
return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the MENU button again.
Self-Test
Press the MENU button until the is blinking on the display. Pressing ENTER
button and the unit will run self-test by built in program. To go back to the functions press the
MENU button again.
Fixture Hours
Press the MENU button until the is blinking on the display. Pressing ENTER button
and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button again.
9F
Reset
Press the MENU button until the is blinking on the display. Pressing ENTER button
and all channels of the unit will return to their standard position. To go back to the functions
press the MENU button again.
4.3 Home Position Adjust
Press MENU button for at least 5 seconds into offset mode to adjust the home position,
when you want to adjust gobo and color home position, you should be run mode
first , the functions are shown below:
Color offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the color home position. Once the color has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
Effect offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the is shown on the display. Pressing ENTER button and the display
will blink. Use DOWNand UP button to adjust the effect home position. Once the effect has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.

10F
Dimmer offset
Press the MENUbutton for at least 5 seconds into offset mode, use DOWN and UP button
up to when the is shown on the display. Pressing ENTER button and the display will
blink. Use DOWN and UP button to adjust the dimmer home position. Once the effect has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
5. How To Control The Unit
Two ways to operate:
1. By universal DMX controller
2. By dedicated controller
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show 1200 on the
display and move all the motors to their ‘home’ position and you may hear some noises for
about 20 seconds. After that the unit will be ready to receive DMX signal.
5.1 DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from
1 to 512 channels so that the units can receive DMX signal.
Press the MENUbutton up to when the is shown on the display. Pressing ENTER
button and the display will blink. Use DOWNand UP button to change the DMX512 address.
Once the address has been selected, press and keep ENTERbutton pressed up to when
the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the MENU button again.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
6 Channels:
11F
5.2 Dedicated Controller
IF-series has 6 channels for international protocol DMX512. It can finish all operations via
dedicated controller without using other controllers. When the power is switched on, the
projector automatically starts to run the self-test. After finishing these, the fixture is ready for
operation.
1. DIMMER OPEN buttons: Holding the buttons, the light beam will become more stronger
and stronger, then shutter will obtain max. value. After un-holding it, the light beam and
shutter resumes its initial condition. There are 2 buttons on the both sides of the controller
for your convenient operation.
2. IRIS OPEN buttons: Holding the buttons, the light iris will become more bigger and
bigger. After un-holding it, the light beam resumes its initial condition. There are 2 buttons
on the both sides of the controller for your convenient operation.
3. FIXED COLOURS & RAINBOW switch: Turning the switch on the RAINBOW position,
enable the rainbow function, you can set different rainbow speed by pressing COLOUR
buttons from slow to fast. Turning the switch on the FIXED COLOURS position, enable
the fixed colors function and disable the rainbow function. They will save last setting
automatically in each step.
4. COLOUR buttons: There are 9 color buttons of white, red, yellow, magenta, green,
orange, blue, pink and purple. Select the light beam colors by pressing the relative color
buttons.
5. COLOUR TEMPERATURE switch: Adjusting this switch to obtain 3 kinds of color
temperature: Standard 6000K, 5600K and 3200K.

12F
6. DIMMER slider: Adjusting the slider from 0% to 100% position, the light beam will
become more stronger and stronger till the dimmer reach 100%.
7. SHUTTER slider: Adjusting the slider from slow to fast position, the strobe speed will
become from slow to fast.
8. IRIS slider: Adjusting the slider from min. to max. position, the light beam size will
become more bigger and bigger till the iris opened fully.
9. FOCUS slider: Adjusting the suitable focus by pushing this slider from left to right.
65. 3 DMX512 Configuration
13F
5.4 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in
the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a
very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4. The DMX signal is able to pass through each fixture continuously, so if one fixture in the
chain is out of order, all the fixtures after this point will not be affected.
5. Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

14F
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. Check the address settings and DMX polarity.
2. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
3. Try to use another DMX controller.
4. Check in the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1.The lamp is not working well. Check the main voltage either too high or too low.
2.Internal temperature may be too high. Check and if necessary replace the fan.
15F
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
EC-Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN 60598-1: 2004
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test
Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC

16F
Technical Specifications
Power AC 230V~50/60Hz
AC 100V~50/60Hz or 120V~60Hz (only for HMI 575W version)
Fuse 6 x 30 mm Glass T15A (HMI-1200W version)
6 x 30 mm Glass T10A (HMI 575W version)
Lamp MSI 1200W/S / HMI 1200/S K SFc10-4/ HMI 575W
Dimension 1170 x 330 x 225 mm
405 x 360 x 35 mm (Controller)
Weight 42.4 kg (HMI-1200W version)
38 kg (HMI 575W version)
17F
Innovation, Quality, Performance.
Table of contents
Other iSolution Floodlight manuals
Popular Floodlight manuals by other brands

Eaton
Eaton Crouse-hinds series Installation & maintenance information

Chauvet
Chauvet Intimidator Beam LED 350 user manual

Probrite
Probrite Fusion X FSNX15-5CCT-BZ INSTALLATION, USAGE, & CARE GUIDE

Elumen8
Elumen8 ELUM054A Plasma 3K RGB user manual

Martec
Martec Defender MLDXD3451M quick start guide

RS PRO
RS PRO 791-8264 instructions