ITC Audio T-6240B User manual

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
MIXER PRE-AMPLIFIER
T-6240B
OPERATION MANUAL
AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
POWER
T-6240B
MIXER PRE-AMPLIFIER
ON
OFF
MIC
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MICCH 2 CH 3 CH 4 CH 5 CH 6 CH 7
CH 1 CH 8
12
3
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

TABLE OF CONTENTS
T-6240B 2
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel ............................................................................................................ 6
4.2 Rear Panel..............................................................................................................7
5. OPERATING .............................................................................................................8
6. APPLICATIONS .......................................................................................................9
7.SPECIFICATIONS ..................................................................................................10
8.DIMENSIONAL DIAGRAM ....................................................................................11
V1.2-2009-06-03
www.DataSheet.co.kr
Datasheetpdf-http://www.DataSheet4U.net/

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
1. SAFETY PRECAUTIONS
T-6240B
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
ITC
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
4
1. SAFETY PRECAUTIONS
T-6240B
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

5
3. FEATURES
The T-6240B has all the above feature with the addition of two more inputs for a total of eight line level inputs
and one MIC input.
2. GENERAL DESCRIPTION
1. 8 Channels level input,8 Channels output.
2. One MIC input.
3. Two EMC priority inputs.
4. EMC 1 has priority over all inputs (exception MIC 1).
5. Individual channel selectors.
T-6240B
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

4.1 FRONT PANEL
6
1. POWER SWITCH
On top of the opening Power
Press the end, power shut down
2. CH 1~CH8
(CH 1~CH8)Volume controls
3. MIC
MIC Volume controls
4. NOMENCLATURE AND FUNCTIONS
4. MIC
MIC balanced input
5. ON/OFF
MIC priority input switch(CH1~CH8)
6. PRIORITY INDICATORS
MIC priority input indicators
7. POWER
Power indicator
T-6240B
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
POWER
T-6240B
MIXER PRE-AMPLIFIER
ON
OFF
MIC
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MICCH 2 CH 3 CH 4 CH 5 CH 6 CH 7
CH 1 CH 8
1
5
34
2
6
7
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

NOMENCLATURE AND FUCTIONS
7
4.2 REAR PANEL
T-6240B
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
~220V 50Hz
T1AL250V
ON OFF
+48V PHANTOM
CH 1CH 2CH 3
OUTPUT
INTPUT
CH 4
OUTPUT
INTPUT
CH 5
OUTPUT
INTPUT
CH 6
OUTPUT
INTPUT
OUTPUT
INTPUT
OUTPUT
INTPUT
EMC INTPUT
1 2
MIC
XLR BAL
1-GND
2-HOT+
3-COLD
11
22
33
1122
33
OUTPUTS
INPUTS
9
11
8. EMC INPUT
EMC balanced input
9. INPUT (CH1~CH8)
(CH1 ~ CH8) signal input terminal
10.~220V/50Hz AC POWER INPUT
11.AC FUSE
12.OUTPUT (CH1~CH8)
(CH1 ~ CH8) signal output terminal
13.+48V Function Switch
MIC phantasms Power ON / OFF
12
108
13
OUTPUT
INTPUT
OUTPUT
INTPUT
CH 7CH 8
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

8
USAGE WAYS
5. OPERATING
The Pre-Amplifier match between broadcast
Pre-amplifier and broadcast power amplifier,
have emergency broadcast functions. It can
achieve broadcast system 8 areas call's matrix
control functions.
T-6240B
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

6. APPLICATIONS
9T-6240B
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
~220V 50Hz
T1AL250V
ON OFF
+48V PHANTOM
CH 1CH 2CH 3
OUTPUT
INTPUT
CH 4
OUTPUT
INTPUT
CH 5
OUTPUT
INTPUT
CH 6
OUTPUT
INTPUT
OUTPUT
INTPUT
OUTPUT
INTPUT
EMC INTPUT
1 2
MIC
XLR BAL
1-GND
2-HOT+
3-COLD
11
22
33
1122
33
OUTPUTS
INPUTS
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~220V/50Hz
FUSE
F8AL250V
POWER FUSE
350W
500W
650W
F10AL250V
F12AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
Speaker
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~220V/50Hz
FUSE
T8AL250V
POWER FUSE
350W
500W
650W
T10AL250V
T12AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
Speaker POWER AMPLIFIER
POWER AMPLIFIER
R
+ ALARM IN -
MIC LINE ALARM OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
~220V 50Hz
T1AL250V
Emergency alarm input
~220V 50Hz
T1AL250V
AUDIO
OUT
RR
LL
COM
ADRESS TAG
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
R
~220V 50Hz
T1AL250V
AUDIO
OUT
RR
LL
COM
ADRESS TAG
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
R
EMERGENCY PANEL
CD PLAYER
CD PLAYER
OUTPUT
INTPUT
OUTPUT
INTPUT
CH 5CH 6
INTPUT
INTPUT
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

7. SPECIFICATIONS
10
T-6240B
MODEL
PROTECTION
OUTPUT
INPUT
FREQUENCY RESPONSE
S/N
T.H.D
INDICATORS
T-6240B
MIC 5mV/600Ohms,balanced
CH1~CH8 350mV/15KOhms, balanced
EMC(1~2) 350mV/15KOhms, balanced
1V,600 /balanced
20Hz~20KHz
85dB
0.01%
MIC : 80dB;LINE 85dB;MIC 1 priority
EMC1 overrides other input signals(exception MIC 1)
Power LED,MIC channel LEDs
AC fuse:1A
~ 220V AC 50Hz
DIMENSION(mm)
NET WEIGHT
484X353X88
4.3Kg
GROSS WEIGHT 5.8Kg
POWER REQUIREMENTS
POWER CONSUMPTION
CROSSTALK
MUTING FUNCTION
35W
MIXER PRE-AMPLIFIER
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

100
Over
100
Over
Over
100
UNIT :mm
8. DIMENSIONAL DIAGRAM
UNIT :mm
6
84
84
25
328
322
88
94
436
484
11
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
POWER
T-6240B
MIXER PRE-AMPLIFIER
ON
OFF
MIC
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MICCH 2 CH 3 CH 4 CH 5 CH 6 CH 7
CH 1 CH 8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
POWER
T-6240B
MIXER PRE-AMPLIFIER
ON
OFF
MIC
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MICCH 2 CH 3 CH 4 CH 5 CH 6 CH 7
CH 1 CH 8
T-6240B
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
~220V 50Hz
T1AL250V
ON OFF
+48V PHANTOM
CH 1CH 2CH 3
OUTPUT
INTPUT
CH 4
OUTPUT
INTPUT
CH 5
OUTPUT
INTPUT
CH 6
OUTPUT
INTPUT
OUTPUT
INTPUT
OUTPUT
INTPUT
EMC INTPUT
1 2
MIC
XLR BAL
1-GND
2-HOT+
3-COLD
11
22
33
1122
33
OUTPUTS
INPUTS
OUTPUT
INTPUT
OUTPUT
INTPUT
CH 7CH 8
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/

AUDIOAUDIO
Guangzhou ITC Electronic Technology Limited
Http://www.itc-pa.com.cn
PUBLIC ADDRESS SYSTEM
2009-06 Version1.2
www.DataSheet.co.kr
Datasheet pdf - http://www.DataSheet4U.net/
Table of contents
Other ITC Audio Amplifier manuals

ITC Audio
ITC Audio TI-60BU User manual

ITC Audio
ITC Audio T-6601 User manual

ITC Audio
ITC Audio T-30FP User manual

ITC Audio
ITC Audio TI-60U User manual

ITC Audio
ITC Audio T-6218 User manual

ITC Audio
ITC Audio T-2S01 User manual

ITC Audio
ITC Audio T-6201 User manual

ITC Audio
ITC Audio T-6223 Quick start guide

ITC Audio
ITC Audio T-20AP User manual

ITC Audio
ITC Audio TI-60MT User manual