ITC Audio T-218 User manual

Please follow the instructions in this manual to obtain the optimum resultsfrom this unit.
We also recommend that you keep this manual handyfor future reference.
PAGINGMIC CONSOLE
OPERATION MANUAL
AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
T-218

TABLE OFCONTENTS
2
T-218
1. SAFETYPRECAUTIONS .......................................................................................3
2. GENERALDESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATUREAND FUNCTIONS
4.1 Front Panel............................................................................................................. 6
4.2 RearPanel..............................................................................................................7
5.
.5.1 Usage ways............................................................................................................8
5.2 Address codesetting...............................................................................................8
5.3 Broadcastmusic play...............................................................................................8
5.4 Statelight...............................................................................................................8
5.5 Operationattentions................................................................................................8
5.6 Wiringconnection attentions....................................................................................9
5.7 Pagingselector addresscode setting........................................................................9
6. APPLICATIONS .......................................................................................................10
7.SPECIFICATIONS .................................................................................................. 12
8.DIMENSIONAL DIAGRAM ....................................................................................13
OPERATION

Be sure to read the instructions in this sectioncarefully before use.
Make sure to observe the instructions inthis manual as the conventions of safety symbols andmessages
regarded as very important precautions are included.
We also recommend you keep this instructionmanual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
1. SAFETY PRECAUTIONS
T-218

An all-pole mainsswitch with acontact separation ofat least 3mm in eachpole shall beincorporated in
the electrical installationof the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so maycause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed toaccumulate in the unit over a long
periodof time,a fire or damage to the unit may
result.
ITC
If dustaccumulateson thepowersupply plug orin
the wall AC outlet, a fire may result. Clean it
periodically. Inaddition,insert theplugin thewall
outlet securely.
Switchoff the power, andunplug thepower supply
plug from the ACoutlet for safety purposes when
cleaning or leaving theunit unusedfor 10 days or
more.Doingotherwise maycause afire or electric
shock.
1. SAFETY PRECAUTIONS
4
T-218

5
3. FEATURES
2. GENERAL DESCRIPTION
The T-218 is a high performance paging microphone console that works with mixer pre-amplifier(T-6201) and
10-zone speaker selector (T-6212) for emergency notification and remote paging applications.Features include
capability of extension of up to 16 MICS and 160 paging zones, working with 10-zone paging selector. One audio
input and one MIC output. Mute function and built-in chime.
The simple configuration of 10 zones paging system is T-6212 10 zone paging selector works with T-6202 10
zone speaker selector and T-218 remote paging MIC. The max is 160 zones of 16 remote paging MIC T-218 and
16 10 zone paging selector T-6212.
T-218
=All/ten zones.
=1 LINE output , 1 LINE input.
=Chime & MIC function.
=Remote-control available.

6
4. NOMENCLATUREAND FUNCTIONS
4.1 FRONT PANEL
T-218
ADDRESS
CH 6
CH 1
CH 7
CH 2
CH 8
CH 3
CH 9
CH 4
CH 10
CH 5
TEN ZONES ALL ZONES
MIC
MIC ON/OFF CHIME ON
PAGING MIC CONSOLE
T-218
1 2 3 46
58
7109
111213
8. TEN ZONES
Ten zones switch button
9. ALL ZONES
All zones switch indicator
10.TEN ZONES
All zones switch button
11.(CH1~CH10)
Zone switch button
12.(CH1~CH10)
Zone switch indicator
13.MIC
MIC balance input
1. UP/DOWN
2. MIC ON/OFF
. MIC ON/OFF
4. ADDRESS
LED screen
5. CHIME ON
. CHIME ON
Up select button/Down select button
MIC switch indicator
3MIC switch button
Chime state indicator
6Chime triggering button
7. TEN ZONES
Ten zones switch indicator

NOMENCLATURE ANDFUCTIONS
7
14.POWER SWITCH
On top of the opening Power
Press the end, power shut down
15.AC FUSE
16.~220V+/50Hz AC POWER INPUT
17.COM
Remote jack
18.OUTPUT
Line output, Non-equilibrium type, the output of
all input signals.
19.
Line Balanced inputs
20.CHIME VOL
Chime volume control
21.MIC VOL
MIC volume control
LINE IN
4.2 REAR PANEL
14 15
T-218
16 17 18 19 20 21
~220V

8
5.OPERATION
T-218
It will show two deuces plug two digit numbers when
start the machine.
5.1 USAGE WAYS
after two deuces die in 1.5 seconds, it shows one
digit number, it is the zone address code.
Press up and down button to select the number.
1 ZONEBROADCAST
when select , press the console 1-10 zone
to call 1-10 zone.
when select , press the console 1-6 zone to
call 11-16 zone, at the time, console 's 7-10 zone
button can not use.
1
2
2 ALLZONE BROADCAST
No Matter show 1 or 2, press the all zone button,
means 16 zones of the intelligent control center can
broadcast on/off .
Attention:7-10 zonebutton cannot use.
5.2 ADDRESS CODE SETTING
Press all zone button for a while, then start the
machine, it will show as below
At the time, press 1-10 zone button, then it can show
the setting address code as per order, the before time
number as the ten digit of the address code, the input
number as the first digit of the address code.
Press the all zone button to confirm the input address
code.
ATTENTIONS: Address code range as 1-16, if wrong
input, take the last time button number as the standa-
rd.
Such as:
Press No.1zone button,show
Press No.2zone button,show
Press No.3zone button,show
When zone is turned on, line input music will be sent out
automatically.
Press chime button, build-in chime will be sent out auto-
matically.
Press MIC button, start the MIC, then it can broadcast by
MIC.
ATTENTIONS:
1 When chime or MIC is turned on, wire input music will
be mute automatically.
2 When play music, it needs to turn on the Chime and
MIC, then music can be sent out.
1 MIC STATE LIGHT
Light: means MIC is on
Die: means MIC is off
2 CHIME STATE LIGHT
LIGHT: it means Chime music is sending out
Die: it means Chime music is stopped
3 ZONE STATE LIGHT
Light: it means the zone is off
Die: it means the zone is on
Slowly (interval 0.5seconds) flash: it means the current
operation is invalid, the called unit is not exist, or wrong
connection of the control wire.
code consoles processing the on or off operation to the
zone.Quickly (interval 0.5seconds) flash:
it will eliminate all the current states. After press the button,
the light flash, means the current operation is invalid, the
called unit is on the busy state, such as:
The other unit is on the broadcasting, or the localbroadcast,
or on the warning state.
Flash very fast when broadcast, means the called unit has
the priority state broadcast insert.
4 TEN ZONES STATE LIGHT
If the current ten zones are on, ten zones state light will
light automatically, or it will die automatically.
When ten zones state light is lighted, press the button
means turn off the current ten zones, or it means turn on
the current ten zones.
5 ALL ZONE STATE
If all zones are on, all zone light will light automatically, or
it will die automatically.
5.3 BROADCAST MUSIC PLAY
5.4 STATE LIGHT
5.5 OPERATION ATTENTIONS
1Console build-in MPU, turn on/off the internal time should
at least 10 seconds.
2 When connect different unit with Console MIC, please re-
start the machine, or it can't work.
3
When the console connect with the intelligent controller,
then start them, if there is fault for the connection, or the
controller has no power, the console will change to the
state that connect with the paging selector automatically.
4 When the console connect with the intelligent controller,
only the same address code console can process the
synchronous broadcast to the intelligent controller, diffe-
rent address code console turn on the broadcast, the unit
will indicate, the broadcast is busy.
5 Only the console connect with the intelligent controller, the
console address code is useful.

5.OPERATION
5.6 WIRING CONNECTION ATTENTIONS
1
Net wire should adopt STP, RJ45 plug must use the
shielded plug.
2 Net wire two layout shields must connect with metal
shield of the D type Nine Needle Plug.
3 The last two pins of the first row in terminal plug of the
console must connect with the short circuit, or it can
not normal work.
9T-218
Address code
drawing Address code
drawing
The first
from 1~10 The ninth
from 81~90
from 11~20 The tenth
from 91~100
The third
from 21~30 The eleventh
from 101~110
The fourth
from 31~40 The twevle
from 111~120
The fifth
from41~50 The thirteenth
from 121~130
The sixth
from 51~60 The fourteenth
from 131~140
The seventh
from 61~70 The fifteenth
from 141~150
The Eighth
from 71~80 The sixteenth
from 151~160
The second
Definition Definition
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
5.7 PAGING SELECTOR ADDRESS CODE SETTING

6. APPLICATIONS
REAR PANEL CONNECTIONS(1)
The sixteentg
T-218
Connection method Netwire makingmethod
Attention
The first
T-6212
The second
T-218
The first
T-218
The second
T-6212
The sxteentg
T-6212
White orange
Blue
White blown
blown
White orange
Blue
White blown
blown
White orange Blue
White blown
blown
blown
blown
White blown
White blown
Netwire shield layout
ALARM IN
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
ADDRESSTAG
REMOTE OUT
REMOTE IN
CHIME
VOL MIC 2
IN LINE 1
IN LINE 2
IN AUDIO
OUT
~220V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:.
+ A - + B -
ALARM OUT SWITCH OUT
ALARM IN
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
ADDRESSTAG
REMOTE OUT
REMOTE IN
CHIME
VOL MIC 2
IN LINE 1
IN LINE 2
IN AUDIO
OUT
~220V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:.
+ A - + B -
ALARM OUT SWITCH OUT
ALARM IN
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
+ 1 - + 2 - + 3 - + 4 - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 -
ADDRESSTAG
REMOTE OUT
REMOTE IN
CHIME
VOL MIC 2
IN LINE 1
IN LINE 2
IN AUDIO
OUT
~220V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:.
+ A - + B -
ALARM OUT SWITCH OUT
10
T-218

APPLICATIONS
REAR PANEL CONNECTIONS(2)
12345678MP3
910 11 12 13 14 15 16
VOLUME IN
AUDIO IN
AUDIO OUTA
AUDIO OUTB CH1(5A) CH2(5A) CH3(5A) CH4(5A) CH6(5A)CH5(5A)
~220V 50Hz
T0.5AL250V
CF CARD
COM1 COM2 EM
IN EM
OUT TM
OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
T-6600Intelligent controller
The sixteentg
T-218
The second
T-218
The first
T-218
White orange
White blown
Blown
Orange
White orange
White blown
Blown
Orange
White orange
Blue
White blown
Blown
Orange
White blue
White green
Green
Connection method Netwire makingmethod
Netwire shield layout
11 T-218

7.SPECIFICATIONS
MODEL
PROTECTION
OUTPUT
INPUT
FREQUENCY RESPONSE
CROSSTALK
CONTROLS
INDICATORS
PAGINGMIC CONSOLEPAGINGMIC CONSOLE
DIMENSION(mm)
NET WEIGHT
POWER CONSUMPTION
POWER REQUIREMENTS
GROSS WEIGHT
MIC 600Ohms,10mV,Unbalanced
LINE 10KOhms,400mV,Unbalanced
MIC:100Hz~15KHz;LINE: 20Hz~18KHz
MIC input: 80dB;Lineinput: 90dB
Chime MICvol controls,160channel selectors,
Chime button,powe switch
Power LED,10paging channelLEDs
110-120ACor 230-240VAC 50/60Hz 24DC(optional)
ACfuse, 1A
484X360X88
T-218
10W
Balanced
2.2Kg
2.6Kg
12
T-218

8. DIMENSIONALDIAGRAM
13 T-218
50
Over
50
Over
Over
50
UNIT :mm
UNIT :mm
176
144
19
19
144
144
ADDRESS
CH 6
CH 1
CH 7
CH 2
CH 8
CH 3
CH 9
CH 4
CH 10
CH 5
TEN ZONES ALL ZONES
MIC
MIC ON/OFF CHIME ON
PAGING MIC CONSOLE
T-218

AUDIOAUDIO
Guangzhou ITC Electronic Technology Limited
Http://www.itc-pa.com.cn
PUBLIC ADDRESS SYSTEM
2008-03 Version1.1