ITC Audio T-6223 Quick start guide

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
OPERATION MANUAL
AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
T-6223(A)
ON
OFF
POWER
11 12 13 14 15
12345678910
ALARM ZONES
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VOLUME
5
0
1
2
3
4 6
7
8
9
10
REST
T-6223(A)
MIXER AMPLIFIER
AUDIO
MIXER AMPLIFIER

TABLE OF CONTENTS
2
1. SAFETY PRECAUTIONS ........................................................................................3
2. GENERAL DESCRIPTION .....................................................................................5
3. FEATURES ................................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel .............................................................................................................. 6
4.2 Rear Panel...............................................................................................................7
5.
5.1 User Operation ........................................................................................................8
5.2 .......................................................................................... 8
5.3 ...................................................................................................................... 8
5.4 Address Tag Setup...................................................................................................8
6. APPLICATIONS ......................................................................................................10
7.SPECIFICATIONS ..................................................................................................11
8.DIMENSIONAL DIAGRAM ....................................................................................12
OPERATION
MP3 alarm music player
Rest

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
1. SAFETY PRECAUTIONS

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
ITC
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
SAFETY PRECAUTIONS
4

1.Emergency signal warning function.
2.Warning trigger player automation.
3.Have 30road division warning.
4.30 filed input full automation identify expand to300.
The T-6223(A) is a public address emergency switch with can provide an ideal public address solution from
small to big places such us mosques, schools, hotels and factories to train stadium and air stations.
3. FEATURES
5
2. GENERAL DESCRIPTION

1. POWER
Power indicator
2. POWER SWITCH
On top of the opening Power
Press the end, power shut down
3. ALARM LAYER
Reset button
2
4. ALARM LAYER
Display the working
5. SLAVE
1~30 filed warning indicator
6. VOLUME
Volume control
1
4.1 FRONT PANEL
46
3
5
ON
OFF
POWER
REST
11 12 13 14 15
12345678910
ALARM ZONES
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VOLUME
5
0
1
2
3
4 6
7
8
9
10
4. NOMENCLATURE AND FUNCTIONS
6

10. ADDRESS TAG
Address choose
11. COM
Com communicate point
12. AUDIO SIGNAL OUTPUT
13. SD CARD
14. Status Indicator
When the SD card is running, PLAYING
(green) light, when no SD card, ERRER
(red) light.
15. IN 1~30
1-30 field warning singal input
16. ~220-240V 50/60Hz POWER INPUT
4.2 REAR PANEL
15 16
10 11
COM
ADDRESS
TAG
OUTPUT
LL
RR
SD
ERROR
IN 1-15
IN 16-30
12 13 14
PLAYING
NOMENCLATURE AND FUNCTIONS
7

5.1 USER OPERRATION
5.OPERATION
30 Road fire alarm collection, 30 LED alarm display, as long as short-circuit boards, after
triggering alarm input terminals, you can trigger internal alarms, internal CPU through
the calculations, the alarm signal by RJ422 communications will send out alarm signal,
while playing the corresponding zone alarm music, the corresponding LED display, expand
able to 300 partitions.
5.4 ADDRESS TAG SETUP
1.Address code switch 1-2-3-4 No. 1-4, as
the addresses design of T-6223A
5.2 MP3 ALARM MUSIC PLAYER
When a short circuit alarm signal, the built-in MP3 music player corresponds to alarm through the
alarm signal output will be sent to the amplifier music amplification, when the police lifted, or received
reset signal, the alarm music to stop playing.
1. when the address code is designed to 1, T-6223A is designed to first, MP3 music playback
1-300 zone alarm
2. when the address code designed for 2 pm, T-6223A is designed to second, MP3 players
1-300 area pre-alarm music
3. when the address code designed for 3, T-6223Ais designed to third sets, MP3 playback
signal 1-300 Area undo Music
4. when the address code designed other time, T-6223AZhizuo alarm collection use, built-in
MP3 invalid
Note: SD card MP3 storage method: extended to 300 partition, the SD card root directory need to
build three files, folders, file names are named 1,2,3, each folder must deposit 100 MP3, and
numbered 1-100, when the insufficient number of partitions when the number of MP3, play the
last one, but the MP3 songs in front of 100 is necessary for a storage folder mode
5.3 REST
T-6223A at alarm state, press reset button, you can cancel all of the T-6223Aalarm state, and
stop MP3 playback
8

ADDRESS COAD
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
DIP
DIP
DIP
DIP
ON
ON
ON
ON
1234
DIP ON
1234
DIP ON
1
1
2
2
3
3
4
4
DIP
DIP
ON
ON
ON
ON
WARNING AREA
1-30
151-180
31-60
181-210
61-90
211-240
91-120
241-270
121-150
271-300
1
1
2
2
3
3
4
4
DIP
DIP
ON
ON
ON
ON
OPERATION
2.address code switch 5 NO.5 as a choice of alarm trigger method
3.Address code switch 6-7-8 No. 6 to NO.8 as a design of neighboring alarm
0 aopen-type trigger
1 regular closed Trigger
A normal open short-circuit triggered mode: the methods is to short-circuit the alarm
input port , trigger the alarm, T-6223Awill keep in an alarm status after disconnecting
the alarm input.if want to cancel this status, press reset button directly , also other
machine can send a reset order through the RS422 port to T-6223A
B normal closed short-circuit triggered mode, the method is keep the alarm input port
shorting, trigger the alarm, T-6223Awill discharge the alarm status automatically after
alarm short port disconnecting, through Tung RS422 port, it can send alarm to withdraw
the signal , cancel the corresponding alarm music, also through pressing the third player
to release music music
Neighboring alert data communications sent through the Rj422
000 non-adjacent alarm
001 near police 1
010 adjacent Alarm 2
011 near alarm 3
100 near alarm 4
111 alarm region
9

6. APPLICATIONS
REAR PANEL CONNECTIONS
FIRE ALARM SIGNAL INPUT
COM
ADDRESS
TAG
OUTPUT
LL
RR
SD
ERROR
PLAYING
IN 1-15
IN 16-30
MIXER AMPLIFIER
PAGING SELECTOR
MIC 2
IN
CHIME
VOL ADDRESS COM
ALARM IN(CH1~CH10)
MUSIC IN(CH1~CH10) OUT(CH6~CH10)
OUT(CH1~CH5)
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
++
--
ALARM IN ALARMOUT
+ A - + B - + B -+ A -
+
- -
+
-
+
-
+
LINE1
IN
LINE2
IN
AUDIO
OUT
MIXER AMPLIFIER
MIC2 MIC3
PHANTOM
+48V
PHANTOM
+48V
OUTPUT
COM 4-16 70V 100V
AUX OUT
MUTE EMC INPUT
LINE 1 LINE 2
OFF
ON
OFF
ON
MIC2 MIC3
PHANTOM
+48V
PHANTOM
+48V
OUTPUT
COM 4-16 70V 100V
AUX OUT
MUTE EMC INPUT
LINE 1 LINE 2
OFF
ON
OFF
ON
AUDIO
OUT
R
L
COM
ADRESS TAG
AUDIO SOURCES
SPEAKERS
10

7.SPECIFICATIONS
MODEL
EMERGENCY SWITCH
T-6223(A)
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
484X353X88
POWER CONSUMPTION
POWER REQUIREMENTS
~220-240V 50/60Hz
6.5Kg
5.3Kg
30W
11

100
Over
100
Over
Over
100
8. DIMENSIONAL DIAGRAM
UNIT :mm
6
84
84
25
328
322
88
94
436
484
UNIT :mm
ON
OFF
POWER
REST
11 12 13 14 15
12345678910
ALARM ZONES
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VOLUME
5
0
1
2
3
4 6
7
8
9
10
COM
ADDRESS
TAG
OUTPUT
LL
RR
SD
ERROR
PLAYING
IN 1- 15
IN 16-30
ON
OFF
POWER
REST
11 12 13 14 15
12345678910
ALARM ZONES
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VOLUME
5
0
1
2
3
4 6
7
8
9
10
12

AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
VersionV0.1
This manual suits for next models
1
Table of contents
Other ITC Audio Amplifier manuals

ITC Audio
ITC Audio T-2S01 User manual

ITC Audio
ITC Audio T-30FP User manual

ITC Audio
ITC Audio T-6201 User manual

ITC Audio
ITC Audio TI-60U User manual

ITC Audio
ITC Audio TI-60MT User manual

ITC Audio
ITC Audio T-6601 User manual

ITC Audio
ITC Audio T-20AP User manual

ITC Audio
ITC Audio T-6218 User manual

ITC Audio
ITC Audio TI-60BU User manual

ITC Audio
ITC Audio T-6240B User manual