1. General Instructions
The following points are important for safety as well as for the smooth installation and
performance of the unit.
Unpack carefully and be sure that no damage has occurred during shipping.
It is very important to ground the yellow/green conductor in order to meet regulations for
safety.
Do not connect the device to any dimmer pack or power pack.
The electrical work that is necessary for installation must be done by qualified
personnel .
Be sure to locate the unit in a place with adequate ventilation at least 15 cm from the
walls and at least 100 cm from adjacent surfaces. Be sure that no ventilation slots are
blocked.
Be careful that no liquids or other objects can enter the unit. If this ever happens,
disconnect the main power immediately.
In the event of serious operating problems, turn off the unit immediately. Never try to
repair the unit yourself. Repairs carried out by non-qualified personnel can lead to
serious damage or malfunction. Please contact your dealer about authorized technical
assistance. Always use genuine spare parts.
Occasional breaks are necessary to prevent breakdowns. This unit is not designed to
be used non-stop.
Always remember to unplug the unit from the power mains before any service is done.
Please recycle the packaging.
3 A
2. Main Features
Voltage:AC 120V 60Hz or 230/240/250V 50/60 Hz
•Bulb:J Type 230V 800W(Euro)
J Type 120V 500W(USA)
•3 dichroic mirrors red, blue, and green .
•With lamp saving switch-off function. When the unit receives stand by signal from a
easy controller or an universal DMX controller, it will switch off the lamp extending the
lamp’s lifetime.
Easy access for bulb change.
Universal DMX addressing and control.
The units can be linked together in a master/slave combination and run by built-in
programs.
Compatible with easy controller or universal DMX controller.
DMX signal / sound activation LED indicators.
Fan cooled.
•Dimension : 285 x 295 x 460 mm
Weight : 8.8 kg
3. Lamp
J Type 230V 800W(Euro)
J Type 120V 500W(USA)
•Always switch off the mains supply and never handle the lamp or luminaire when
it is hot.
•Do not touch the bulb with bare hands. If this does happen, clean the lamp with denatured
alcohol and wipe with a lint free cloth before installing.
•Change lamp:
Take off the dichroic glass as showing and change
the lamp. Re-screw the glass after changing the
lamp.
G
R
B

4 A
4. How To Set The Unit
4.1 Control Panel
DOWN UP ENTER
MENU
DMX
MASTER
SLAVE
SOUND
MIC ONLY FOR REMOTE
CONTROL(CA-8)
DMX IN DMX OUT
Display
To show the various menus and the selected functions .
LED
DMX On DMX input present
MASTER On Master Mode
SLAVE On Slave Mode
SOUND Flashing Sound activation
Button
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
Remote controller input
By connect to the 1/4” microphone jack to control the unit for stand by, function and mode
Microphone
To receive audio signal for sound activation .
DMX input/output
For DMX512 link, use 3-pin XLR plug cable to link the unit together.
5 A
4. 2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
Dimmer Inversion
Dimmer Normal
Setting 3 Channel
Setting 4 Channel
Blackout Mode " Yes Blackout "
Blackout Mode " No Blackout "
DMX512 Address Setting
Display Normal
Display Inversion
Reset
MENU
Fixture Hours
LED off
LED on
DMX512 Address Setting
Press the MENU button up to when the is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to change the DMX512
address. Once the address has been selected, press the ENTER button to setup or
automatically return to the main functions without any change after 8 seconds. To go back to
the functions without any change press the MENU button again.
Channel Mode
Press the MENU button up to when the is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (4
Channel ) or (3 Channel) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change
after 8 seconds. To go back to the functions without any change press the MENU button
again.

6 A
Blackout Mode
Press the MENU button up to when the is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(yes blackout) or (no blackout) mode. Once the mode has been selected, press
the ENTER button to setup or automatically return to the main functions without any change
after 8 seconds. To go back to the functions without any change press the MENU button
again.
Dimmer Inversion
Press the MENU button up to when the is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (normal)
or (dimmer inversion) mode. Once the mode has been selected, press the ENTER
button to setup or automatically return to the main functions without any change after 8
seconds. To go back to the functions without any change press the MENU button again.
Led Display
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (Led on)
or (Led off) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To
go back to the functions without any change press the MENU button again.
Display Inversion
It is good for you to install the unit on the floor or under ceiling. Press the MENU button up to
when the is blinking on the display. Use the ENTER button to change to the mode
(display inversion), It will automatically store after 8 seconds. Or press the ENTER
button again return to the mode (display normal). To go back to the functions press
the MENU button again.
Display normal mode for the fixture putting on the floor.
Display inversion mode for the fixture fixing under ceiling.
7 A
Fixture Hours
Press the MENU button up to when the is blinking on the display. Pressing ENTER
button and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button again.
Reset
Press the MENU button up to when the is blinking on the display. Pressing ENTER
button and the fixture will be reset. To go back to the functions press the MENU button
again.
5. How To Control The Unit
You can operate the unit in four ways:
A. By master/slave preprogrammed function
By linking the units in master/slave connection, the first unit will control the other units to
give an automatic, sound activated, synchronized light show. This function is good when you
want an instant show. Its DMX input jack will have nothing plugged into it, and Its master
LED will be constantly on and sound LED will flash to the music. The other unit’s DMX
cables plugged into the DMX input jacks (daisy chain) and the slave led lights will constantly
on.
B. By easy controller(CA-8 & CA-8F)
The easy remote control is used only in master/slave mode. By connecting to the 1/4”
microphone jack of the first unit, you will find that the remote control on the first unit will
control all the other units for Stand by, Function/Mode.
Stand By Blackout the unit
Function 1. Synchronous Strobe
2. 2-light Show Strobe Full on/Color selection
(Hold on 3 seconds for full on) Dimmer
Mode Sound(LED Off) Manual(LED On) Latch(LED blinking)

8 A
C. By Colormix controller
By link the Colormix controler to the unit , you have to use 3 pin XLR cable and use 5
pin XLR cable between Colormix controller and Colormix foot controller.
CA-32
•A professional, user friendly DMX 4ch.controller for colorimixing.
•Equipped with 9 different hold-color buttons for instant access of colors.
•Comes with 32 spectrum mix colors, color fade, and 12 different chase patterns.
•Providing the richest changing colors for the show.
•Speed and dimmer adjustable for both color fade and chase.
•Sound activated function is available.
•Full on and Blackout functions .
CA-32F
•Colormix Foot controller is a extended controller of Colormix.
•To be liked with Colormix. Add a switch to change the control between Colormix and
Colormix Foot Controller.
•Mode i.) Blackout (LED on)
ii.) Hold Color(LED off)
iii.) Chase (LED blinking)-Stamp on the button over 2 seconds for chase
•Up and Down buttons:To select the hold colors and chase patterns.
•Full on: Stamp the button for full on.
9 A
D. By universal DMX controller
If you use a universal DMX controller to control the units, you have to set DMX address from
1 to 512 channel so that the units can receive DMX signal.
Press the MENU button up to when the is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press and keep ENTER button pressed up to when
the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the MENU button again.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
4 Channels:
3 Channels:

10 A
•DMX512 Configuration
You can select 4 or 3 channels mode.
4 channels:
If you use CA-32 Colormix controller, the DMX value range of CH4 is from 100% to 0% .
3 channels:
11 A
6. DMX Link & Controls
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in
the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a
very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit,
even when one of the units in the chain is power disconnected.
5. Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

12 A
7.Troubleshooting
Following are a few common problems that you might encounter, and suggestions
as to how to solve them.
A. No light
1.Check the power on LED and fuse
2.Check the lamp if it is ok? (The lamp may turn off, when the unit is in blackout mode).
B. Not responding to DMX
1.Check if the red LED is on, if not, check DMX connectors, cables and to see if they are
linked correctly.
2.If the red LED is on and no response to the control, check the dipswitch settings and
DMX polarity.
3.If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4.Try to use another DMX controller.
5.Check if the DMX cables run near or run alongside to high voltage cables that may
cause interference to DMX interface circuit.
C. Some units don’t respond to the controller
You may have a break in the DMX cabling. The unit receiving no DMX signal will begin
its own light show. Check the red LED for the response of the DMX signal.
D. No response to the sound
1. Check the unit to make sure if it is not receiving DMX signal (red LED should be off).
2. Check the unit that is not set to auto chase mode.
3. Check microphone to see if it is good by tapping the microphone.
13 A
8. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
*Clean with soft cloth using normal glass cleaning products.
*Always dry the parts carefully.
* Clean the external optics at least once every 20 days. Clean the internal optics at least
every 30/60 days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL:2000+A12:2002
Safety of household and similar electrical appliances
Part 1 : General requirements

14 A
15 A
Technical Specifications
Power AC 120V 60Hz AC 230/240/250V 50/60Hz
Fuse 6X30mm Glass T15A
Lamps J Type 120V 500W J Type 230V 800W
Dimension 295mm x 285mm x 460mm
Weight 8.8 kg / 19.6 lbs
Innovation , Quality , Performance